Exadata X3-2刷机至20.1.22.0.0版本时,Imaging process entered in an interactive mode
一套Exadata X3-2 1/4配置,计划将image版本重新刷机到20.1.22.0.0版本。刷了两个小时竟然还没刷完,登录console查看日志,发现imaging进程进入到了交互模式。
[INFO ] [ERROR] Validation test(s) FAILED for the post imaging mode
[INFO ] Choose from following by typing letter in '()':
(c)ontinue anyway.
Normal reboot procedure will be initiated,
e(n)ter interactive diagnostics shell.
The system is prepared for the normal reboot,
but you have a chance to go to the shell.
You will need credentials from Oracle support to login,
(r)emove installation and power off machine,
[ERROR ] [FACTORY_ERROR] Imaging is going interactive
Select: c
[FACTORY_ERROR] Imaging process entered in an interactive mode. Function ask_yes_no
Are you sure (y/n) [n]:
搜索MOS,未找到完全匹配的案例。此时只能尝试选择C,继续安装,之后能继续imaging操作,刷机成功。