模块有三个ADC

 

 

 

官方例程打印

 

 

adc0 2553 32             采集的模组的温度为 32摄氏度

adc1 2213 3296         采集的供电电压为 3296mV

adc2 4095 1128         采集的外面的ADC0引脚的电压为 1128mV

 

 

 

 

使用ADC0采集NTC温度传感器B3950(10K)

1.电路图上使用 431电路产生一个 2.5V的基准电压.

R7是功率电阻,R10是高精度电阻,建议1%及其以上

 

 

2.安装传感器

 

 

 

 

3.把以下程序拷贝到main.lua并下载到开发板

-- LuaTools需要PROJECT和VERSION这两个信息
PROJECT = "adcdemo"
VERSION = "1.0.0"

-- 一定要添加sys.lua !!!!
local sys = require "sys"



adc.open(2) -- 模块上的ADC0脚, 0-1.8v,不要超过范围使用!!!

--建表
Temp_Tab_10K=                                                            
{
    95.3370,92.6559,90.0580,87.5406,85.1009,82.7364,80.4445,78.2227,76.0689,73.9806,    ---20~-15.5
    71.9558,69.9923,68.0881,66.2412,64.4499,62.7122,61.0264,59.3908,57.8038,56.2639,    ---15~-10.5
    54.7694,53.3189,51.9111,50.5445,49.2178,47.9298,46.6792,45.4649,44.2856,43.1403,    ---10~-5.5
    42.0279,40.9447,39.8978,38.8780,37.8873,36.9246,35.9892,35.0801,34.1965,33.3378,    ---5~-0.5
    32.5030,31.6915,30.9026,30.1355,29.3896,28.6644,27.9590,27.2730,26.6058,25.9567,    --0~4.5
    25.3254,24.7111,24.1135,23.5320,22.9661,22.4154,21.8795,21.3579,20.8502,20.3559,    --5~9.5
    19.8747,19.4063,18.9502,18.5060,18.0735,17.6523,17.2421,16.8426,16.4534,16.0743,    --10~14.5
    15.7049,15.3450,14.9944,14.6528,14.3198,13.9954,13.6792,13.3710,13.0705,12.7777,    --15~19.5
    12.4922,12.2138,11.9425,11.6778,11.4198,11.1681,10.9227,10.6834,10.4499,10.2222,    --20~24.5
    10.000,9.7833,9.5718,9.3655,9.1642,8.9677,8.7760,8.5889,8.4063,8.2281,    --25~29.5
    8.0541,7.8842,7.7184,7.5565,7.3985,7.2442,7.0935,6.9463,6.8026,6.6622,    --30~34.5
    6.5251,6.3912,6.2604,6.1326,6.0077,5.8858,5.7666,5.6501,5.5363,5.4251,    --35~39.5
    5.3164,5.2102,5.1064,5.0049,4.9057,4.8088,4.7140,4.6213,4.5307,4.4421,    --40~44.5
    4.3554,4.2707,4.1878,4.1068,4.0275,3.9500,3.8742,3.8000,3.7275,3.6565,    --45~49.5
    3.5870,3.5190,3.4525,3.3875,3.3238,3.2615,3.2005,3.1408,3.0824,3.0252,    --50~54.5
    2.9692,2.9144,2.8608,2.8082,2.7568,2.7065,2.6572,2.6089,2.5616,2.5153,    --55~59.4
    2.4700,2.4255,2.3820,2.3394,2.2977,2.2568,2.2167,2.1775,2.1390,2.1013,    --60~64.5
    2.0644,2.0282,1.9928,1.9580,1.9240,1.8906,1.8579,1.8258,1.7944,1.7636,    --65~69.5
    1.7334,1.7037,1.6747,1.6462,1.6183,1.5910,1.5641,1.5378,1.5120,1.4867,    --70~74.5
    1.4619,1.4375,1.4136,1.3902,1.3672,1.3447,1.3225,1.3008,1.2795,1.2586,    --75~79.5
    1.2381,1.2180,1.1983,1.1789,1.1599,1.1412,1.1229,1.1050,1.0873,1.0700,    --80~84.5
    1.0530,1.0363,1.0199,1.0038,0.9880,0.9725,0.9573,0.9424,0.9277,0.9133,    --85~89.5
    0.8991,0.8852,0.8715,0.8581,0.8450,0.8320,0.8193,0.8068,0.7945,0.7825,    --90~94.5
    0.7707,0.7590,0.7476,0.7364,0.7253,0.7145,0.7038,0.6933,0.6831,0.6729,    --95~99.5
    0.6630    --100
}

--获取采集的温度
local function Get_Temp()
    local Temperature = 0;
    local adcval,voltval = adc.read(2)
    local value = voltval/1000;
    local Resistance = 82*(value/(2.5-value))
    for k, v in pairs(Temp_Tab_10K) do 
        if Resistance> v then
            Temperature = (((k-1)-40)/2) 
            break;
        end     
    end 
    return  Temperature;
end 


sys.taskInit(function()
    while 1 do
        log.debug("Temperature=", Get_Temp())  
        sys.wait(500);
    end
end)


-- 用户代码已结束---------------------------------------------
-- 结尾总是这一句
sys.run()
-- sys.run()之后后面不要加任何语句!!!!!

 

 