dell服务器raid管理工具
lsiutil dell sas6i/r
MegaCli dell prec
omsa管理raid分区
显示物理硬盘信息
omreport storage pdisk controller=0
显示虚拟硬盘信息
omreport storage vdisk controller=0
配置物理硬盘为raid模式(查看物理硬盘信息,如果非raid模式,使用以下命令)
omconfig storage pdisk controller=0 action=convertnonraidtoraid pdisk=0:1:0
omconfig storage pdisk controller=0 action=convertnonraidtoraid pdisk=0:1:1
.....
配置物理硬盘为raid10模式
omconfig storage controller action=createvdisk controller=0 raid=r10 size=max pdisk=0:1:0,0:1:1,0:1:2,0:1:3,0:1:4,0:1:5,0:1:6,0:1:7,0:1:8,0:1:9,0:1:10,0:1:11
删除虚拟硬盘
omconfig storage vdisk action=deletevdisk vdisk=1 controller=0
清除硬盘Foreign状态
mconfig storage controller action=clearforeignconfig controller=0
How-To : Replace dead / faulty drive in Dell PERC RAID array
http://cavepopo.hd.free.fr/wordpress/how-to/how-to-replace-dead-faulty-drive-in-dell-perc-raid-array/
# raidcfg controller
Controller_ID/Slot_ID: 4
Controller_PCI_ID: 2:0:0
Controller_Name: PERC H200 Integrated
Channels: 2
No.of Virtual_Disks: 2
Array_Disks: 0:0:2,0:1:2,0:2:2,0:3:2,0:4:2,0:5:2,0:6:2,0:7:2,
0:8:2,0:9:2,0:12:2,0:13:2
Firmware Version: 07.03.05.00
Preserved Cache: Not Available
T10 Protection Info Capable: No
Encryption Capable: No
Encryption Key Present: Not Applicable
# raidcfg controller controllerid=4
# raidcfg pdisk controllerid=4
Controller: PERC H200 Integrated
**************** Physical Drive ****************
Vendor: DELL(tm)
Model: WDC WD2003FYYS-18W0B0
Protocol: SATA
Media: HDD
NegSpeed: 3072 Mbps
CapSpeed: UNKNOWN
Certified: YES
Location: 0:0:2
Size: 1907200 MB (1862 GB)
Avail: 0 MB
SMARTState: No Error
DiskState: Online
Encryption Capable: No
Secured: Not Applicable
Sector Size: 512B
T10 Protection Info Capable: No
**************** Physical Drive ****************
Vendor: DELL(tm)
Model: WDC WD2003FYYS-18W0B0
Protocol: SATA
Media: HDD
NegSpeed: 3072 Mbps
CapSpeed: UNKNOWN
Certified: YES
Location: 0:1:2
Size: 1907200 MB (1862 GB)
Avail: 0 MB
SMARTState: No Error
DiskState: Online
Encryption Capable: No
Secured: Not Applicable
Sector Size: 512B
T10 Protection Info Capable: No
# raidcfg vdisk controllerid=4
Controller: PERC H200 Integrated
VDisk ID: 1
Virtual Disk Name: Virtual Disk 1
Size: 9536000 MB (9312 GB)
Type: RAID 10
Read Policy: Not Applicable
Write Policy: Not Applicable
Cache Policy: Disabled
Stripe Size: 64
Span Length: 10
Drives: 0:0:2,0:1:2,0:2:2,0:3:2,0:4:2,0:5:2,0:6:2,0:7:2,
0:8:2,0:9:2
BootVD: No
T10 Protection Info: Disabled
Encrypted: No
VDisk ID: 0
Virtual Disk Name: Virtual Disk 0
Size: 476416 MB (465 GB)
Type: RAID 1
Read Policy: Not Applicable
Write Policy: Not Applicable
Cache Policy: Disabled
Stripe Size: 64
Drives: 0:12:2,0:13:2
BootVD: No
T10 Protection Info: Disabled
Encrypted: No
raidcfg vdisk action=deletevdisk controllerid=4 vdisk=1
raidcfg controller action=createvdisk controllerid=4 pdisk=0:0:2,0:1:2,0:2:2,0:3:2,0:4:2,0:5:2,0:6:2,0:7:2,0:8:2,0:9:2 raid=5
【推荐】国内首个AI IDE,深度理解中文开发场景,立即下载体验Trae
【推荐】编程新体验,更懂你的AI,立即体验豆包MarsCode编程助手
【推荐】抖音旗下AI助手豆包,你的智能百科全书,全免费不限次数
【推荐】轻量又高性能的 SSH 工具 IShell:AI 加持,快人一步
· .NET Core 中如何实现缓存的预热?
· 从 HTTP 原因短语缺失研究 HTTP/2 和 HTTP/3 的设计差异
· AI与.NET技术实操系列:向量存储与相似性搜索在 .NET 中的实现
· 基于Microsoft.Extensions.AI核心库实现RAG应用
· Linux系列:如何用heaptrack跟踪.NET程序的非托管内存泄露
· TypeScript + Deepseek 打造卜卦网站:技术与玄学的结合
· 阿里巴巴 QwQ-32B真的超越了 DeepSeek R-1吗?
· 【译】Visual Studio 中新的强大生产力特性
· 【设计模式】告别冗长if-else语句:使用策略模式优化代码结构
· AI与.NET技术实操系列(六):基于图像分类模型对图像进行分类