关于multicycle path

SLOW-to-FAST

默认情况下检查的是:

 

 

 如果只设setup的multicycle path,即

set_multicycle_path 2 -setup -end -from CLK1 -to CLK2

 

 

 如果setup/hold都是默认的setup用end,hold用start,即(错误的)

set_multicycle_path 2 -setup -end -from CLK1 -to CLK2

set_multicycle_path 1 -hold -start -from CLK1 -to CLK2

 

 

 正确的设置应该是:

set_multicycle_path 2 -setup -end -from CLK1 -to CLK2

set_multicycle_path 1 -hold -end -from CLK1 -to CLK2

 

 即对于hold,-start是将start clock像向后移,-end是将end clock向前移

FAST-to-SLOW

默认情况下检查的是:

 

如果只setup multicyle

set_multicycle_path 2 -setup -start -from CLK1 -to CLK2

 正确的设置应该是:

set_multicycle_path 2 -setup -start -from CLK1 -to CLK2

set_multicycle_path 1 -hold -start -from CLK1 -to CLK2

 

 即对于setup,-start是将start clock像向前移,-end是将end clock向后移

 

 

 

To set a multicycle maximum path, you can either move the end clock forward or
the start clock backward. To set a multicycle minimum path, you can either move
the end clock backward or the start clock forward. You control the movement by
using the -end and -start switches. By default, set_multicycle_path moves the
end clock for the max path and the start clock for the min path. For a single
clock domain path, there is no need to specify the -end or -start option (it
has no effect). But for a crossing domain path, moving the start clock forward
one cycle is not equal to moving the end clock backward one cycle. The different
options give totally different timing windows.

posted on 2020-01-14 16:26  yiyedada  阅读(3225)  评论(0编辑  收藏  举报

导航