一、实验目的
能够独立部署RYU控制器;
能够理解RYU控制器实现软件定义的集线器原理;
能够理解RYU控制器实现软件定义的交换机原理。
二、实验环境
(一)基本要求
下载虚拟机软件Oracle VisualBox或VMware;
在虚拟机中安装Ubuntu 20.04 Desktop amd64,并完整安装Mininet;
(二)、实验要求
1.搭建下图所示SDN拓扑,协议使用Open Flow 1.0,并连接Ryu控制器
- 在对应文件夹下执行
ryu-manager gui_topology.py --observe-links
启动控制器
使用以下命令搭建拓扑
sudo mn --topo=single,3 --mac --controller=remote,ip=127.0.0.1,port=6633 --switch ovsk,protocols=OpenFlow10
2.通过Ryu的图形界面查看网络拓扑
3.阅读Ryu文档的The First Application一节,运行并使用 tcpdump 验证L2Switch,分析和POX的Hub模块有何不同
- 创建L2Switch.py文件,并保存在目录/home/用户名/学号/lab6/中
from ryu.base import app_manager
from ryu.controller import ofp_event
from ryu.controller.handler import MAIN_DISPATCHER
from ryu.controller.handler import set_ev_cls
from ryu.ofproto import ofproto_v1_0
class L2Switch(app_manager.RyuApp):
OFP_VERSIONS = [ofproto_v1_0.OFP_VERSION]
def __init__(self, *args, **kwargs):
super(L2Switch, self).__init__(*args, **kwargs)
@set_ev_cls(ofp_event.EventOFPPacketIn, MAIN_DISPATCHER)
def packet_in_handler(self, ev):
msg = ev.msg
dp = msg.datapath
ofp = dp.ofproto
ofp_parser = dp.ofproto_parser
actions = [ofp_parser.OFPActionOutput(ofp.OFPP_FLOOD)]
data = None
if msg.buffer_id == ofp.OFP_NO_BUFFER:
data = msg.data
out = ofp_parser.OFPPacketOut(
datapath=dp, buffer_id=msg.buffer_id, in_port=msg.in_port,
actions=actions, data = data)
dp.send_msg(out)
- 执行命令
ryu-manager L2Switch.py
- 重新创建拓扑
sudo mn --topo=single,3 --mac --controller=remote,ip=127.0.0.1,port=6633 --switch ovsk,protocols=OpenFlow10
-
再利用mininet的xterm开启h1,h2,h3的命令行终端,并在h2和h3使用开启抓包(抓取eth0端口)
-
在h2主机终端中输入
tcpdump -nn -i h2-eth0
- 在h3主机终端中输入
tcpdump -nn -i h3-eth0
- h1 ping h2 注: 在h1的窗口输入
ping 10.0.0.2
- h1 ping h3
由图可见,h1 ping h2时h3也能收到数据包,h1 ping h3时h2也能收到数据包,说明L2Switch模块的功能同hub模块:为每一个交换机建立通配的洪泛规则,让交换机拥有集线器的功能
-
分析和POX的Hub模块有何不同
1.结合拓扑,分别运行ryu和运行pox(Hub模块)
ryu-manager L2Switch.py
./pox.py log.level --DEBUG forwarding.hub
2.查看拓扑下发流表
dpctl dump-flows
3.无法查看L2Switch下发的流表
4.而hub模块下发的流表可以查看
4.继下面的.py文件一起,先执行.py文件再创拓扑
sudo mn --topo=single,3 --mac --controller=remote,ip=127.0.0.1,port=6633 --switch ovsk,protocols=OpenFlow13
编程修改L2Switch.py,另存为L2xxxxxxxxx.py,使之和POX的Hub模块的变得一致(xxxxxxxxx为学号)
from ryu.base import app_manager
from ryu.ofproto import ofproto_v1_3
from ryu.controller import ofp_event
from ryu.controller.handler import MAIN_DISPATCHER, CONFIG_DISPATCHER
from ryu.controller.handler import set_ev_cls
class hub(app_manager.RyuApp):
OFP_VERSIONS = [ofproto_v1_3.OFP_VERSION]
def __init__(self, *args, **kwargs):
super(hub, self).__init__(*args, **kwargs)
@set_ev_cls(ofp_event.EventOFPSwitchFeatures, CONFIG_DISPATCHER)
def switch_feathers_handler(self, ev):
datapath = ev.msg.datapath
ofproto = datapath.ofproto
ofp_parser = datapath.ofproto_parser
# install flow table-miss flow entry
match = ofp_parser.OFPMatch()
actions = [ofp_parser.OFPActionOutput(ofproto.OFPP_CONTROLLER, ofproto.OFPCML_NO_BUFFER)]
# 1\OUTPUT PORT, 2\BUFF IN SWITCH?
self.add_flow(datapath, 0, match, actions)
def add_flow(self, datapath, priority, match, actions):
# 1\ datapath for the switch, 2\priority for flow entry, 3\match field, 4\action for packet
ofproto = datapath.ofproto
ofp_parser = datapath.ofproto_parser
# install flow
inst = [ofp_parser.OFPInstructionActions(ofproto.OFPIT_APPLY_ACTIONS, actions)]
mod = ofp_parser.OFPFlowMod(datapath=datapath, priority=priority, match=match, instructions=inst)
datapath.send_msg(mod)
@set_ev_cls(ofp_event.EventOFPPacketIn, MAIN_DISPATCHER)
def packet_in_handler(self, ev):
msg = ev.msg
datapath = msg.datapath
ofproto = datapath.ofproto
ofp_parser = datapath.ofproto_parser
in_port = msg.match['in_port'] # get in port of the packet
# add a flow entry for the packet
match = ofp_parser.OFPMatch()
actions = [ofp_parser.OFPActionOutput(ofproto.OFPP_FLOOD)]
self.add_flow(datapath, 1, match, actions)
# to output the current packet. for install rules only output later packets
out = ofp_parser.OFPPacketOut(datapath=datapath, buffer_id=msg.buffer_id, in_port=in_port, actions=actions)
# buffer id: locate the buffered packet
datapath.send_msg(out)
(三)实验报告
收获总结
在创建拓扑出现Unable to contact the remote controller at 127.0.0.1:6633
解决方法:先连接Ryu控制器再创建拓扑
遇到拓扑不能pingall
解决方法:关掉拓扑,启动L2Switch模块后再创建拓扑
心得
实验难度中等,实验内容和实验5POX相似。本来看了别人的博客很担心Ryu的安装会出现问题,但是按照老师所给的指令执行之后就顺利地安装了,但是不知道和这个软件有没有关系,安装之后就没法像之前一样执行mn相关的指令了,不知道跟环境变量有没有关系,所以干脆卸载重装mininet了。刚开始做实验时并不知道该先开控制器还是先创建拓扑,就先创建了拓扑,做到最后发现ping不通(最后ping不通其实也不是因为前面的原因),看了同学的博客才发现应该先开控制器。后来做第4小题的时候,还是使用的第2小题创建的拓扑,然后启动
L2Switch模块,发现ping不通,重启之后重做了前面的部分(先开控制器)发现ping通了但是查看流表的时候并没有大家说的那样看不见流表,而实给出了流表,说明这个拓扑并没有受到L2Switch1的作用。于是我就开始浏览同学们的博客,后来发现第4小题也是应该先开L2Switch模块并且Switch模块应该放在保存在目录/home/用户名/学号/lab6/下,而我之前放错了位置,改正了这些错误之后就成功ping通并且也达到了查看不到流表的效果,说明成功了。