TJA1020应用笔记(AN00093)
1. it is dissuaded to connect NSLP directly to a VCC supply source.
NSLP最好不要与VCC直接连接。
2. (NLSP pin)The range of the input threshold is chosen to support 5 V as well as 3.0 V/3.3 V supplied devices.
NLSP pin输入电压 3V/3.3V/5V
3. The local wake-up input NWAKE is used to detect local wake-up events using a falling edge.
本地唤醒输入NWAKE用来检测本地唤醒事件(下降沿)
4. The modes of the TJA1020 are controlled by the pins NSLP and TXD.
TJA1020的模式由NLSP和TXD来控制。