4.GlusterFS 常见故障处理

  一般硬盘也要备用几块,因为随着发展,可能这些型号的硬盘不好买到了,一般的事故不会在开始一两年出,在硬件老化的时候出故障的频率高。

4.1 硬盘故障

如果底层做了 RAID 配置,有硬件故障,直接更换硬盘,会自动同步数据。
如果没有做 RAID,处理方法如下:

正常节点上执行 gluster volume status,记录故障节点 uuid
执行:getfattr -d -m ‘.*’ /brick 记录 trusted.gluster.volume-id 及 trusted.gfid

以下为故障模拟及修复过程:

在 VMware Workstation 上移除 mystorage1 主机的第三块硬盘(对应 sdc /storage/brick2),相当于硬盘故障

# 系统提示如下:
Message from syslogd@linux-node01 at Jul 30 08:41:46 ...
 storage-brick2[5893]: [2016-07-30 00:41:46.729896] M [MSGID: 113075] [posix-helpers.c:1844:posix_health_check_thread_proc] 0-gv2-posix: health-check failed, going down

Message from syslogd@linux-node01 at Jul 30 08:42:16 ...
 storage-brick2[5893]: [2016-07-30 00:42:16.730518] M [MSGID: 113075] [posix-helpers.c:1850:posix_health_check_thread_proc] 0-gv2-posix: still alive! -> SIGTERM

 # 查看卷状态,mystorage1:/storage/brick2 不在线了,不过这是分布式复制卷,还可以访问另外 brick 上的数据
[root@mystorage1 ~]# gluster volume status gv2 
Status of volume: gv2
Gluster process                             TCP Port  RDMA Port  Online  Pid
------------------------------------------------------------------------------
Brick mystorage1:/storage/brick2            N/A       N/A        N       N/A  

在 VMware Workstation 上新增 mystorage1 一块硬盘,相当于更换了新硬盘,下面先格式挂载新硬盘:

 
# mkfs.xfs -f /dev/sdc
# mkdir -p /storage/brick2
# mount -a
# df -h

# 新硬盘挂载后目录为空
[root@mystorage1 ~]# ll /storage/brick2
total 0

开始手动配置新增硬盘的 gluster 参数

# 在 mystorage2 是获取 glusterfs 相关参数:
[root@mystorage2 tmp]# getfattr -d -m '.*'  /storage/brick2
getfattr: Removing leading '/' from absolute path names
# file: storage/brick2
trusted.gfid=0sAAAAAAAAAAAAAAAAAAAAAQ==
trusted.glusterfs.dht=0sAAAAAQAAAAAAAAAAf////g==
trusted.glusterfs.dht.commithash="3168624641"
trusted.glusterfs.quota.dirty=0sMAA=
trusted.glusterfs.quota.size.1=0sAAAAAATiAAAAAAAAAAAAAwAAAAAAAAAE
trusted.glusterfs.volume-id=0sEZKGliY6THqhVVEVrykiHw==

# 在 mystorage1 上执行配置 glusterfs 参数和上述一样

setfattr -n trusted.gfid -v 0sAAAAAAAAAAAAAAAAAAAAAQ== /storage/brick2
setfattr -n trusted.glusterfs.dht -v 0sAAAAAQAAAAAAAAAAf////g== /storage/brick2
setfattr -n trusted.glusterfs.dht.commithash -v "3168624641" /storage/brick2
setfattr -n trusted.glusterfs.quota.dirty -v 0sMAA= /storage/brick2
setfattr -n trusted.glusterfs.quota.size.1 -v 0sAAAAAATiAAAAAAAAAAAAAwAAAAAAAAAE /storage/brick2
setfattr -n trusted.glusterfs.volume-id -v 0sEZKGliY6THqhVVEVrykiHw== /storage/brick2

[root@mystorage1 ~]# /etc/init.d/glusterd restart
Starting glusterd:                                         [  OK  ]


[root@mystorage1 ~]# gluster volume heal gv2 info
Brick mystorage1:/storage/brick2
Status: Connected
Number of entries: 0

Brick mystorage2:/storage/brick2
/data 
Status: Connected
Number of entries: 1        # 显示一个条目在修复,自动修复完成后会为 0

Brick mystorage3:/storage/brick1
Status: Connected
Number of entries: 0

Brick mystorage4:/storage/brick1
Status: Connected
Number of entries: 0

# 自动修复同步完成后,查看新硬盘的数据同步过来了
[root@mystorage1 ~]# ll /storage/brick2
total 40012
-rw-r--r-- 2 root root 20480000 Jul 30 02:41 20M.file
-rw-r--r-- 2 root root 20480000 Jul 30 03:13 20M.file1
drwxr-xr-x 2 root root       21 Jul 30 09:14 data

4.2 一台主机故障

一台节点故障的情况包含以下情况:

  • 物理故障
  • 同时有多块硬盘故障,造成数据丢失
  • 系统损坏不可修复

解决方法:

找一台完全一样的机器,至少要保证硬盘数量和大小一致,安装系统,配置和故障机同样的 IP,安装 gluster 软件,
保证配置一样,在其他健康节点上执行命令 gluster peer status,查看故障服务器的 uuid

[root@mystorage2 ~]# gluster peer status
Number of Peers: 3

Hostname: mystorage3
Uuid: 36e4c45c-466f-47b0-b829-dcd4a69ca2e7
State: Peer in Cluster (Connected)

Hostname: mystorage4
Uuid: c607f6c2-bdcb-4768-bc82-4bc2243b1b7a
State: Peer in Cluster (Connected)

Hostname: mystorage1
Uuid: 6e6a84af-ac7a-44eb-85c9-50f1f46acef1
State: Peer in Cluster (Disconnected)

修改新加机器的 /var/lib/glusterd/glusterd.info 和 故障机器一样

[root@mystorage1 ~]# cat /var/lib/glusterd/glusterd.info
UUID=6e6a84af-ac7a-44eb-85c9-50f1f46acef1
operating-version=30712

在信任存储池中任意节点执行

# gluster volume heal gv2 full

就会自动开始同步,但在同步的时候会影响整个系统的性能。

可以查看状态

# gluster volume heal gv2 info

 

posted @ 2017-03-22 21:53  谢小花❀  阅读(4366)  评论(0编辑  收藏  举报