存储服务器raid卡信息解读

                                     
Adapter #0

==============================================================================
                    Versions
                ================
Product Name    : AVAGO MegaRAID SAS 9364-8i
Serial No       : SPA0568230
FW Package Build: 24.21.0-0148

                    Mfg. Data
                ================
Mfg. Date       : 02/05/20
Rework Date     : 00/00/00
Revision No     : 05B
Battery FRU     : N/A

                Image Versions in Flash:
                ================
BIOS Version       : 6.36.00.3_4.19.08.00_0x06180205
FW Version         : 4.680.00-8555
NVDATA Version     : 3.1705.00-0024
Ctrl-R Version     : 5.19-0606
Preboot CLI Version: 01.07-05:#%0000
Boot Block Version : 3.07.00.00-0004

                Pending Images in Flash
                ================
None

                PCI Info
                ================
Controller Id   : 0000
Vendor Id       : 1000
Device Id       : 005d
SubVendorId     : 1000
SubDeviceId     : 936a

Host Interface  : PCIE

ChipRevision    : C0

Link Speed           : 3 
Number of Frontend Port: 0 
Device Interface  : PCIE

Number of Backend Port: 8 
Port  :  Address
0        56c92bf004248d3f 
1        0000000000000000 
2        0000000000000000 
3        0000000000000000 
4        0000000000000000 
5        0000000000000000 
6        0000000000000000 
7        0000000000000000 

                HW Configuration
                ================
SAS Address      : 500605b00abca1f0
BBU              : Absent
Alarm            : Present
NVRAM            : Present
Serial Debugger  : Present
Memory           : Present
Flash            : Present
Memory Size      : 2048MB
TPM              : Absent
On board Expander: Absent
Upgrade Key      : Absent
Temperature sensor for ROC    : Present
Temperature sensor for controller    : Absent

ROC temperature : 70  degree Celsius

                Settings
                ================
Current Time                     : 2:54:19 8/27, 2024
Predictive Fail Poll Interval    : 300sec
Interrupt Throttle Active Count  : 16
Interrupt Throttle Completion    : 50us
Rebuild Rate                     : 30%
PR Rate                          : 30%
BGI Rate                         : 30%
Check Consistency Rate           : 30%
Reconstruction Rate              : 30%
Cache Flush Interval             : 4s
Max Drives to Spinup at One Time : 2
Delay Among Spinup Groups        : 12s
Physical Drive Coercion Mode     : Disabled
Cluster Mode                     : Disabled
Alarm                            : Enabled
Auto Rebuild                     : Enabled
Battery Warning                  : Enabled
Ecc Bucket Size                  : 15
Ecc Bucket Leak Rate             : 1440 Minutes
Restore HotSpare on Insertion    : Disabled
Expose Enclosure Devices         : Enabled
Maintain PD Fail History         : Enabled
Host Request Reordering          : Enabled
Auto Detect BackPlane Enabled    : SGPIO/i2c SEP
Load Balance Mode                : Auto
Use FDE Only                     : No
Security Key Assigned            : No
Security Key Failed              : No
Security Key Not Backedup        : No
Default LD PowerSave Policy      : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 10 
Auto Enhanced Import             : Yes
Any Offline VD Cache Preserved   : No
Allow Boot with Preserved Cache  : No
Disable Online Controller Reset  : No
PFK in NVRAM                     : Yes
Use disk activity for locate     : No
POST delay                       : 90 seconds
BIOS Error Handling              : Safe Mode on Errors
Current Boot Mode                 :Normal
                Capabilities
                ================
RAID Level Supported             : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives                 : SAS, SATA

Allowed Mixing:

Mix in Enclosure Allowed
Mix of SAS/SATA of HDD type in VD Allowed
Mix of SAS/SATA of SSD type in VD Allowed
Mix of SSD/HDD in VD Allowed

                Status
                ================
ECC Bucket Count                 : 139

                Limitations
                ================
Max Arms Per VD          : 32 
Max Spans Per VD         : 8 
Max Arrays               : 128 
Max Number of VDs        : 64 
Max Parallel Commands    : 928 
Max SGE Count            : 60 
Max Data Transfer Size   : 512 sectors 
Max Strips PerIO         : 128 
Max LD per array         : 16 
Min Strip Size           : 64 KB
Max Strip Size           : 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade      : 0 GB
Current Size of FW Cache       : 1698 MB

                Device Present
                ================
Virtual Drives    : 2 
  Degraded        : 0 
  Offline         : 0 
Physical Devices  : 37 
  Disks           : 35 
  Critical Disks  : 0 
  Failed Disks    : 0 

                Supported Adapter Operations
                ================
Rebuild Rate                    : Yes
CC Rate                         : Yes
BGI Rate                        : Yes
Reconstruct Rate                : Yes
Patrol Read Rate                : Yes
Alarm Control                   : Yes
Cluster Support                 : No
BBU                             : Yes
Spanning                        : Yes
Dedicated Hot Spare             : Yes
Revertible Hot Spares           : Yes
Foreign Config Import           : Yes
Self Diagnostic                 : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares               : Yes
Deny SCSI Passthrough           : No
Deny SMP Passthrough            : No
Deny STP Passthrough            : No
Support Security                : No
Snapshot Enabled                : No
Support the OCE without adding drives : Yes
Support PFK                     : Yes
Support PI                      : Yes
Support Boot Time PFK Change    : No
Disable Online PFK Change       : No
Support LDPI Type1                      : No
Support LDPI Type2                      : No
Support LDPI Type3                      : No
PFK TrailTime Remaining         : 0 days 0 hours
Support Shield State            : Yes
Block SSD Write Disk Cache Change: Yes
Support Online FW Update        : Yes

                Supported VD Operations
                ================
Read Policy          : Yes
Write Policy         : Yes
IO Policy            : Yes
Access Policy        : Yes
Disk Cache Policy    : Yes
Reconstruction       : Yes
Deny Locate          : No
Deny CC              : No
Allow Ctrl Encryption: No
Enable LDBBM         : Yes
Support Breakmirror  : Yes
Power Savings        : No

                Supported PD Operations
                ================
Force Online                            : Yes
Force Offline                           : Yes
Force Rebuild                           : Yes
Deny Force Failed                       : No
Deny Force Good/Bad                     : No
Deny Missing Replace                    : No
Deny Clear                              : No
Deny Locate                             : No
Support Temperature                     : Yes
NCQ                                     : Yes
Disable Copyback                        : No
Enable JBOD                             : No
Enable Copyback on SMART                : No
Enable Copyback to SSD on SMART Error   : Yes
Enable SSD Patrol Read                  : No
PR Correct Unconfigured Areas           : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares         : No
Spin Down time                          : 30 
T10 Power State                         : No
                Error Counters
                ================
Memory Correctable Errors   : 270 
Memory Uncorrectable Errors : 0 

                Cluster Information
                ================
Cluster Permitted     : No
Cluster Active        : No

                Default Settings
                ================
Phy Polarity                     : 0 
Phy PolaritySplit                : 0 
Background Rate                  : 30 
Strip Size                       : 256kB
Flush Time                       : 4 seconds
Write Policy                     : WB
Read Policy                      : RA
Cache When BBU Bad               : Disabled
Cached IO                        : No
SMART Mode                       : Mode 6
Alarm Disable                    : Yes
Coercion Mode                    : None
ZCR Config                       : Unknown
Dirty LED Shows Drive Activity   : No
BIOS Continue on Error           : 3 
Spin Down Mode                   : None
Allowed Device Type              : SAS/SATA Mix
Allow Mix in Enclosure           : Yes
Allow HDD SAS/SATA Mix in VD     : Yes
Allow SSD SAS/SATA Mix in VD     : Yes
Allow HDD/SSD Mix in VD          : Yes
Allow SATA in Cluster            : No
Max Chained Enclosures           : 16 
Disable Ctrl-R                   : No
Enable Web BIOS                  : No
Direct PD Mapping                : No
BIOS Enumerate VDs               : Yes
Restore Hot Spare on Insertion   : No
Expose Enclosure Devices         : Yes
Maintain PD Fail History         : Yes
Disable Puncturing               : No
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled              : No
LED Show Drive Activity          : No
Cluster Disable                  : Yes
SAS Disable                      : No
Auto Detect BackPlane Enable     : SGPIO/i2c SEP
Use FDE Only                     : No
Enable Led Header                : Yes
Delay during POST                : 0 
EnableCrashDump                  : Yes
Disable Online Controller Reset  : No
EnableLDBBM                      : Yes
Un-Certified Hard Disk Drives    : Allow
Treat Single span R1E as R10     : No
Max LD per array                 : 16
Power Saving option              : Don't Auto spin down Configured Drives
Max power savings option is  not allowed for LDs. Only T10 power conditions are to be used.
Default spin down time in minutes: 30 
Enable JBOD                      : No
TTY Log In Flash                 : No
Auto Enhanced Import             : Yes
BreakMirror RAID Support         : Yes
Disable Join Mirror              : Yes
Enable Shield State              : Yes
Time taken to detect CME         : 60s

Exit Code: 0x00

以下是GPT给出的解读信息

你提供的信息显示了你的服务器上安装了一块 AVAGO MegaRAID SAS 9364-8i 阵列卡。这些详细信息说明了阵列卡的固件版本、PCI接口信息、支持的RAID级别、驱动器信息和其他配置。

如何检查阵列卡是否正在工作

  1. 检查物理设备和虚拟磁盘状态
    根据输出,控制器上有 35 个物理磁盘连接,并且所有磁盘都处于正常状态(没有关键磁盘或失败的磁盘)。另外,有两个虚拟磁盘,它们的状态也都正常(无降级或离线状态)。

    Virtual Drives    : 2 
      Degraded        : 0 
      Offline         : 0 
    Physical Devices  : 37 
      Disks           : 35 
      Critical Disks  : 0 
      Failed Disks    : 0 
    
  2. 检查 RAID 阵列状态
    如果所有虚拟磁盘(Virtual Drives)均未降级(Degraded)或离线(Offline),则表明 RAID 阵列工作正常。

  3. 温度和硬件状态
    ROC(RAID on Chip)温度为 70 摄氏度,这是一个合理的温度,但也需要监控以确保不超过安全温度范围。

    ROC temperature : 70  degree Celsius
    

如何使用命令行重做硬 RAID 5

如果你打算重新配置 RAID 5 阵列,请确保备份所有重要数据。以下是重新配置 RAID 5 阵列的一般步骤:

  1. 删除现有虚拟磁盘

    • 使用 storclimegacli 等工具删除现有的虚拟磁盘。

    示例命令(storcli):

    sudo storcli /c0/v0 delete force
    

    替换 /c0/v0 为你的控制器和虚拟磁盘编号。

  2. 创建新的 RAID 5 阵列

    • 使用相同的工具来创建一个新的 RAID 5 阵列。

    示例命令(storcli):

    sudo storcli /c0 add vd r5 drives=0-4
    

    以上命令将在控制器 c0 上使用物理驱动器 0-4 创建一个新的 RAID 5 阵列。根据你的需求调整驱动器编号。

  3. 确认新配置

    • 创建新阵列后,检查 RAID 阵列的状态以确保它已正确配置。

    示例命令(storcli):

    sudo storcli /c0 show
    

额外建议

  • 查看文档和支持信息:在执行 RAID 相关操作之前,最好查看 AVAGO MegaRAID SAS 9364-8i 的官方文档,以获取特定于设备的指导。
  • 监控阵列状态:定期使用监控命令检查阵列的状态和健康状况,及时处理任何潜在问题。

通过这些步骤和建议,你应该能够成功重做你的 RAID 5 阵列并确保阵列卡和磁盘的正常运行。

posted @ 2024-08-28 15:38  jasmine456  阅读(35)  评论(0编辑  收藏  举报