PG degraded实验


1. 创建一个文件,并把该文件作为对象放到集群中:

[root@node1 ~]# echo "this is test! " >>test.txt
[root@node1 ~]# rados -p testpool ls
[root@node1 ~]# rados -p testpool put test.txt test.txt 
[root@node1 ~]# rados -p testpool ls
test.txt

2. 查看该对象对应的pg号以及osd组:

[root@node1 ~]# ceph osd map testpool test.txt 
osdmap e76 pool 'testpool' (2) object 'test.txt' -> pg 2.8b0b6108 (2.8) -> up ([1,2,0], p1) acting ([1,2,0], p1)

3. 踢除主osd,pg降级,次osd升级为临时主osd:

[root@node2 ~]# systemctl stop ceph-osd@1
[root@node2 ~]# ceph osd map testpool test.txt
osdmap e79 pool 'testpool' (2) object 'test.txt' -> pg 2.8b0b6108 (2.8) -> up ([2,0], p2) acting ([2,0], p2)
[root@node2 ~]# ceph pg dump_stuck |grep ^2.8
2.8     active+undersized+degraded [2,0]          2  [2,0]              2 

4. 此时仍能够访问该对象:

[root@node2 ~]# rados -p testpool get test.txt test.txt
[root@node2 ~]# cat test.txt 
this is test! 

5. 恢复原主osd:

[root@node2 ~]# systemctl start ceph-osd@1
[root@node2 ~]# ceph pg dump_stuck |grep ^2.8
ok
[root@node2 ~]# ceph osd map testpool test.txt
osdmap e82 pool 'testpool' (2) object 'test.txt' -> pg 2.8b0b6108 (2.8) -> up ([1,2,0], p1) acting ([1,2,0], p1)

通过上面的实验可以看出,当承载同一个pg的osd中的主osd out,次osd会临时升任主osd。在一定的时间间隔内,如果主osd up,该osd继续其主osd功能。

参考文献:

大话Ceph--PG那点事儿