DELL硬件监控(omreport)
DELL硬件监控(omreport)
omreport: omsa报告
显示已经安装的硬件设备的数字许可证(就是显示idrac的一些信息)
./omreport licenses
Licenses information
Device Index : 0
Device Status : Ok
Device : iDRAC
Device Description : iDRAC8
Device ID : 25F6YM2
License Index : 0
Description : iDRAC8 Enterprise License
Status : OK
Recommended Action : N/A
License Type : Perpetual
Entitlement ID : FD00000010160082
Expiry Date : N/A
报告系统偏好信息的配置(在这里我们公司是没有进行配置的所以都是空)
./omreport preferences
- 事件日志
这里的都是日志,不是硬件的实时状态
./omreport system alertlog
Alert Log
Alert Log contains...
Severity : Critical # 状态 # 就像这个就说明在A11的内存位置上有位错误
ID : 1404 # 事件id
Date and Time : Mon Aug 12 14:26:00 2019 # 事件发生的时间
Category : Instrumentation Service
Description : Memory device status is critical # 说明
Memory device location: A11 # 设备位置
Possible memory module event cause:Multi bit error encountered # 问题说明
Severity : Ok
ID : 2415
Date and Time : Sun Dec 15 20:15:06 2019
Category : Storage Service
Description : Controller battery is discharging: Battery 0 Controller 0
Severity : Ok
ID : 2243
Date and Time : Sat Dec 14 12:58:00 2019
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H730 Mini)
Severity : Ok
ID : 2242
Date and Time : Sat Dec 14 11:00:54 2019
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H730 Mini)
Severity : Ok
ID : 2243
Date and Time : Sat Dec 7 13:20:27 2019
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H730 Mini)
Severity : Ok
ID : 2242
Date and Time : Sat Dec 7 11:00:53 2019
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H730 Mini)
Severity : Ok
ID : 1000
Date and Time : Mon Aug 12 14:23:39 2019
Category : Instrumentation Service
Description : Server Administrator starting
Severity : Ok
ID : 1012
Date and Time : Mon Aug 12 14:23:39 2019
Category : Instrumentation Service
Description : IPMI status
Interface: OS
Severity : Ok
ID : 1001
Date and Time : Mon Aug 12 14:23:39 2019
Category : Instrumentation Service
Description : Server Administrator startup complete
- 资产信息展示
./omreport system assetinfo
Summary of Asset Information
-------------
Acquisition
-------------
Purchase Cost : 0
Reference to Delivery Slip number (Way Bill) : 0
Reference to PO number : 0
Who Signed for : Please set the value
Installation Date : Please set the value
Purchase Date : Please set the value
Vendor : Dell
Expensed : Yes
Cost Center : Please set the value
--------------
Depreciation
--------------
Method : Please set the value
Duration : 0
Duration Unit Type : Months
Percentage : 0
-------------------
Extended Warranty
-------------------
Cost : 0
Provider : Please set the value
Start Date : Please set the value
End Date : Please set the value
-------
Lease
-------
Multiple Schedules : No
Buyout Amount : 0
Rate Factor : 0
End Date : Please set the value
Fair Market Value : 0
Lessor : Please set the value
-------------
Maintenance
-------------
Provider : Please set the value
Restrictions : Please set the value
Start Date : Please set the value
End Date : Please set the value
-----------
Outsource
-----------
Problem Component : Please set the value
Service Fee : Please set the value
Who Signed for : Please set the value
Provider Fee : Please set the value
SLA Level : Please set the value
---------
Support
---------
Outsourced : No
Type : Network
Help Desk : Please set the value
Automatic Fix : Please set the value
------------------
Service Contract
------------------
Renewed : No
Type : Please set the value
Vendor : Please set the value
----------
Warranty
----------
Duration : 0
Unit Type : Days
End Date : Please set the value
Cost : 0
--------
System
--------
System Bootup Time : Mon Mar 11 17:58:40 2019
System Time : Tue Feb 4 19:07:32 2020
System Name : node28.blistack.ops.beta.bj1.wormpex.com
System Location : Please set the value
Primary User Name : Please set the value
Primary User Telephone Number : Please set the value
-------
Owner
-------
Type : Owned
Owner Name : Please set the value
Insurance Company : Please set the value
嵌入式日志管理系统日志展示
这里的信息和下图的信息是一致的
./omreport system esmlog
Embedded System Management (ESM) Log
Health : Ok
Severity : Ok
Date and Time : Fri Jul 20 19:07:11 2018
Description : Log cleared.
Severity : Non-Critical
Date and Time : Wed Aug 1 11:00:14 2018
Description : Correctable memory error rate exceeded for DIMM_B7.
Severity : Critical
Date and Time : Wed Aug 1 11:00:40 2018
Description : Correctable memory error rate exceeded for DIMM_B7.
.....
- 显示该设备的基础信息
./omreport system summary
System Summary
------------------
Software Profile
------------------
Systems Management # 这下边的信息是omsa的软件版本信息
Name : Dell OpenManage Server Administrator
Version : 8.2.0
Description : Systems Management Software
Contains : Data Engine 8.2.0
: Data Engine SNMP 8.2.0
: Disney SNMP 8.2.0
: Hardware Abstraction Programming Interface 8.2.0
: Instrumentation Services 8.2.0
: Meta package for installing the Server Administrator Storage Services feature 8.2.0
: Meta package for installing the Server Administrator storage cli component 8.2.0
: Meta package for installing the Server Administrator storage snmp component 8.2.0
: Meta package for installing the Server Agent 8.2.0
: NVMe Library 8.2.0
: OpenManage Inventory Collector 8.2.0
: RealSSD package for storage management 8.2.0
: Remote Access Card Data Populator 8.2.0
: Server Administrator CLI 8.2.0
: Server Administrator Common Framework 8.2.0
: Server Administrator Common Services 8.2.0
: Server Administrator Core 8.2.0
: Server Administrator XML Support SDK 8.2.0
: Storage Management CLI component 5.2.0
: Storage Management SNMP component 5.2.0
: Storage Management System Utilities Package / Libsysfs 1.3.0
: Storage Management accessors package 5.2.0
: Storage Management common files for GUI and CLI 5.2.0
: StoreLib package for storage management 8.2.0
: System Utilities Package/Libsysfs for LSI storage libraries 2.1.0
: iDRAC SNMP components 8.2.0
Operating System
Name : CentOS Linux
Version : release 7.4.1708 (Core) Kernel 3.10.0-693.el7.x86_64 (x86_64)
System Time : Tue Feb 4 19:13:42 2020
System Bootup Time : Mon Mar 11 17:58:40 2019
--------
System
--------
System
Host Name : node28.blistack.ops.beta.bj1.wormpex.com # 这个是主机名
System Location : Please set the value
Lifecycle Controller : Enabled
---------------------
Main System Chassis
---------------------
Chassis Information
Chassis Model : PowerEdge R730 # 型号
Chassis Service Tag : 25F6YM2 # sn号
Express Service Code : 4681414586 # 快速服务代码
Chassis Lock : Present
Chassis Asset Tag : Unknown
Node Id : 25F6YM2 # sn号
Remote Access Information
Remote Access Device : iDRAC8 Enterprise
vFlash Media : Absent
# cpu相关的信息
Processor 1
Processor Brand : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Processor Version : Model 79 Stepping 1
Voltage : 1300 mV
Processor 2
Processor Brand : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Processor Version : Model 79 Stepping 1
Voltage : 1300 mV
# 内存相关的信息
Memory
Total Installed Capacity : 393216 MB
Memory Available to the OS : 386690 MB
Total Maximum Capacity : 3145728 MB
Memory Array Count : 1
Memory Array 1
Location : System Board or Motherboard
Use : System Memory
Installed Capacity : 393216 MB
Maximum Capacity : 2097152 MB
Slots Available : 24
Slots Used : 24
ECC Type : Multibit ECC
# pci插槽相关信息
Slot PCIe Slot 1
Adapter : [Not Occupied]
Type : PCI E Gen 3 X16
Data Bus Width : 8x or x8
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
Slot PCIe Slot 2
Adapter : [Not Occupied]
Type : PCI E Gen 3 X16
Data Bus Width : 8x or x8
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
Slot PCIe Slot 3
Adapter : [Not Occupied]
Type : PCI E Gen 3 X16
Data Bus Width : 8x or x8
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
Slot PCIe Slot 4
Adapter : [Not Occupied]
Type : PCI E Gen 3
Data Bus Width : 16x or x16
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
Slot PCIe Slot 5
Adapter : Intel(R) 10GbE 2P X520 Adapter
Type : PCI E Gen 3 X16
Data Bus Width : 8x or x8
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
Slot PCIe Slot 6
Adapter : [Not Occupied]
Type : PCI E Gen 3 X16
Data Bus Width : 8x or x8
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
Slot PCIe Slot 7
Adapter : [Not Occupied]
Type : PCI E Gen 3 X16
Data Bus Width : 8x or x8
Speed : [Not Obtained, see card documentation]
Slot Length : Long
Voltage Supply : 3.3 Volts
# bios信息其实就是版本
BIOS Information
Manufacturer : Dell Inc.
Version : 2.9.1
Release Date : 12/04/2018
# idrac相关信息其实就是版本号
Firmware Information
Name : iDRAC8
Version : 2.50.50.50 (Build 33)
Firmware Information
Name : Lifecycle Controller
Version : 2.50.50.50
# ipmi配置的地址网关
--------------------------
Remote Access Controller
--------------------------
Remote Access Controller Information
Product : iDRAC8 Enterprise
IP Address : 10.252.200.11
IP Subnet : 255.255.255.0
IP Gateway : 10.252.200.254
IPv6 Address 1 : ::
IPv6 Address 2 : ::
IPv6 Gateway : ::
# 机器上的网卡的基本信息
--------------
Network Data
--------------
Network Interface 0
IP Address : [No Value]
MAC Address : 80:18:44:F0:EA:9C
Network Interface 1
IP Address : [No Value]
MAC Address : 80:18:44:F0:EA:9D
Network Interface 2
IP Address : [No Value]
MAC Address : 80:18:44:F0:EA:9E
Network Interface 3
IP Address : [No Value]
MAC Address : 80:18:44:F0:EA:9F
Network Interface 4
IP Address : [No Value]
MAC Address : B4:96:91:1F:8F:90
Network Interface 5
IP Address : [No Value]
MAC Address : B4:96:91:1F:8F:92
Team Interface 0
IP Address : [No Value]
MAC Address : B4:96:91:1F:8F:90
Team Interface 1
IP Address : [No Value]
MAC Address : D6:A9:1A:D4:4A:4A
Team Interface 2
IP Address : [No Value]
MAC Address : 0A:3E:97:8F:21:89
Team Interface 3
IP Address : 10.253.200.11
Subnet Mask : 255.255.255.192
Default Gateway : 10.253.200.62
MAC Address : 7E:14:9E:9D:45:A0
--------------------
Storage Enclosures
--------------------
Storage Enclosures
Name : Backplane
- 电源监控相关输出
一般的服务的电源都是双电源
./omreport chassis pwrmonitoring
Power Consumption Information
Power Consumption
Index : 2
Status : Ok # 这里是状态
Probe Name : System Board Pwr Consumption
Reading : 294 W # 这里是当前的渎职
Warning Threshold : 896 W # 这个是警告的阈值,可以通过omconfig进行修改
Failure Threshold : 980 W # 这个是故障的阈值,可以通过omconfig进行修改
Amperage # 俩个电源当前的消费A数
PS1 Current 1 : 1.4 A
PS2 Current 2 : 0.2 A
Power Headroom
System Instantaneous Headroom : 595 W
System Peak Headroom : 534 W
Power Tracking Statistics # 这个是从统计开始时间到统计结束时间所使用的电源总计
Statistic : Energy Consumption
Measurement Start Time : Sun Dec 24 15:04:00 2017
Measurement Finish Time : Tue Feb 4 19:22:14 2020
Reading : 4528.2 kWh
Statistic : System Peak Power # 这里统计了使用的峰值w
Measurement Start Time : Sun Dec 24 15:04:01 2017
Peak Time : Tue Feb 4 16:18:39 2020
Peak Reading : 366 W
Statistic : System Peak Amperage # 使用的峰值 A
Measurement Start Time : Sun Dec 24 15:04:01 2017
Peak Time : Thu Sep 19 15:37:05 2019
Peak Reading : 2.2 A
- 输出当前的bios的配置
./omreport chassis biossetup
Operation is under progress, it may take few seconds to complete...
Note: use display=shortnames optional parameter to see attribute names and setting values in short form.
BIOS Setup
System Information
------------------------------------------
System Model Name : PowerEdge R730
System BIOS Version : 2.9.1
System Management Engine Version : 3.1.3.38
System Service Tag : 25F6YM2
System Manufacturer : Dell Inc.
System Manufacturer Contact Information : www.dell.com
System CPLD Version : 1.0.1
UEFI Compliance Version : 2.4
Memory Settings
------------------------------------------
System Memory Size : 384 GB
System Memory Type : ECC DDR4
System Memory Speed : 1866 Mhz
System Memory Voltage : 1.20 V
Video Memory : 16 MB
System Memory Testing : Disabled
Memory Operating Mode : Optimizer Mode
Node Interleaving : Disabled
Snoop Mode : Opportunistic Snoop Broadcast
Correctable Memory ECC SMI : Enabled
Processor Settings
------------------------------------------
Logical Processor : Enabled
QPI Speed : Maximum data rate
QPI Link L1 Power Management : Enabled
Alternate RTID (Requestor Transaction ID) Setting : Disabled
Virtualization Technology : Enabled
Address Translation Services (ATS) : Enabled
Adjacent Cache Line Prefetch : Enabled
Hardware Prefetcher : Enabled
DCU Streamer Prefetcher : Enabled
DCU IP Prefetcher : Enabled
Execute Disable : Enabled
Logical Processor Idling : Disabled
Configurable TDP : Nominal
X2Apic Mode : Disabled
Dell Controlled Turbo : Disabled
Number of Cores per Processor : All
Processor 64-bit Support : Yes
Processor Core Speed : 2.20 GHz
Processor Bus Speed : 8.0 GT/s
Family-Model-Stepping : 6-4F-1
Brand : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Level 2 Cache : 10x256 KB
Level 3 Cache : 25 MB
Number of Cores : 10
Microcode : 0xB000033
Family-Model-Stepping : 6-4F-1
Brand : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Level 2 Cache : 10x256 KB
Level 3 Cache : 25 MB
Number of Cores : 10
Microcode : 0xB000033
SATA Settings
------------------------------------------
Embedded SATA : AHCI Mode
Security Freeze Lock : Enabled
Write Cache : Disabled
Port A : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port B : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port C : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port D : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port E : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port F : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port G : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port H : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port I : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Port J : Auto
Model : Unknown
Drive Type : Unknown Device
Capacity : N/A
Boot Settings
------------------------------------------
Boot Mode : BIOS
Boot Sequence Retry : Enabled
Hard-Disk Failover : Disabled
BIOS Boot Settings
------------------------------------------
Boot Sequence
: 0. Enabled: Hard drive C:
: 1. Enabled: NIC in Slot 5 Port 1 Partition 1: IBA XE Slot 0600 v2390
: 2. Enabled: NIC in Slot 5 Port 2 Partition 1: IBA XE Slot 0601 v2390
Hard-Disk Drive Sequence
: 0. Integrated RAID Controller 1: PERC H730 Mini(bus 03 dev 00)
One-Time Boot
------------------------------------------
One-Time Boot Device List : Disabled
BIOS Boot Sequence Device : NIC in Slot 5 Port 1 Partition 1: IBA XE Slot 0600 v2390
BIOS Hard-Disk Drive Sequence Device : Integrated RAID Controller 1: PERC H730 Mini(bus 03 dev 00)
Integrated Devices
------------------------------------------
USB 3.0 Setting : Disabled
User Accessible USB Ports : All Ports On
Internal USB Port : On
Integrated RAID Controller : Enabled
Integrated Network Card 1 : Enabled
Integrated Network Card 1 Port 1 Boot Protocol : None
Integrated Network Card 1 Port 2 Boot Protocol : None
Integrated Network Card 1 Port 3 Boot Protocol : None
Integrated Network Card 1 Port 4 Boot Protocol : None
I/OAT DMA Engine : Disabled
I/O Non-Posted Prefetch : Enabled
I/O Snoop HoldOff Response : 256 Cycles
Embedded Video Controller : Enabled
Current State of Embedded Video Controller : Enabled
SR-IOV Global Enable : Disabled
OS Watchdog Timer : Disabled
Memory Mapped I/O above 4GB : Enabled
Lower Memory Mapped I/O Base to 512G : Disabled
Slot Disablement
------------------------------------------
Global Slot Boot Driver Disable : Disabled
Slot 1 : Enabled
Slot 2 : Enabled
Slot 3 : Enabled
Slot 4 : Enabled
Slot 5 : Enabled
Slot 6 : Enabled
Slot 7 : Enabled
Slot Bifurcation
------------------------------------------
Slot 1 Bifurcation : Default Bifurcation
Slot 2 Bifurcation : Default Bifurcation
Slot 3 Bifurcation : Default Bifurcation
Slot 4 Bifurcation : Default Bifurcation
Slot 5 Bifurcation : Default Bifurcation
Slot 6 Bifurcation : Default Bifurcation
Slot 7 Bifurcation : Default Bifurcation
Serial Communication
------------------------------------------
Serial Communication : Auto
Serial Port Address : Serial Device1=COM2,Serial Device2=COM1
External Serial Connector : Serial Device 1
Failsafe Baud Rate : 115200
Remote Terminal Type : VT100/VT220
Redirection After Boot : Enabled
System Profile Settings
------------------------------------------
System Profile : Performance
CPU Power Management : Maximum Performance
Memory Frequency : Maximum Performance
Turbo Boost : Enabled
Energy Efficient Turbo : Disabled
C1E : Disabled
C States : Disabled
Write Data CRC : Disabled
Collaborative CPU Performance Control : Disabled
Memory Patrol Scrub : Standard
Memory Refresh Rate : 1x
Uncore Frequency : Maximum
Energy Efficient Policy : Performance
Number of Turbo Boost Enabled Cores for Processor 1 : All
Number of Turbo Boost Enabled Cores for Processor 2 : All
Monitor/Mwait : Enabled
Workload Profile : Not Available
Power Saver : Disabled
System Security
------------------------------------------
Intel(R) AES-NI : Enabled
System Password :
Setup Password :
Password Status : Unlocked
TPM Information : No TPM present
TPM Status : Unknown
Intel(R) TXT : Off
AC Power Recovery : Last
AC Power Recovery Delay : Immediate
User Defined Delay (60s to 240s) : 60
UEFI Variable Access : Standard
Secure Boot : Disabled
Secure Boot Policy : Standard
Miscellaneous Settings
------------------------------------------
Asset Tag :
Keyboard NumLock : On
F1/F2 Prompt on Error : Enabled
Load Legacy Video Option ROM : Disabled
In-System Characterization : Disabled
- bmc相关信息输出
./omreport chassis bmc
Remote Access Information
Remote Access Device
Device Type : iDRAC8 Enterprise
iDRAC Ports : Present
IPMI Version : 2.0
System GUID : 324d594f-c0b2-3680-4610-00354c4c4544
Number of Possible Active Sessions : 5
Number of Current Active Sessions : 0
Enable IPMI Over LAN : Yes
SOL Enabled : Yes
MAC Address : 50-9A-4C-79-96-BD
IPv4 Address
IP Address Source : Static
IP Address : 10.252.200.11
IP Subnet : 255.255.255.0
IP Gateway : 10.252.200.254
- 风扇详细信息
./omreport chassis fans
Index : 5 # id
Status : Ok # 状态,这个状态是根据报警阈值进行区分的
Probe Name : System Board Fan6 # 风扇名称
Reading : 4560 RPM # 当前的读取值
Minimum Warning Threshold : 600 RPM # 警告报警值
Maximum Warning Threshold : [N/A]
Minimum Failure Threshold : 360 RPM # 故障报警值
Maximum Failure Threshold : [N/A]
- 传感器有插槽详细信息
./omreport chassis fru
System Components (FRU) Information
# 管理卡设备
Device : System Planar (iDRAC8)
Serial No. : CNWS3007C4000G
Part No. : 0WCJNT
Revision : A08
Manufacturer : DELL
Manufacture Date : Tue Dec 05 07:08:00 2017
# 电源设备
Device : Power Supply 1 (PS1)
Serial No. : PHARP007A600ZD
Part No. : 0PJMDN
Revision : A01
Manufacturer : DELL
Manufacture Date : Fri Oct 06 15:30:00 2017
Device : Power Supply 2 (PS2)
Serial No. : PHARP007A600ZB
Part No. : 0PJMDN
Revision : A01
Manufacturer : DELL
Manufacture Date : Fri Oct 06 15:29:00 2017
Device : Disk Drive Bay (BP1)
Serial No. : CNFCP007BM00AI
Part No. : 07K5HK
Revision : A01
Manufacturer : DELL
Manufacture Date : Thu Nov 30 09:59:00 2017
Device : Add-in Card (NDC)
Serial No. : CN7361479T04LP
Part No. : 0FM487
Revision : A06
Manufacturer : DELL
Manufacture Date : Sat Sep 29 00:00:00 2007
Device : Add-in Card (PERC1)
Serial No. : CNFCP007BN02H8
Part No. : 0KMCCD
Revision : A08
Manufacturer : DELL
Manufacture Date : Fri Nov 24 17:43:00 2017
Device : A1
Serial No. : 2B3DC481
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A2
Serial No. : 2B3DC670
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A3
Serial No. : 2B3DC565
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A4
Serial No. : 2B3DC63A
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A5
Serial No. : 2B3DC6AB
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A6
Serial No. : 2B3DC417
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A7
Serial No. : 2B3DC648
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
Device : A8
Serial No. : 2B3DC55F
Part No. : HMA82GR7AFR8N-UH
Revision : N/A
Manufacturer : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
- 内存详细信息
./omreport chassis memory
Index : 23 # id
Status : Ok # 状态
Connector Name : B12 # 槽位
Type : DDR4 - Synchronous Registered (Buffered)
Size : 16384 MB # 大小
- 网络接口卡详细信息
./omreport chassis nics
Network Interfaces Information
# 物理接口
Physical NIC Interface(s)
Index : 0
Interface Name : eth0 # 接口名称
Vendor : Broadcom Corporation
Description : NetXtreme BCM5720 Gigabit Ethernet PCIe
Connection Status : Disabled
Slot : Embedded
...
# 虚拟接口
Team Interface(s)
Index : 0
Interface Name : br-bond0
Vendor : CentOS Linux
Description : Virtual Switch
Redundancy Status : Not Applicable
...
- 端口属性信息
./omreport chassis ports
Port Type : USB
External Name : Front USB port 2
Base I/O Addr :
IRQ Lvl :
Connector Type : Access Bus (USB)
Maximum Speed :
- 处理器信息
./omreport chassis processors
Health : Ok
Index : 0 # id
Status : Ok # 健康状态
Connector Name : CPU1 # 名称
Processor Brand : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz # 型号
Processor Version : Model 79 Stepping 1
Current Speed : 2200 MHz
State : Present
Core Count : 10
Index : 1
Status : Ok
Connector Name : CPU2
Processor Brand : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Processor Version : Model 79 Stepping 1
Current Speed : 2200 MHz
State : Present
Core Count : 10
- 电源状态信息
./omreport chassis pwrsupplies
Power Supplies Information
Power Supply Redundancy
Redundancy Status : Full
Individual Power Supply Elements
Index : 0 # id
Status : Ok # 状态
Location : PS1 Status # 位置
Type : AC
Rated Input Wattage : 900 W # 输入
Maximum Output Wattage : 750 W # 输出
Firmware Version : 00.1B.53
Online Status : Presence Detected # 线上状态
Power Monitoring Capable : Yes
Index : 1
Status : Ok
Location : PS2 Status
Type : AC
Rated Input Wattage : 900 W
Maximum Output Wattage : 750 W
Firmware Version : 00.1B.53
Online Status : Presence Detected
Power Monitoring Capable : Yes
- pci插槽状态
./omreport chassis slots
Slots Information
这里可以看到slots的状态
Index : 0
Slot ID : PCIe Slot 1 # 插槽id
Adapter : [Not Occupied]
Data Bus Width : 8x or x8 # 就像这个是总线插槽大小
Index : 3
Slot ID : PCIe Slot 4
Adapter : [Not Occupied]
Data Bus Width : 16x or x16
Index : 4 # 就像是这个就是查了一个万兆网卡
Slot ID : PCIe Slot 5
Adapter : Intel(R) 10GbE 2P X520 Adapter
Data Bus Width : 8x or x8
Index : 5
Slot ID : PCIe Slot 6
Adapter : [Not Occupied]
Data Bus Width : 8x or x8
Index : 6
Slot ID : PCIe Slot 7
Adapter : [Not Occupied]
Data Bus Width : 8x or x8
Index : 7 # 这个是插来 千兆网卡
Slot ID : Embedded
Adapter : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A
Index : 8
Slot ID : Embedded
Adapter : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A
Index : 9
Slot ID : Embedded
Adapter : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A
Index : 10
Slot ID : Embedded
Adapter : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A
Index : 11
Slot ID : Embedded
Adapter : PERC H730 Mini
Data Bus Width : N/A
Index : 12
Slot ID : Embedded
Adapter : G200eR2
Data Bus Width : N/A
Index : 13 # usb的设备
Slot ID : Embedded
Adapter : C610/X99 series chipset USB Enhanced Host Controller #1
Data Bus Width : N/A
Index : 14
Slot ID : Embedded
Adapter : C610/X99 series chipset USB Enhanced Host Controller #2
Data Bus Width : N/A
- 系统主要的温度相关的数据
./omreport chassis temps
Temperature Probes Information
------------------------------------
Main System Chassis Temperatures: Ok
------------------------------------
Index : 0
Status : Ok
Probe Name : System Board Inlet Temp # 指标的名称
Reading : 26.0 C # 当前的读取的值
Minimum Warning Threshold : 3.0 C # 这里就是报警的阈值可以使用omconfig修改
Maximum Warning Threshold : 42.0 C
Minimum Failure Threshold : -7.0 C
Maximum Failure Threshold : 47.0 C
Index : 1
Status : Ok
Probe Name : System Board Exhaust Temp
Reading : 38.0 C
Minimum Warning Threshold : 0.0 C
Maximum Warning Threshold : 70.0 C
Minimum Failure Threshold : 0.0 C
Maximum Failure Threshold : 75.0 C
Index : 2
Status : Ok
Probe Name : CPU1 Temp
Reading : 45.0 C
Minimum Warning Threshold : 8.0 C
Maximum Warning Threshold : 85.0 C
Minimum Failure Threshold : 3.0 C
Maximum Failure Threshold : 90.0 C
Index : 3
Status : Ok
Probe Name : CPU2 Temp
Reading : 50.0 C
Minimum Warning Threshold : 8.0 C
Maximum Warning Threshold : 85.0 C
Minimum Failure Threshold : 3.0 C
Maximum Failure Threshold : 90.0 C
- 各个插槽的电压状态属性
./omreport chassis volts
Voltage Probes Information
Health : Ok
Index : 0
Status : Ok # 状态
Probe Name : CPU1 VCORE PG # 指标名称
Reading : Good # 读取的值
Minimum Warning Threshold : [N/A] # 因为这个电压的状态值只有有值和没有值俩个,所以没有阈值说法
Maximum Warning Threshold : [N/A]
Minimum Failure Threshold : [N/A]
Maximum Failure Threshold : [N/A]
- 系统版电池状态(纽扣电池)
./omreport chassis batteries
Batteries
Health : Ok
Individual Battery Elements
Index : 0
Status : Ok
Probe Name : System Board CMOS Battery
Reading : Good
- 物理磁盘设备
./omreport storage pdisk controller=0
ID : 0:1:13 # 设备id
Status : Ok # 状态 这个是判断磁盘状态的值
Name : Physical Disk 0:1:13 # 物理设备名称
State : Online # 当前的状态
Power Status : Spun Up # 电源状态
Bus Protocol : SAS # 总线协议
Media : HDD
Part of Cache Pool : Not Applicable
Remaining Rated Write Endurance : Not Applicable
Failure Predicted : No
Revision : KT37
Driver Version : Not Applicable
Model Number : Not Applicable
T10 PI Capable : No
Certified : Yes
Encryption Capable : No
Encrypted : Not Applicable
Progress : Not Applicable
Mirror Set ID : Not Applicable
Capacity : 558.38 GB (599550590976 bytes) # 磁盘大小
Used RAID Disk Space : 558.38 GB (599550590976 bytes)
Available RAID Disk Space : 0.00 GB (0 bytes)
Hot Spare : No # 是否热备
Vendor ID : DELL(tm) # 厂商设备id,这个是要返回出来
Product ID : ST600MP0036
Serial No. : WAF0E9BK
Part Number : CN0FPW68SGW007BU01PNA01
Negotiated Speed : 12.00 Gbps
Capable Speed : 12.00 Gbps
PCIe Negotiated Link Width : Not Applicable
PCIe Maximum Link Width : Not Applicable
Sector Size : 512B
Device Write Cache : Not Applicable
Manufacture Day : 06
Manufacture Week : 48
Manufacture Year : 2017
SAS Address : 5000C500A1228CF1
Form Factor : Not Available
Sub Vendor : Not Available
- 虚拟磁盘状态
可以看到这里有俩个阵列,一个是raid1 和raid5
./omreport storage vdisk controller=0
List of Virtual Disks on Controller PERC H730 Mini (Embedded)
Controller PERC H730 Mini (Embedded)
ID : 0 #
Status : Ok # 整列状态
Name : Virtual Disk0
State : Ready
Hot Spare Policy violated : Not Assigned
Encrypted : No
Layout : RAID-1 # raid级别
Size : 278.88 GB (299439751168 bytes) # 整列的大小
T10 Protection Information Status : No
Associated Fluid Cache State : Not Applicable
Device Name : /dev/sda # 在系统里边的设备名称
Bus Protocol : SAS
Media : HDD
Read Policy : Read Ahead
Write Policy : Write Back
Cache Policy : Not Applicable
Stripe Element Size : 64 KB # 缓存的条带
Disk Cache Policy : Unchanged
ID : 1
Status : Ok
Name : Virtual Disk1
State : Ready
Hot Spare Policy violated : Not Assigned
Encrypted : No
Layout : RAID-5
Size : 6,142.13 GB (6595056500736 bytes)
T10 Protection Information Status : No
Associated Fluid Cache State : Not Applicable
Device Name : /dev/sdb
Bus Protocol : SAS
Media : HDD
Read Policy : Read Ahead
Write Policy : Write Back
Cache Policy : Not Applicable
Stripe Element Size : 64 KB
Disk Cache Policy : Unchanged
- 阵列卡信息
这里只有一块阵列卡
./omreport storage controller
Controller PERC H730 Mini(Embedded)
Controller
ID : 0
Status : Ok
Name : PERC H730 Mini
Slot ID : Embedded
State : Ready
Firmware Version : 25.5.3.0005
Minimum Required Firmware Version : Not Applicable
Driver Version : 07.701.17.00-rh1
Minimum Required Driver Version : Not Applicable
Storport Driver Version : Not Applicable
Minimum Required Storport Driver Version : Not Applicable
Number of Connectors : 1
Rebuild Rate : 30%
BGI Rate : 30%
Check Consistency Rate : 30%
Reconstruct Rate : 30%
Alarm State : Not Applicable
Cluster Mode : Not Applicable
SCSI Initiator ID : Not Applicable
Cache Memory Size : 1024 MB
Patrol Read Mode : Auto
Patrol Read State : Stopped
Patrol Read Rate : 30%
Patrol Read Iterations : 82
Abort Check Consistency on Error : Disabled
Allow Revertible Hot Spare and Replace Member : Enabled
Load Balance : Not Applicable
Auto Replace Member on Predictive Failure : Disabled
Redundant Path view : Not Applicable
CacheCade Capable : Not Applicable
Persistent Hot Spare : Disabled
Encryption Capable : Yes
Encryption Key Present : No
Encryption Mode : None
Preserved Cache : Not Applicable
Spin Down Unconfigured Drives : Disabled
Spin Down Hot Spares : Disabled
Spin Down Configured Drives : Disabled
Automatic Disk Power Saving (Idle C) : Disabled
Start Time (HH:MM) : Not Applicable
Time Interval for Spin Up (in Hours) : Not Applicable
T10 Protection Information Capable : Yes
Current Controller Mode : RAID
- 阵列卡电源状态
./omreport storage battery
List of Batteries in the System
Controller PERC H730 Mini (Slot Embedded)
ID : 0
Status : Ok
Name : Battery
State : Ready
Recharge Count : Not Applicable
Max Recharge Count : Not Applicable
Learn State : Not Applicable
Next Learn Time : Not Applicable
Maximum Learn Delay : Not Applicable