H3C-STP -TC
Core Switch Error Reporting:
Instance 0's port Bridge-Aggregation72 was notified a topology change.
Reasons:
一般是二层交换机上的端口一直up/down导致网络中发生了stp拓扑变化,端口向上通报网络拓扑发生变化
resolution:
1.全局开启BPDU保护:stp bpdu-protection
2.不参与STP计算的端口开启边缘端口:stp edged-port
若还有大量BPDU TC,可能是stp模式不一致导致的,尤其是不同厂商间的交换机的默认stp模式不同,不兼容导致的
254:
%Nov 17 08:43:20:177 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
%Nov 17 08:43:22:206 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
%Nov 17 08:58:03:723 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
%Nov 17 09:12:53:781 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
%Nov 17 09:17:35:791 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
%Nov 17 09:29:59:856 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
%Nov 17 09:32:43:840 2023 MIS-D3F-MDF-S10506X-01&02 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation72 was notified a topology change.
[MIS-D3F-MDF-S10506X-01&02]dis link-aggregation verbose Bridge-Aggregation 72
Loadsharing Type: Shar -- Loadsharing, NonS -- Non-Loadsharing
Port Status: S -- Selected, U -- Unselected, I -- Individual
Port: A -- Auto port, M -- Management port, R -- Reference port
Flags: A -- LACP_Activity, B -- LACP_Timeout, C -- Aggregation,
D -- Synchronization, E -- Collecting, F -- Distributing,
G -- Defaulted, H -- Expired
Aggregate Interface: Bridge-Aggregation72
Creation Mode: Manual
Aggregation Mode: Dynamic
Loadsharing Type: Shar
Management VLANs: None
System ID: 0x8000, 9c09-71bd-ba00
Local:
Port Status Priority Index Oper-Key Flag
GE1/1/0/6 S 32768 80 70 {ACDEF}
GE2/1/0/6 S 32768 116 70 {ACDEF}
Remote:
Actor Priority Index Oper-Key SystemID Flag
GE1/1/0/6 32768 2 1 0x8000, 58c7-ac64-d77c {ACDEF}
GE2/1/0/6(R) 32768 1 1 0x8000, 58c7-ac64-d77c {ACDEF}
[MIS-D3F-MDF-S10506X-01&02]dis arp | include BAGG72
10.20.1.65 58c7-ac64-d786 4000 BAGG72 713 D
10.20.1.76 58c7-ac63-bfc6 4000 BAGG72 637 D
10.20.1.173 58c7-ac64-dc06 4000 BAGG72 637 D
10.20.1.203 5cdd-7083-3e64 4000 BAGG72 637 D
10.20.1.204 5cdd-7083-3a8a 4000 BAGG72 713 D
10.20.1.205 5cdd-70be-bf4c 4000 BAGG72 637 D
10.20.1.206 58c7-ac64-e026 4000 BAGG72 637 D
65:
%Nov 17 08:35:39:723 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:35:39:851 2023 MIS-D2F-ES1-S5130S-09 DRVPLAT/4/SOFTCAR DROP:
PktType=ARP, SrcMAC=a069-d99b-b582, Dropped from interface=Ten-GigabitEthernet1/0/51 at Stage=17, StageCnt=22633, TotalCnt=2515071, MaxRateInterface=Ten-GigabitEthernet1/0/52.
%Nov 17 08:43:20:174 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:43:22:203 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:58:03:718 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:12:53:774 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:17:35:787 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:29:59:810 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:32:43:835 2023 MIS-D2F-ES1-S5130S-09 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
76:
%Nov 17 08:35:39:709 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:35:39:820 2023 MIS-D2F-ES1-S5130S-10 DRVPLAT/4/SOFTCAR DROP:
PktType=ARP, SrcMAC=58c7-ac64-dd86, Dropped from interface=Ten-GigabitEthernet1/0/51 at Stage=17, StageCnt=26156, TotalCnt=2943903, MaxRateInterface=Ten-GigabitEthernet1/0/52.
%Nov 17 08:43:20:160 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:43:22:170 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:58:03:689 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:10:15:855 2023 MIS-D2F-ES1-S5130S-10 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/37 changed to down.
%Nov 17 09:10:15:862 2023 MIS-D2F-ES1-S5130S-10 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/37 changed to down.
%Nov 17 09:10:18:898 2023 MIS-D2F-ES1-S5130S-10 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/37 changed to up.
%Nov 17 09:10:18:907 2023 MIS-D2F-ES1-S5130S-10 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/37 changed to up.
%Nov 17 09:12:53:771 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:12:54:257 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:17:35:768 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:17:36:331 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:25:50:748 2023 MIS-D2F-ES1-S5130S-10 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/31 changed to down.
%Nov 17 09:25:50:755 2023 MIS-D2F-ES1-S5130S-10 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/31 changed to down.
%Nov 17 09:25:53:710 2023 MIS-D2F-ES1-S5130S-10 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/31 changed to up.
%Nov 17 09:25:53:716 2023 MIS-D2F-ES1-S5130S-10 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/31 changed to up.
%Nov 17 09:29:59:777 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:32:43:817 2023 MIS-D2F-ES1-S5130S-10 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
173:
%Nov 17 08:35:39:803 2023 MIS-D2F-ES1-S5130S-12 DRVPLAT/4/SOFTCAR DROP:
PktType=ARP, SrcMAC=58c7-ac64-dd86, Dropped from interface=Ten-GigabitEthernet1/0/51 at Stage=17, StageCnt=26836, TotalCnt=2936467, MaxRateInterface=Ten-GigabitEthernet1/0/52.
%Nov 17 08:35:39:995 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:43:20:145 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:43:21:989 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:43:22:168 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:58:03:687 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:04:46:680 2023 MIS-D2F-ES1-S5130S-12 LLDP/6/LLDP_DELETE_NEIGHBOR: Nearest bridge agent neighbor deleted on port GigabitEthernet1/0/33 (IfIndex 33), neighbor's chassis ID is 7486-e206-97d9, port ID is 7486-e206-97d9.
%Nov 17 09:12:53:756 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:12:54:254 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:17:35:756 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:17:36:325 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:29:59:774 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:30:00:082 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:32:43:810 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:32:44:112 2023 MIS-D2F-ES1-S5130S-12 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
203:
%Nov 17 08:39:50:393 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is DOWN.
%Nov 17 08:40:23:372 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:40:23:963 2023 MIS-NewCanteen-F1-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-70be-bf4b, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:40:25:392 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is DOWN.
%Nov 17 08:40:58:423 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:40:58:966 2023 MIS-NewCanteen-F1-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-70be-bf4b, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:41:00:797 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is DOWN.
%Nov 17 08:41:33:413 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:41:33:978 2023 MIS-NewCanteen-F1-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-70be-bf4b, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:41:35:395 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is DOWN.
%Nov 17 08:42:08:304 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:42:08:963 2023 MIS-NewCanteen-F1-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-70be-bf4b, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:42:10:393 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is DOWN.
%Nov 17 08:42:43:265 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:42:43:962 2023 MIS-NewCanteen-F1-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-70be-bf4b, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:42:44:812 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/25 link status is UP.
%Nov 17 08:42:44:826 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/25 has been set to forwarding state.
%Nov 17 08:42:45:498 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is DOWN.
%Nov 17 08:43:18:498 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:43:18:961 2023 MIS-NewCanteen-F1-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-70be-bf4b, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:43:20:154 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/48 has been set to forwarding state.
%Nov 17 08:43:20:155 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/48 detected a topology change.
%Nov 17 08:43:22:004 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/48 was notified of a topology change.
%Nov 17 08:51:02:252 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/25 link status is DOWN.
%Nov 17 08:51:04:515 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/25 link status is UP.
%Nov 17 08:51:04:530 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/25 has been set to forwarding state.
%Nov 17 08:58:03:702 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/47 was notified of a topology change.
%Nov 17 09:06:10:852 2023 MIS-NewCanteen-F1-S5120-01 SHELL/6/SHELL_CMD: -Task=vt0-IPAddr=10.20.46.128-User=admin; Command is dis stp brief
%Nov 17 09:12:53:770 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/47 was notified of a topology change.
%Nov 17 09:14:31:012 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/25 link status is DOWN.
%Nov 17 09:17:35:769 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/47 was notified of a topology change.
%Nov 17 09:19:30:899 2023 MIS-NewCanteen-F1-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/25 link status is UP.
%Nov 17 09:19:30:913 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/25 has been set to forwarding state.
%Nov 17 09:29:59:807 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/47 was notified of a topology change.
%Nov 17 09:32:43:798 2023 MIS-NewCanteen-F1-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/47 was notified of a topology change.
204:
%Nov 17 08:43:20:181 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/48 was notified of a topology change.
%Nov 17 08:43:22:184 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/48 was notified of a topology change.
%Nov 17 08:56:39:800 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/1 link status is DOWN.
%Nov 17 08:57:32:900 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/1 link status is UP.
%Nov 17 08:58:02:711 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/1 has been set to forwarding state.
%Nov 17 08:58:02:711 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/1 detected a topology change.
%Nov 17 09:12:22:866 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/7 link status is UP.
%Nov 17 09:12:52:805 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/7 has been set to forwarding state.
%Nov 17 09:12:52:805 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/7 detected a topology change.
%Nov 17 09:17:05:199 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/11 link status is UP.
%Nov 17 09:17:34:801 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/11 has been set to forwarding state.
%Nov 17 09:17:34:802 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/11 detected a topology change.
%Nov 17 09:24:54:831 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/2 link status is DOWN.
%Nov 17 09:24:57:139 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/2 link status is UP.
%Nov 17 09:24:58:308 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/2 link status is DOWN.
%Nov 17 09:29:30:348 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/8 link status is UP.
%Nov 17 09:29:59:852 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/8 has been set to forwarding state.
%Nov 17 09:29:59:853 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/8 detected a topology change.
%Nov 17 09:32:14:517 2023 MIS-NEWCanteen-F2-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/6 link status is UP.
%Nov 17 09:32:43:863 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/6 has been set to forwarding state.
%Nov 17 09:32:43:864 2023 MIS-NEWCanteen-F2-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/6 detected a topology change.
205:
%Nov 17 08:43:19:308 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/48 link status is UP.
%Nov 17 08:43:19:437 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: Vlan-interface1 link status is UP.
%Nov 17 08:43:19:597 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/5/LINEPROTO_UPDOWN: Line protocol on the interface Vlan-interface1 is UP.
%Nov 17 08:43:19:747 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: Vlan-interface4000 link status is UP.
%Nov 17 08:43:19:917 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/5/LINEPROTO_UPDOWN: Line protocol on the interface Vlan-interface4000 is UP.
%Nov 17 08:43:20:257 2023 MIS-NEWCanteen-F3-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/48 (IfIndex 9437231), Chassis ID is 5cdd-7083-3e63, Port ID is GigabitEthernet1/0/48.
%Nov 17 08:43:20:437 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_DISCARDING: Instance 0's port GigabitEthernet1/0/3 has been set to discarding state.
%Nov 17 08:43:20:617 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_DISCARDING: Instance 0's port GigabitEthernet1/0/5 has been set to discarding state.
%Nov 17 08:43:20:807 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_DISCARDING: Instance 0's port GigabitEthernet1/0/11 has been set to discarding state.
%Nov 17 08:43:20:997 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/48 has been set to forwarding state.
%Nov 17 08:43:21:177 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/48 detected a topology change.
%Nov 17 08:43:21:367 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/48 was notified of a topology change.
%Nov 17 08:43:21:547 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/5 has been set to forwarding state.
%Nov 17 08:43:22:937 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_NOTIFIED_TC: Instance 0's port GigabitEthernet1/0/48 was notified of a topology change.
%Nov 17 08:43:22:938 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is undo stp
%Nov 17 08:43:30:039 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is undo stp edged-port
%Nov 17 08:43:32:806 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is qu
%Nov 17 08:43:40:751 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is ping 10.20.1.254
%Nov 17 08:43:42:388 2023 MIS-NEWCanteen-F3-S5120-01 PING/6/PING_LOG: 10.20.1.254 ping statistics: 5 packet(s) transmitted; 5 packet(s) received; packet loss: 0.00%; round-trip min/avg/max = 3/3/4 ms.
%Nov 17 08:43:50:637 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/3 has been set to forwarding state.
%Nov 17 08:43:50:837 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/11 has been set to forwarding state.
%Nov 17 08:44:04:157 2023 MIS-NEWCanteen-F3-S5120-01 NTP/5/NTP_CHANGE_LEAP: System Leap Indicator changed from 3 to 0 after clock update.
%Nov 17 08:44:04:327 2023 MIS-NEWCanteen-F3-S5120-01 NTP/5/NTP_CHANGE_STRATUM: System stratum changed from 16 to 2 after clock update.
%Nov 17 08:44:20:569 2023 MIS-NEWCanteen-F3-S5120-01 CFGMAN/5/CFGMAN_CFGCHANGED: -EventIndex=13-CommandSource=2-ConfigSource=4-ConfigDestination=2; Configuration is changed.
%Nov 17 08:44:40:372 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis cu
%Nov 17 08:45:53:641 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis cu
%Nov 17 08:46:47:095 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is interface GigabitEthernet 1/0/1
%Nov 17 08:47:00:791 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is port access vlan 35
%Nov 17 08:47:13:615 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is stp edged-port enable
%Nov 17 08:47:31:270 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is qu
%Nov 17 08:47:46:430 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis cu
%Nov 17 08:48:07:735 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/3 link status is DOWN.
%Nov 17 08:48:23:745 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/1 link status is UP.
%Nov 17 08:48:23:956 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/1 has been set to forwarding state.
%Nov 17 08:50:02:700 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis cu
%Nov 17 08:51:54:098 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis logbuffer
%Nov 17 08:54:20:574 2023 MIS-NEWCanteen-F3-S5120-01 CFGMAN/5/CFGMAN_CFGCHANGED: -EventIndex=14-CommandSource=2-ConfigSource=4-ConfigDestination=2; Configuration is changed.
%Nov 17 08:56:31:622 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis logbuffer
%Nov 17 08:58:46:220 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis stp brief
%Nov 17 09:00:40:782 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=au0-IPAddr=**-User=admin; Command is dis cu
%Nov 17 09:01:47:729 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/31 link status is UP.
%Nov 17 09:01:48:589 2023 MIS-NEWCanteen-F3-S5120-01 LLDP/6/LLDP_CREATE_NEIGHBOUR: New neighbor created on Port GigabitEthernet1/0/31 (IfIndex 9437214), Chassis ID is a029-191a-9815, Port ID is a029-191a-9815.
%Nov 17 09:02:17:480 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/31 has been set to forwarding state.
%Nov 17 09:02:17:689 2023 MIS-NEWCanteen-F3-S5120-01 MSTP/6/MSTP_DETECTED_TC: Instance 0's port GigabitEthernet1/0/31 detected a topology change.
%Nov 17 09:06:36:998 2023 MIS-NEWCanteen-F3-S5120-01 SSH/6/SSH_LOGIN: STEL user admin (IP: 10.20.46.128) logged in successfully.
%Nov 17 09:06:37:457 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/5/SHELL_LOGIN: admin logged in from 10.20.46.128.
%Nov 17 09:06:44:428 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=vt0-IPAddr=10.20.46.128-User=admin; Command is dis stp brief
%Nov 17 09:06:56:453 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=vt0-IPAddr=10.20.46.128-User=admin; Command is dis logbuffer
%Nov 17 09:08:44:216 2023 MIS-NEWCanteen-F3-S5120-01 IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/31 link status is DOWN.
%Nov 17 09:11:53:995 2023 MIS-NEWCanteen-F3-S5120-01 CFGMAN/5/CFGMAN_EXIT: Exit from configuration mode.
%Nov 17 09:11:54:577 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/5/SHELL_LOGOUT: admin logged out from aux0.
%Nov 17 09:16:59:991 2023 MIS-NEWCanteen-F3-S5120-01 CFGMAN/5/CFGMAN_EXIT: Exit from configuration mode.
%Nov 17 09:16:59:992 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/5/SHELL_LOGOUT: admin logged out from 10.20.46.128.
%Nov 17 09:16:59:992 2023 MIS-NEWCanteen-F3-S5120-01 SSH/6/SSH_CONNECTION_CLOSE: STEL user admin (IP: 10.20.46.128) logged out because the SSH client closed the connection.
%Nov 17 09:21:49:211 2023 MIS-NEWCanteen-F3-S5120-01 SC/6/SC_AAA_LAUNCH: -AAAType=AUTHEN-AAAScheme= local-Service=login-UserName=admin@system; AAA launched.
%Nov 17 09:21:49:211 2023 MIS-NEWCanteen-F3-S5120-01 SC/6/SC_AAA_SUCCESS: -AAAType=AUTHEN-AAAScheme= local-Service=login-UserName=admin@system; AAA is successful.
%Nov 17 09:21:49:212 2023 MIS-NEWCanteen-F3-S5120-01 SC/6/SC_AAA_LAUNCH: -AAAType=AUTHOR-AAAScheme= local-Service=login-UserName=admin@system; AAA launched.
%Nov 17 09:21:49:213 2023 MIS-NEWCanteen-F3-S5120-01 SC/6/SC_AAA_SUCCESS: -AAAType=AUTHOR-AAAScheme= local-Service=login-UserName=admin@system; AAA is successful.
%Nov 17 09:21:49:214 2023 MIS-NEWCanteen-F3-S5120-01 SC/6/SC_AAA_LAUNCH: -AAAType=ACCOUNT-AAAScheme= local-Service=login-UserName=admin@system; AAA launched.
%Nov 17 09:21:49:215 2023 MIS-NEWCanteen-F3-S5120-01 SC/6/SC_AAA_SUCCESS: -AAAType=ACCOUNT-AAAScheme= local-Service=login-UserName=admin@system; AAA is successful.
%Nov 17 09:21:49:246 2023 MIS-NEWCanteen-F3-S5120-01 SSH/6/SSH_LOGIN: STEL user admin (IP: 10.20.46.128) logged in successfully.
%Nov 17 09:21:49:343 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/5/SHELL_LOGIN: admin logged in from 10.20.46.128.
%Nov 17 09:22:31:747 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=vt0-IPAddr=10.20.46.128-User=admin; Command is dis logbuffer
%Nov 17 09:27:14:110 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=vt0-IPAddr=10.20.46.128-User=admin; Command is sys
%Nov 17 09:33:37:631 2023 MIS-NEWCanteen-F3-S5120-01 SHELL/6/SHELL_CMD: -Task=vt0-IPAddr=10.20.46.128-User=admin; Command is dis stp tc
206:
%Nov 17 08:43:20:163 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:43:22:185 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 08:58:03:710 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:10:32:075 2023 MIS-D2F-ES1-S5130S-11 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/35 changed to down.
%Nov 17 09:10:32:082 2023 MIS-D2F-ES1-S5130S-11 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/35 changed to down.
%Nov 17 09:10:36:060 2023 MIS-D2F-ES1-S5130S-11 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/35 changed to up.
%Nov 17 09:10:36:062 2023 MIS-D2F-ES1-S5130S-11 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/35 changed to up.
%Nov 17 09:10:36:132 2023 MIS-D2F-ES1-S5130S-11 LLDP/6/LLDP_CREATE_NEIGHBOR: Nearest bridge agent neighbor created on port GigabitEthernet1/0/35 (IfIndex 35), neighbor's chassis ID is 10e7-c624-8344, port ID is 10e7-c624-8344.
%Nov 17 09:12:53:772 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:17:35:772 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:29:59:798 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:30:22:842 2023 MIS-D2F-ES1-S5130S-11 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/35 changed to down.
%Nov 17 09:30:22:843 2023 MIS-D2F-ES1-S5130S-11 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/35 changed to down.
%Nov 17 09:30:26:413 2023 MIS-D2F-ES1-S5130S-11 IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/35 changed to up.
%Nov 17 09:30:26:422 2023 MIS-D2F-ES1-S5130S-11 IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/35 changed to up.
%Nov 17 09:30:39:927 2023 MIS-D2F-ES1-S5130S-11 LLDP/6/LLDP_CREATE_NEIGHBOR: Nearest bridge agent neighbor created on port GigabitEthernet1/0/35 (IfIndex 35), neighbor's chassis ID is 10e7-c624-8344, port ID is 10e7-c624-8344.
%Nov 17 09:32:43:821 2023 MIS-D2F-ES1-S5130S-11 STP/6/STP_NOTIFIED_TC: Instance 0's port Bridge-Aggregation2 was notified a topology change.
%Nov 17 09:33:13:854 2023 MIS-D2F-ES1-S5130S-11 LLDP/6/LLDP_DELETE_NEIGHBOR: Nearest bridge agent neighbor deleted on port GigabitEthernet1/0/35 (IfIndex 35), neighbor's chassis ID is 10e7-c624-8344, port ID is 10e7-c624-8344.
%Nov 17 09:33:13:858 2023 MIS-D2F-ES1-S5130S-11 LLDP/6/LLDP_CREATE_NEIGHBOR: Nearest bridge agent neighbor created on port GigabitEthernet1/0/35 (IfIndex 35), neighbor's chassis ID is 10e7-c624-8344, port ID is 10e7-c624-8344.
Total Used Free Shared Buffers Cached FreeRatio
收到了TC报文,说明网络有拓扑变化,看下接终端的端口是否配置边缘端口,是否有端口频繁UP/DOWN
TC报文日志提醒,说明聚合50 70口对端设备有端口UP DOWN
这是STP TC报文提示的拓扑改变,以下是排查要点,请参考:
1、检查端口是否频繁UP DOWN
2、检查物理链路是否有问题。
3、检查主根是否稳定。
4、登录到对端设备看是否也有上述情况
如果经常出现这类的日志,且很频繁,STP的TC报文过多,可能会出现STP TC震荡从而影响到业务,以下是排查要点,请参考:
1、终端接入的端口可开启STP边缘端口,以下是参考命令:
int gi 1/0/1
stp edge-port enable
quit
2、检查设备之间、设备到终端的物理链路是否有问题。
3、检查STP根桥是否稳定,可在根桥的下行端口开启STP根保护。
4、使用dis stp tc看下哪些端口在TC报文收、发统计在增长,增长频繁的,根据端口去往对端设备上进一步排查。
5、如果对端设备无法管理到或不是管辖的范围,可考虑开启STP TC保护。
在系统视图下开启bpdu保护,如果不开启此功能,边缘端口收到bpdu报文(比如收到bpdu攻击的时候)会转变为非边缘端口,开启bpdu保护后,再收到bpdu报文,stp将关闭该端口,系统视图下:
stp bpdu-protection
交换机开启了stp环路保护协议,当参与stp计算的端口发生up/down时,就会TC报文,通知相邻网桥拓扑发生变化,如果你这个端口连接的是服务器或者是终端,可以再端口下关闭stp或者设置成边缘端口,就不会再有这个提示了
int g1/0/1
undo stp en 端口视图下关闭stp
int g1/0/1
stp edged-port 开启边缘端口
CVE-2023-48233
Vim v9.0.2108之前版本存在输入验证错误漏洞,该漏洞源于如果s命令后的计数大于长整型变量的计数,程序可能会中止。
http://KS1DSCCM1.ivo.com.cn:80
- Start Windows PowerShell as an administrator.
- Run the following Add-WindowsCapability cmdlets to install the SNMP and WMI SNMP Provider features.
Reference:
2. Switch Alarm Logs
dis logbuffer
dis logbuffer re
logfile save
Information Center display and maintenance
reset logbuffer clears the logbuffer statistics.
| 操作 | 命令 |
|---|---|
| 显示诊断日志文件的配置 | display diagnostic-logfile summary |
| 显示各个输出方向的信息 | display info-center |
| 显示用户创建的日志输出规则 | display info-center filter [ filtername ] |
| 显示日志文件缓冲区的内容 | display logfile buffer |
| 显示日志缓冲区的状态和日志缓冲区记录的日志信息 | display logbuffer [ reverse ] [ level severity | size buffersize | slot slot-number ] * [ last-mins mins ] |
| 显示日志缓冲区的概要信息 | display logbuffer summary [ level severity | slot slot-number ] * |
| 显示日志文件的配置 | display logfile summary |
| 显示安全日志文件缓冲区的内容 | display security-logfile buffer |
| 清除日志缓冲区内的信息 | reset logbuffer |
2. 2 配置日志信息保存到日志文件
通过配置日志信息保存到日志文件,用户可以将系统产生的日志信息保存到设备的日志文件中以便随时查看。
日志在保存到日志文件前,先保存在日志文件缓冲区。
系统会按照指定的频率将日志文件缓冲区的内容写入日志文件,频率一般配置为24小时一次,在设备比较空闲的时候(比如清晨)进行保存,用户也可以手工触发保存。成功保存后,保存前的日志文件缓冲区里的内容会被清空。
日志文件有容量限制,当日志文件的大小达到最大值,且日志文件写满保护功能处于关闭状态,系统会自动创建logfile1.log来存储日志。logfile1.log写满后,会被压缩成logfile1.log.gz,再自动创建logfile2.log来存储日志。logfile2.log写满后,会被压缩成logfile2.log.gz,再自动创建logfile3.log来存储日志,以此类推。
当日志文件的个数达到设备支持的最大值时,系统会找出生成时间最早的压缩文件(例如为logfileX.log.gz),并创建一个同名日志文件(logfileX.log)来存储日志,logfileX.log写满后,会被压缩成logfileX.log.gz来替换现有的logfileX.log.gz,以此类推。建议及时备份日志文件和日志压缩文件,以免重要日志被覆盖。
日志文件有容量限制,当日志文件的大小达到最大值,且日志文件写满保护功能处于开启状态,不再覆盖旧日志或旧日志文件,而是停止记录日志。
配置日志信息保存到日志文件
| 操作 | 命令 | 说明 | |
|---|---|---|---|
| 进入系统视图 | system-view | - | |
| 开启信息中心 | info-center enable | 缺省情况下,信息中心处于开启状态 | |
| 开启保存日志文件功能 | info-center logfile enable | 缺省情况下,允许日志信息输出到日志文件 | |
| (可选)开启日志文件写满保护功能 | info-center logfile overwrite-protection [ all-port-powerdown ] | 缺省情况下,日志文件写满保护功能处于关闭状态本命令仅FIPS模式下支持 | |
| (可选)配置单个日志文件最大能占用的存储空间的大小 | info-center logfile size-quota size | 缺省情况下,单个日志文件最大能占用的存储空间为5MB为了保证设备的正常运行,info-center logfile size-quota配置的日志文件的大小最小不能低于1MB,最大不能超过5MB | |
| (可选)配置存储日志文件的目录 | info-center logfile directory dir-name | 缺省情况下,存储日志文件的目录为flash:/logfile配置会在设备重启或主从设备倒换后失效 | |
| 将日志文件缓冲区中的内容保存到日志文件 | 配置自动保存的频率 | info-center logfile frequency freq-sec | 二者选其一缺省情况下,系统自动保存日志文件的频率为86400logfile save命令在任意视图均可执行 |
dis diagnostic-information
收集设备诊断信息,包含配置、路由、接口、硬件、软件、设备日志、运行状态等信息,一般用于设备故障时收集的。
如果要导出诊断信息文件,先使用dir命令查看诊断信息的文件名,通过ftp或TFTP及3CDROM软件进行导出。
路由-->汇聚-->二层-->终端,顺着往下排查,接终端的交换机接口开启边缘端口
STP的TC报文过多,可能会出现STP TC震荡从而影响到业务
1、终端接入的端口可开启STP边缘端口:
int gi 1/0/1
stp edge-port enable
quit
2、检查设备之间、设备到终端的物理链路是否有问题。
3、检查STP根桥是否稳定,可在根桥的下行端口开启STP根保护。
4、使用dis stp tc看下哪些端口在TC报文收、发统计在增长,增长频繁的,根据端口去往对端设备上进一步排查。
5、如果对端设备无法管理到或不是管辖的范围,可考虑开启STP TC保护。
频繁刷新mac地址表,会占用设备资源
会刷新开启了stp设备的mac地址和arp ,会造成2层流量泛洪和转发延迟
建议在交换机末端开启STP功能,及边缘短端口功能,可以减少或防止环路带来的影响。在其端口下:如int g1/0/1后stp edged-port
另外,在系统视图下开启bpdu保护,如果不开启此功能,边缘端口收到bpdu报文(比如收到bpdu攻击的时候)会转变为非边缘端口,开启bpdu保护后,再收到bpdu报文,stp将关闭该端口,系统视图下:
stp bpdu-protection
交换机开启了stp环路保护协议,当参与stp计算的端口发生up/down时,就会TC报文,通知相邻网桥拓扑发生变化,如果你这个端口连接的是服务器或者是终端,可以再端口下关闭stp或者设置成边缘端口,就不会再有这个提示了
int g1/0/1
undo stp en 端口视图下关闭stp
int g1/0/1
stp edged-port 开启边缘端口
References:
dis diagnostic-information收集的是设备诊断信息,包含配置、路由、接口、硬件、软件、设备日志、运行状态等信息,一般用于设备故障时收集的。如果要导出诊断信息文件,先使用dir命令查看诊断信息的文件名,通过TFTP及3CDROM软件进行导出。
路由-->汇聚-->二层-->终端
顺着往下拍查下,接终端的交换机接口开启边缘端口
频繁刷新mac地址表,会占用设备资源
会刷新开启了stp设备的mac地址和arp ,会造成2层流量泛洪和转发延迟
建议在交换机末端开启STP功能,及边缘短端口功能,可以减少或防止环路带来的影响。在其端口下:如int g1/0/1后stp edged-port
另外,在系统视图下开启bpdu保护,如果不开启此功能,边缘端口收到bpdu报文(比如收到bpdu攻击的时候)会转变为非边缘端口,开启bpdu保护后,再收到bpdu报文,stp将关闭该端口,系统视图下:
stp bpdu-protection
交换机开启了stp环路保护协议,当参与stp计算的端口发生up/down时,就会TC报文,通知相邻网桥拓扑发生变化,如果你这个端口连接的是服务器或者是终端,可以再端口下关闭stp或者设置成边缘端口,就不会再有这个提示了
int g1/0/1
undo stp en 端口视图下关闭stp
int g1/0/1
stp edged-port 开启边缘端口
Total Used Free Shared Buffers Cached FreeRatio
收到了TC报文,说明网络有拓扑变化,看下接终端的端口是否配置边缘端口,是否有端口频繁UP/DOWN
TC报文日志提醒,说明聚合50 70口对端设备有端口UP DOWN
这是STP TC报文提示的拓扑改变,以下是排查要点,请参考:
1、检查端口是否频繁UP DOWN
2、检查物理链路是否有问题。
3、检查主根是否稳定。
4、登录到对端设备看是否也有上述情况

浙公网安备 33010602011771号