SAP FM:在执行FMBB预算工作台检查时系统DUMP的解决办法

启用FM后,经过一系列的配置,在执行FMBB创建预算时,在点击检查按钮后,系统就Dump了。具体Dump内容如下:

 

 

 

 

 

 

 

 

 

 如何解决呢?

看到运行错我的功能代码:GETWA_NOT_ASSIGNED

应用组件:PSM-FM-BCS-BU

找到Note  976463 - FMBB: Runtime errors GETWA_NOT_ASSIGNED

Note内容:

Symptom

You are running the Budgeting Workbench, transaction FMBB.
When you press the check or post button, the runtime error GETWA_NOT_ASSIGNED occurs or the pop-up "Update was ternminated" is sent on the front screen.
The same error could happen for all transactions which are posting BCS budgeting data using the FI-SL generated program.

Other Terms

FMBB, RGZZGLUX, SAPLFMBD_DATABASE_ACCESS, APPEND_FISL_SEL_GENERAL

Reason and Prerequisites

The generic structure GLU1 does not contain the FM field FIKRS
No prerequisites.

Solution

  • If you are under release ECC 500, Check first if the Extension set 'IS-PS' has been activated. To do so, go to the top IMG activity (Menu path SPRO / SAP Customizing Implementation Guide ):
  • Choose the node 'Activation Switch for SAP R/3 Enterprise Extension Set ' and check if application IS-PS is active.
  • If you are under release ECC 600 an higher, check first if the Extension set 'EA-PS' (Public Services) has been activated. To do so, go to the top IMG activity (Menu path SPRO / SAP Customizing Implementation Guide ):
  • Choose the node 'Activate Business Functions' and open the folder/ ENTERPRISE_EXTENSIONS' and check if EA-PS is active.

Execute then the program RGZZGLUX

The XPRA RGZZGLUX generates all FI-SL programs and structures GLU1.
The program needs a maximum of 5 minutes to carry out the generations.Make sure that NOBODY works in the PRODUCTION system during this time since documents posted during this time may be lost. If the system is a test system, this should not be a problem since the data is only test data.
If you want to generate only certain parts of the FI-SL source code, you can also use Transaction GCCG.
Concerning the report RGZZGLUX you may also refer to the SAP Note number 377053.

 
Software Components
 
 Software ComponentFromToAnd Subsequent 
  EA-PS 500 500    
  EA-PS 600 600    
  EA-PS 603 603    
 
 
References
This document refers to
This document is referenced by
Attributes
 
 NameValue 
  Other Components FI-SL-SL-Z Others  
  Other Components XX-PROJ-IMS-UPGR Application Specific Upgrade Tools
 
 
 
本系统我确定已经激活了EA-PS组件,因此SE38执行程序RGZZGLUX问题就得以解决。
 