4.2 Endpoint Descriptor
An Endpoint Descriptor (ED) is a 16-byte, memory resident structure that must be aligned to a 16-byte boundary. The Host Controller traverses lists of EDs and if there are TDs linked to an ED, the Host Controller performs the indicated transfer.
4.2.1 Endpoint Descriptor Format

Notes:
1. Fields containing '—' are not interpreted or modified by the Host Controller and are available
for use by the Host Controller Driver for any purpose.
2. Fields containing '0' must be written to 0 by the Host Controller Driver before queued for
Host Controller processing. If Host Controller has write access to the field, it will always
write the field to 0.
4.2.2 Endpoint Descriptor Field Definitions 

Field Definitions for Endpoint Descriptor
Name HC
Access
Description
FA R FunctionAddress(7Bits,USB地址)
This is the USB address of the function containing the endpoint that this ED controls.
EN R EndpointNumber(4Bits,端点号)
This is the USB address of the endpoint within the function.
D R Direction(方向:IN/OUT)
This 2-bit field indicates the direction of data flow (IN or OUT.) If neither IN nor OUT is specified, then the direction is determined from the PID field of the TD.
The encoding of the bits of this field are:
00 :Get direction From TD
01 :OUT
10 :IN
11 :Get direction From TD
S R Speed(速率:全速/低速)
Indicates the speed of the endpoint: full-speed (S = 0) or low-speed (S = 1.)
K R sKip
When this bit is set, the HC continues on to the next ED on the list without attempting access to the TD queue or issuing any USB token for the endpoint.
F R

Format(链到ED中的TD格式)
This bit indicates the format of the TDs linked to this ED. If this is a Control, Bulk, or Interrupt Endpoint, then F = 0, indicating that the General TD format is used.

If this is an Isochronous Endpoint, then F = 1, indicating that the Isochronous TD format is used.

MPS R MaximumPacketSize(最大Packet的大小)
This field indicates the maximum number of bytes that can be sent to or received from the endpoint in a single data packet.
TailP R TDQueueTailPointer
If TailP and HeadP are the same, then the list contains no TD that the HC can process.
If TailP and HeadP are different, then the list contains a TD to be processed.
H R/W Halted
This bit is set by the HC to indicate that processing of the TD queue on the endpoint is halted, usually due to an error in processing a TD.
C R/W toggleCarry
This bit is the data toggle carry bit. Whenever a TD is retired, this bit is written to contain the last data toggle value (LSb of data Toggle field) from the retired TD.
This field is not used for Isochronous Endpoints.
HeadP R/W TDQueueHeadPointer
Points to the next TD to be processed for this endpoint.
NextED R NextED
If nonzero, then this entry points to the next ED on the list.

 

4.2.3 Endpoint Descriptor Description
Endpoint Descriptors (ED) are linked in lists that are processed by the HC. An ED is linked to a next ED when the NextED field is nonzero.

When the Host Controller accesses an ED, it checks the sKip and the Halted bits to determine if any further processing of the ED is allowed. If either bit is set, then the Host Controller advances to the next ED on the list. If neither the sKip nor the Halted bit is set, then the Host Controller compares HeadP to TailP. If they are not the same, then the TD pointed to by HeadP defines a buffer to/from which the Host Controller will transfer a data packet.

This linking convention assumes that the Host Controller Driver queues to the 'tail' of the TD queue. It does this by linking a new TD to the TD pointed to by TailP and then updating TailP to point to the TD just added.
When processing of a TD is complete, the Host Controller 'retires' the TD by unlinking it from the ED and linking it to the Done Queue. When a TD is unlinked, NextTD of the TD is copied to HeadP of the ED.

The sKip bit is set and cleared by the Host Controller Driver when it wants the Host Controller to skip processing of the endpoint. This may be necessary when the Host Controller Driver must modify the value of HeadP and the overhead of removing the ED from its list is prohibitive.

The Halted bit is set by the Host Controller when it encounters an error in processing a TD. When the TD in error is moved to the Done Queue, the Host Controller updates HeadP and sets the Halted bit, causing the Host Controller to skip the ED until Halted is cleared. The Host Controller Driver clears the Halted bit when the error condition has been corrected and transfers to/from the endpoint should resume. The Host Controller Driver should not write to HeadP/toggleCarry/Halted unless Halted is set, sKip is set, or the ED has been removed from the list.

When TDs are queued to an ED, the Host Controller processes the TDs asynchronously with respect to processing by the host processor. Therefore, if the Host Controller Driver needs to alter the TD queue other than appending to the queue, it must stop the Host Controller from processing the TD queue for the endpoint so that changes can be made. The nominal mechanisms for stopping TD processing are for the Host Controller Driver to remove the ED from the list or to set the sKip bit in the ED.

When the D field of an ED is 10b (IN), the Host Controller may issue an IN token to the specified endpoint after it determines that HeadP and TailP are not the same. This indicates that a buffer exists for the data and that input of the endpoint data may occur in parallel with the HC's access of the TD which defines the memory buffer.

Since an ED must be aligned to a 16-byte boundary, the Host Controller only uses the upper 28 bits of Dword3 as a pointer to the next ED. TailP and HeadP point to TDs which may be either 16- or 32-byte aligned. The Host Controller uses only the upper 28 bits of Dword1 and Dword2 to point to a 16-byte aligned TD (F = 0). If HeadP and TailP point to a TD that must be 32-byte aligned (F = 1), then bit 4 of these Dwords must be 0.

 