QQ在线咨询

storcli工具的使用方法

个人博客:点击这里进入

常用命令:(c代表Controller e代表Enclosures代表SlotPDv代表ld

/opt/MegaRAID/storcli/storcli64 -v    显示软件版本信息

/opt/MegaRAID/storcli/storcli64 -h    查看帮助信息

/opt/MegaRAID/storcli/storcli64 show    查看RAID卡、系统内核、主机名等信息

/opt/MegaRAID/storcli/storcli64 /c0 show    查看RAID卡、物理盘、逻辑盘等详细信息

/opt/MegaRAID/storcli/storcli64 /c0 /ex /sx set jbod 设置slot x物理盘状态为JBOD

/opt/MegaRAID/storcli/storcli64 /c0 /ex /sx set good force 设置slot x物理盘状态为UGood

/opt/MegaRAID/storcli/storcli64 /c0 /eall /sall show all     查看RAID卡上所有物理磁盘详细信息

/opt/MegaRAID/storcli/storcli64 /c0 /vall show all查看RAID卡上所有逻辑盘详细信息,也可指定某个逻辑磁盘v0v1

/opt/MegaRAID/storcli/storcli64 /c0 /v0 show     显示第一块RAID卡上第一个逻辑磁盘信息

/opt/MegaRAID/storcli/storcli64 /c0 /e252 /s0 start locate 定位第一块RAID上某块物理磁盘,物理磁盘的绿色的定位灯会被点亮。

/opt/MegaRAID/storcli/storcli64 /c0  /ex /sx stop locate    停止定位,定位灯停止闪烁。

/opt/MegaRAID/storcli/storcli64 /c0 download file=mr3108fw.rom    升级第一块RAID卡固件

/opt/MegaRAID/storcli/storcli64 /c0 restart    升级固件后重启RAID卡以便新固件及时生效

/opt/MegaRAID/storcli/storcli64 /c0 add vd r0 size=all name=R0 drives=217:3,13 awb nora cached strip=256 Slot号为313的物理盘创建全容量Raid 0,读写策略为no read ahead/ always writebackIO策略为Cached,条带大小为256k(详细参数可以使用storcli64 /c0 add vd help查看及使用)

/opt/MegaRAID/storcli/storcli64 /c0 add vd r10 size=10gb name=R10 drives=217:2-3,13,34 pdperarray=2 wb direct strip=64 Slot号为231334的物理盘创建10gb容量的raid 10,读写策略为read ahead/ writebackIO策略为Direct,条带大小为64k(注意:LSI SAS3108最多支持64RAID,创建10/50/60时,必须指定pdperarray参数。如果没有这个参数,是创建不成功的。)

/opt/MegaRAID/storcli/storcli64 /c0 add vd r10 size=10gb,11gb name=R10-1,R10-2 drives=217:2-3,13,34 pdperarray=2 wb direct strip=64 一次性在Slot号为231334的物理盘上创建容量为10gb名为R10-1、容量为11gb名为R10-2的两个raid10逻辑盘

/opt/MegaRAID/storcli/storcli64 /c0 /v0 del [force] 删除ID0的逻辑盘

/opt/MegaRAID/storcli/storcli64 /c0 /ex /sx add hotsparedrive dgs=0    设置某块物理磁盘为磁盘组0的热备盘,如果不指定dgs,则为该RAID卡上全局热备盘。

/opt/MegaRAID/storcli/storcli64 /c0 /ex /sx delete hotsparedrive    删除热备磁盘

/opt/MegaRAID/storcli/storcli64 /c0 /vx set wrcache=wt/wb/awb 设置Vx逻辑盘写策略

/opt/MegaRAID/storcli/storcli64 /c0 /vx set rdcache=ra/nora 设置Vx逻辑盘读策略

/opt/MegaRAID/storcli/storcli64 /c0 /vx set accesspolicy=rw/ro/blocked 设置访问权限

/opt/MegaRAID/storcli/storcli64 /c0 /vx set iopolicy=cached/direct 设置IO策略

/opt/MegaRAID/storcli/storcli64 /c0 show rebuildrate    查看第一块RAIDrebuildrate速度

/opt/MegaRAID/storcli/storcli64 /c0 flushcache     清除第一块RAID卡缓存

/opt/MegaRAID/storcli/storcli64 /c0 /e217 /sall show rebuild  查看磁盘重建进度

/opt/MegaRAID/storcli/storcli64 /c0 /ex /sx start rebuild    开始重建

/opt/MegaRAID/storcli/storcli64 /c0 /ex /sx stop rebuild    停止重建

/opt/MegaRAID/storcli/storcli64 /c0 /bbu show all   显示bbu信息

/opt/MegaRAID/storcli/storcli64 /c0 show alarm    查看报警器信息

/opt/MegaRAID/storcli/storcli64 /c0 set alarm=silence   暂时关闭报警器鸣叫

/opt/MegaRAID/storcli/storcli64 /c0 set alarm=off       始终关闭报警器鸣叫

/opt/MegaRAID/storcli/storcli64 /c0 /e252 /s3 start initialization    初始化某个物理磁盘

/opt/MegaRAID/storcli/storcli64 /c0 /e252 /s3 show initialization    查看某个初始化的物理磁盘进度

/opt/MegaRAID/storcli/storcli64 /c0 set eghs state=on eug=off smarter=on 设置紧急策略生效类型,state=on代表热配盘生效,eug=on代表UGood盘生效,smarter代表回拷

/opt/MegaRAID/storcli/storcli64 /c0 /fall show   查看foreign信息

/opt/MegaRAID/storcli/storcli64 /c0 /fall import    导入foreign

/opt/MegaRAID/storcli/storcli64 /c0 /fall del    清除foreign

/opt/MegaRAID/storcli/storcli64 /c0 show termlog type=contents       在线查看日志

/opt/MegaRAID/storcli/storcli64 /c0 show termlog type=contents | grep "rebuild"    在线查看日志抽取关键字

/opt/MegaRAID/storcli/storcli64 /c0 show termlog >filename.txt 保存FW日志到指定文件

/opt/MegaRAID/storcli/storcli64 /c0 show events >filename.txt 保存事件日志到指定文件

 