当配置多个VLan时候,在鍵入exit或apply时候经常会出现下面的出错信息,使得无法创建新的vlan

  SW1(vlan)#exit

  % not enough space on flash to store vlan database. trying s queeze...First create squeeze log by erasing the entire device

  % error squeezing flash - (Missing or corrupted log)

  Error on database apply 40: NV storage failure

  Use 'abort' command to exit  

  SW1(vlan)#

  sw1#erase flash:

   Erasing the flash filesystem will remove all files! Continue? [confirm]

  Erasing device... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee ...erased

  Erase of flash: complete

  解决办法:出现错误时候,鍵入abort先退到特权模式,然后打入erase flash,点确定完,再进入vlan database配置VLan即可。

posted on 2011-07-04 02:43  默斋  阅读(1715)  评论(0编辑  收藏  举报