host主机监控规则
1.先在 Prometheus 主程序目录下创建rules目录,然后在该目录下创建 host.yml文件,内容如下:
内容很多,可以根据实际情况进行调整。
规则参考网址:https://awesome-prometheus-alerts.grep.to/rules
参考网址的规则中,有些地方需要修改,比如:
- alert: HostNetworkReceiveErrors
expr: increase(node_network_receive_errs_total[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host Network Receive Errors (instance {{ $labels.instance }})"
description: "{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}" ```
具体使用的时候需要修改description,最外层的双引号修改成单引号,因为里面的`"%.0f"`已经使用双引号了。修改成:
'{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}'
注意:目录和文件的权限:chown -R prometheus:prometheus rules
```yaml
groups:
- name: Host and hardware
rules:
- alert: HostOutOfMemory
expr: node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10
for: 5m
labels:
severity: warning
annotations:
summary: "Host out of memory (instance {{ $labels.instance }})"
description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostMemoryUnderMemoryPressure
expr: rate(node_vmstat_pgmajfault[1m]) > 1000
for: 5m
labels:
severity: warning
annotations:
summary: "Host memory under memory pressure (instance {{ $labels.instance }})"
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualNetworkThroughputIn
expr: sum by (instance) (irate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual network throughput in (instance {{ $labels.instance }})"
description: "Host network interfaces are probably receiving too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualNetworkThroughputOut
expr: sum by (instance) (irate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual network throughput out (instance {{ $labels.instance }})"
description: "Host network interfaces are probably sending too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskReadRate
expr: sum by (instance) (irate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk read rate (instance {{ $labels.instance }})"
description: "Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskWriteRate
expr: sum by (instance) (irate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk write rate (instance {{ $labels.instance }})"
description: "Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostOutOfDiskSpace
expr: (node_filesystem_avail_bytes{mountpoint="/rootfs"} * 100) / node_filesystem_size_bytes{mountpoint="/rootfs"} < 10
for: 5m
labels:
severity: warning
annotations:
summary: "Host out of disk space (instance {{ $labels.instance }})"
description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostDiskWillFillIn4Hours
expr: predict_linear(node_filesystem_free_bytes{fstype!~"tmpfs"}[1h], 4 * 3600) < 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host disk will fill in 4 hours (instance {{ $labels.instance }})"
description: "Disk will fill in 4 hours at current write rate\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostOutOfInodes
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint ="/rootfs"} * 100 < 10
for: 5m
labels:
severity: warning
annotations:
summary: "Host out of inodes (instance {{ $labels.instance }})"
description: "Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskReadLatency
expr: rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk read latency (instance {{ $labels.instance }})"
description: "Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskWriteLatency
expr: rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk write latency (instance {{ $labels.instance }})"
description: "Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostHighCpuLoad
expr: 100 - (avg by(instance) (irate(node_cpu_seconds_total{mode="idle"}[5m])) * 100) > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Host high CPU load (instance {{ $labels.instance }})"
description: "CPU load is > 80%\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostContextSwitching
expr: (rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 1000
for: 5m
labels:
severity: warning
annotations:
summary: "Host context switching (instance {{ $labels.instance }})"
description: "Context switching is growing on node (> 1000 / s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostSwapIsFillingUp
expr: (1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Host swap is filling up (instance {{ $labels.instance }})"
description: "Swap is filling up (>80%)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostSystemdServiceCrashed
expr: node_systemd_unit_state{state="failed"} == 1
for: 5m
labels:
severity: warning
annotations:
summary: "Host SystemD service crashed (instance {{ $labels.instance }})"
description: "SystemD service crashed\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostPhysicalComponentTooHot
expr: node_hwmon_temp_celsius > 75
for: 5m
labels:
severity: warning
annotations:
summary: "Host physical component too hot (instance {{ $labels.instance }})"
description: "Physical hardware component too hot\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostNodeOvertemperatureAlarm
expr: node_hwmon_temp_alarm == 1
for: 5m
labels:
severity: critical
annotations:
summary: "Host node overtemperature alarm (instance {{ $labels.instance }})"
description: "Physical node temperature alarm triggered\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostRaidArrayGotInactive
expr: node_md_state{state="inactive"} > 0
for: 5m
labels:
severity: critical
annotations:
summary: "Host RAID array got inactive (instance {{ $labels.instance }})"
description: "RAID array {{ $labels.device }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostRaidDiskFailure
expr: node_md_disks{state="fail"} > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host RAID disk failure (instance {{ $labels.instance }})"
description: "At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostKernelVersionDeviations
expr: count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1
for: 5m
labels:
severity: warning
annotations:
summary: "Host kernel version deviations (instance {{ $labels.instance }})"
description: "Different kernel versions are running\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostOomKillDetected
expr: increase(node_vmstat_oom_kill[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host OOM kill detected (instance {{ $labels.instance }})"
description: "OOM kill detected\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostEdacCorrectableErrorsDetected
expr: increase(node_edac_correctable_errors_total[5m]) > 0
for: 5m
labels:
severity: info
annotations:
summary: "Host EDAC Correctable Errors detected (instance {{ $labels.instance }})"
description: '{{ $labels.instance }} has had {{ printf "%.0f" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}'
- alert: HostEdacUncorrectableErrorsDetected
expr: node_edac_uncorrectable_errors_total > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})"
description: '{{ $labels.instance }} has had {{ printf "%.0f" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}'
- alert: HostNetworkReceiveErrors
expr: increase(node_network_receive_errs_total[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host Network Receive Errors (instance {{ $labels.instance }})"
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}'
- alert: HostNetworkTransmitErrors
expr: increase(node_network_transmit_errs_total[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host Network Transmit Errors (instance {{ $labels.instance }})"
description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} transmit errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}'
- alert: JvmMemoryFillingUp
expr: jvm_memory_bytes_used / jvm_memory_bytes_max{area="heap"} > 0.8
for: 5m
labels:
severity: warning
annotations:
summary: "JVM memory filling up (instance {{ $labels.instance }})"
description: "JVM memory is filling up (> 80%)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: SpeedtestSlowInternetDownload
expr: avg_over_time(speedtest_download[30m]) < 75
for: 5m
labels:
severity: warning
annotations:
summary: "SpeedTest Slow Internet Download (instance {{ $labels.instance }})"
description: "Internet download speed is currently {{humanize $value}} Mbps.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: SpeedtestSlowInternetUpload
expr: avg_over_time(speedtest_upload[30m]) < 20
for: 5m
labels:
severity: warning
annotations:
summary: "SpeedTest Slow Internet Upload (instance {{ $labels.instance }})"
description: "Internet upload speed is currently {{humanize $value}} Mbps.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
2.在 Prometheus 主程序目录下的prometheus.yml进行修改,引用上述告警规则
rule_files:
- "rules/*.yml"
3.重启Prometheus