服务器RAID维护相关资料

原创作品,允许转载,转载时请务必以超链接形式标明文章 原始出处 、作者信息和本声明。否则将追究法律责任。http://liubin.blog.51cto.com/282313/116046
DELL PowerEdge 2950 服务器RAID维护相关资料
DELL 服务站点:[url]www.dell.com.cn[/url]
PowerEdge 800 电话:800-858-0960
服务器编号:4KMNH2X
快速服务编码:9954499641
硬盘槽位:0,1,2,3,4,5
带光驱
操作系统:RHEL5 ,做RAID后,安装RHEL5,不用在手动加载RAID驱动
----------
开机后,部分提示信息(本提示信息是RAID相关部分,可能出现的部分状况)
press ctrl+R to run configuration utility
HA-0 (Bus 1 Dev 0) PERC 6/i integrated
Fw package:6.0.2--0002
2 virtual Driver(s) found on the host adapter
1 virtual Driver(s) Degraded
2 virtual Driver(s) handled by BIOS
foreign configuration(s) found on adapter
press any key to continue or 'C' load the configuration utility or 'F' to import foreign configuration (s) and continue
按CTRL+R 后出现的界面大致如下:
PERC 6/i integrated BIOS configuration utility
VD mgmt PD mgmt Ctrl mgmt Foreign view
-----
F1- help F2-operation F5-Refresh Ctrl-N -Nextpage Ctrl -p prev-page F12-ctlr
常用选项内容:
VD 
  controller0
       diskgroup 0
           virtual disk 1
           physical disk 
              --:--:04
           space allocation
              virtual disk 1
           hot spares
       diskgroup 1
           ........
           ........
           ........
           ........
PD mgmt
prive ID Vendor size/mb type state DG
--:--:0 ATA xxxxx xxxx online 01
--:--:1 ATA xxxxx xxxx online 01
--:--:2 ATA xxxxx xxxx foreign
--:--:3 ATA xxxxx xxxx rebuild
--;--:4 ATA xxxxx xxxx online 02
在以下选中位置按F2后,出现的内容:
controller 0
create new VD
reset config
foreign config -----> import
clear
disk group 0
manage Ded .HS----> Dedicated Hotspare for disk group 0
Delete Disk group
virtual disk 0
initialization
consistency check
delete VD
properties
PD mgmt 页面中,选中某行后,
rebuild
CED blinking
force online
force offline
make global HS
remove hot spare
--------------------------
故障实例:
1、RAID5 一块硬盘掉线
2950 在0,1,2 三个硬盘槽位分别接入了 ST 1TB SATA 硬盘,配置成RAID 5 。
开机后发现有一块硬盘指示灯不亮,显示器上并提示如下:
some configured disks have been removed from your system or are no longer accessible.
please check you cables and also ensure all disk are present.press any key to continue,or
'C' to load the configuration utility.
按 键盘 上的 C 键后,出现提示如下:
Entering the configuration uility in this state will result in drive configuration changes .press 'Y' to continue loading the configuration utility or power off your system
and check your cables to ensure all disk are present and reboot
按 键盘 上的 Y 键后
进入RAID配置界面,没有看到在1 号位的 硬盘,提示:MISSING ,RAID 5 状态为
Degraded
然后重启机器后,发现 原来指示灯不亮的硬盘,指示灯开始变为橙色,后又变成绿色
提示:
Fw package:6.0.2--0002
2 virtual Driver(s) found on the host adapter
1 virtual Driver(s) Degraded
2 virtual Driver(s) handled by BIOS
foreign configuration(s) found on adapter
press any key to continue or 'C' load the configuration utility or 'F' to import foreign configuration (s) and continue
然后,在RAID配置界面里将掉线的,导入。后恢复正常后,不久该硬盘又掉线,怀疑硬盘有问题。导入的时间将近4个小时,数据量2G多,硬盘上就光一个RHEL5 定制的系统
--------------
RAID 5 更换1块坏硬盘。0,1,2 三块插槽位配置RAID5 。1插槽位的驱动器状态由绿变橙。预报警。现更换1 处的硬盘。
方法1、
在开机状态,机器正常运行情况下,取下有问题的硬盘后,在接入新的同型号,同容量大小的硬盘,此时,可观察到,0,3 插槽位的硬盘指示状态灯亮绿色,活动状态灯绿色闪烁。1插槽位硬盘指示状态灯绿色闪烁,活动状态灯不亮。此时,1 插槽位的硬盘正在重建数据。等0,1,2 驱动器硬盘指示状态等全绿,稳定亮起时。RAID 5 重建完成
方法2、
关机,取下坏硬盘。在接入新的同型号,同容量大小的硬盘。开机,后 进入 RAID的配置界面,在 手工 重建 新硬盘的数据
posted @ 2011-09-28 11:19  有容乃大  阅读(7199)  评论(0编辑  收藏  举报