MySQL Hardware--RAID卡常用信息查看

MegaRAID信息查看

#查raid卡信息(生产商、电池信息及所支持的raid级别)
/usr/local/sbin/MegaCli -AdpAllInfo -aALL |grep -E "Product Name|BBU|Memory Size|RAID Level Supported"

#查看虚拟化(vd)和物理盘(pd)的信息,比如查看物理硬盘数,是否有硬盘offline或者degraded
/usr/local/sbin/MegaCli -AdpAllInfo -aALL |grep -E "Device Present" -A9

## 查看RAID日志
/usr/local/sbin/MegaCli -FwTermLog dsply –aAll

#查看硬盘是否online
/usr/local/sbin/MegaCli -PDList -aALL |grep "Firmware state"

#查看硬盘是否存在物理错误(error不为0,可能会有硬盘故障即将发生)
/usr/local/sbin/MegaCli -PDList -aALL |grep -i error

#查看电池信息(电池类型、电池状态、充电状态、温度等)
/usr/local/sbin/MegaCli -AdpBbuCmd -aAll

#raid卡个数
/usr/local/sbin/MegaCli -adpCount

#显示所有逻辑磁盘组信息(做了几组raid,raid cache的默认和当前策略,做好raid后的虚拟盘容量)
/usr/local/sbin/MegaCli -LDInfo -LALL -aAll

#显示所有物理盘(物理磁盘个数、大小、是否存在error)
/usr/local/sbin/MegaCli -PDList -aAll

#显示所有物理盘物理错误
/usr/local/sbin/MegaCli -PDList -aAll |grep -i error

#查看充电状态
/usr/local/sbin/MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep 'Charger Status'

##查看BBU设置
/usr/local/sbin/MegaClii -AdpBbuCmd -GetBbuProperties -aALL

## 查看当前BBU状态
/usr/local/sbin/MegaClii -AdpBbuCmd -GetBbuStatus -aALL

#显示BBU状态信息,比如电池是否,如果issohgood为Yes为正常,No为异常
/usr/local/sbin/MegaCli -AdpBbuCmd -GetBbuStatus -aALL|grep -i issohgood

#显示Raid卡型号,cache大小、Raid设置,cache策略、Disk相关信息
/usr/local/sbin/MegaCli -cfgdsply -aALL |egrep "PDs|VDs|Product Name|Memory|BBU:"

#磁带状态的变化,从拔盘,到插盘的过程中。
Device |Normal|Damage|Rebuild|Normal
Virtual Drive |Optimal|Degraded|Degraded|Optimal
Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online

#查看磁盘缓存策略(查看vd的)
/usr/local/sbin/MegaCli -LDGetProp -Cache -LALL -aALL

#或者(查看pd的)

#/usr/local/sbin/MegaCli -LDGetProp -DskCache -LALL -aALL

#缓存策略解释:

WT (Write through
WB (Write back)
NORA (No read ahead)
RA (Read ahead)
ADRA (Adaptive read ahead)
Cached
Direct
例子:

#查看物理磁盘重建进度
/usr/local/sbin/MegaCli -PDRbld -ShowProg -PhysDrv [1:5] -a0
或者以动态可视化文字界面显示
/usr/local/sbin/MegaCli -PDRbld -ProgDsply -PhysDrv [1:5] -a0

#磁带状态的变化,从拔盘,到插盘的过程中:
Device |Normal|Damage|Rebuild|Normal
Virtual Drive |Optimal|Degraded|Degraded|Optimal
Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online

 

HP RAID信息查看

## 查看控制器编号
hpacucli ctrl all show status |egrep 'Smart Array'

## 看出slot=0控制卡的信息
hpacucli ctrl slot=0 show config detail

## 看出slot=0缓存信息
hpacucli ctrl slot=0 show config detail | grep -i 'cache'

 

MegaRAID修改写缓存

## 强制在BBU损坏时使用Cache
/usr/local/sbin/MegaCli -LDSetProp CachedBadBBU -Lall -aALL

## 强制使用WriteBack写策略
/usr/local/sbin/MegaCli -LDSetProp WB -Lall -aALL 

 

HP RAID修改写缓存

## 关闭slot=0上物理磁盘缓存
hpssacli ctrl slot=0 modify drivewritecache=disable

## 开启slot=0上逻辑磁盘缓存
hpssacli ctrl slot=0 logicaldrive 2 modify caching=enable

## 开启slot=0上逻辑磁盘在BBU损坏时缓存
hpssacli ctrl slot=0 modify nobatterywritecache=enable

 

 

 

简易版的RAID检查脚本:

#!/bin/bash

##====================================================##
## 服务器信息 ##
server_vendor=`dmidecode -s system-manufacturer|sed '/^#/d'|awk '{print $1}'`
server_ip=`ip addr sh|grep -v 'global secondary'|grep inet|grep -v 169.254|grep -v inet6|grep -v '127.0.0.1'|grep -v '172.172.170.11'|grep -v '172.16.0.11'|awk '{print $2}'|awk -F'/' '{print $1}'|head -n 1`
docker_flag=`ps -ef|grep "sleep 99999"|grep -v grep|wc -l`
os_version=`cat /etc/issue |head   -1`

if [ "${docker_flag}" == "1" ]
then
	server_vendor="docker"
fi

raid_product_name=''
raid_slot_id=''
raid_cache_size=''
raid_level=''
raid_size=''
raid_status=''
raid_bbu_count=''
raid_bbu_status=''
raid_cache_policy=''
raid_logic_drive_count=''
raid_logic_drive_error=''
raid_physical_drive_error=''
raid_physical_drive_type=''
raid_physical_drive_size=''
raid_physical_drive_count=''
raid_predictive_failure_count=''
log_file='./raid_info.txt'



##====================================================##
## 安装包信息 ##
hpacucli_rpm_url="http://xxxx.com/hpacucli-9.40-12.0.x86_64.rpm"
hpacucli_rpm_name="hpacucli-9.40-12.0.x86_64.rpm"
lib_utils_rpm_url="http://xxxx.com/Lib_Utils-1.00-09.noarch.rpm"
lib_utils_rpm_name="Lib_Utils-1.00-09.noarch.rpm"
megacli_rpm_url="http://xxxx.com/MegaCli-8.02.21-1.noarch.rpm"
megacli_rpm_name="MegaCli-8.02.21-1.noarch.rpm"

##====================================================##
## 高亮输出信息 ##
function echo_info()
{
	message=$1
	echo -e "\033[;37;32m ${message} \033[0m"
}

function echo_error()
{
	message=$1
	echo -e "\033[;37;31m ${message} \033[0m"
}
##====================================================##
## 获取服务器ILO信息 ##
imm_idrac_mac="" 
imm_idrac_ip=""
function get_imm_info()
{
	if [[ "${server_vendor}" == "docker" ]]
	then
		echo_info "server is docker"
	elif [[ "${server_vendor}" == "HP" ]]
	then
		imm_idrac_mac=`timeout 3s ipmitool -I open lan print 2|grep "MAC Address" |awk '{print $4}'` 
		imm_idrac_ip=`timeout 3s ipmitool -I open lan print 2 |grep -w "IP Address " |awk -F : '{print $2}'|sed 's/^ *//'`
	elif [[ "${server_vendor}" == "LENOVO" ]]
	then
		imm_idrac_mac=`timeout 3s ipmitool -I open lan print 1|grep "MAC Address" |awk '{print $4}'` 
		imm_idrac_ip=`timeout 3s ipmitool -I open lan print 1 |grep -w "IP Address " |awk -F : '{print $2}'|sed 's/^ *//'`
	elif [[ "${server_vendor}" == "INSPUR" ]]
	then
		imm_idrac_mac=`timeout 3s ipmitool -I open lan print 8|grep "MAC Address" |awk '{print $4}'` 
		imm_idrac_ip=`timeout 3s ipmitool -I open lan print 8 |grep -w "IP Address " |awk -F : '{print $2}'|sed 's/^ *//'`
	else
		imm_idrac_mac=`timeout 3s ipmitool -I open lan print 1|grep "MAC Address" |awk '{print $4}'`
		imm_idrac_ip=`timeout 3s ipmitool -I open lan print 1 |grep -w "IP Address " |awk -F : '{print $2}'|sed 's/^ *//' `
	fi
}
get_imm_info
echo_info "ILO_MAC:${imm_idrac_mac}"
echo_info "ILO_IP:${imm_idrac_ip}"

##====================================================##
## 安装HP服务器使用的hpssacli ##

function install_hpssacli()
{
	rpm_count=`rpm -qa |grep -i 'hpacucli' |wc -l`
	if [ ${rpm_count} -gt 0 ]
	then
    	echo_info 'hpacucli has been installed' 
	else
		echo_info 'start to install hpacucli'
		/bin/rm -f "/tmp/${hpacucli_rpm_name}"
		wget -O "/tmp/${hpacucli_rpm_name}" "${hpacucli_rpm_url}"
	    rpm -ivh "/tmp/${hpacucli_rpm_name}" >/dev/null
	    echo_info 'end to install hpacucli'
	fi
}
##====================================================##
## 安装服务器使用的MegaCli ##
function install_MegaCli()
{
	rpm_count=`rpm -qa |grep 'Lib_Utils-' |wc -l`
	if [ ${rpm_count} -gt 0 ]
	then
	    echo_info 'Lib_Utils has been installed' 
	else
		echo_info 'start to install Lib_Utils'
		/bin/rm -f "/tmp/${lib_utils_rpm_name}"
		wget -O "/tmp/${lib_utils_rpm_name}" "${lib_utils_rpm_url}"
	    rpm -ivh "/tmp/${lib_utils_rpm_name}"
	    echo_info 'end to install Lib_Utils'
	fi

	rpm_count=`rpm -qa |grep 'MegaCli-' |wc -l`
	if [ ${rpm_count} -gt 0 ]
	then
	    echo_info 'MegaCli has been installed'
	else
		echo_info 'start to install Lib_Utils'
		/bin/rm -f "/tmp/${megacli_rpm_name}"
		wget -O "/tmp/${megacli_rpm_name}" "${megacli_rpm_url}"
	    rpm -ivh "/tmp/${megacli_rpm_name}"
	    echo_info 'end to install Lib_Utils'
	fi
}
##====================================================##
## 安装服务器RAID使用的包 ##
function install_raid_rpm()
{
	if [[ "${server_vendor}" == "docker" ]]
	then
		echo_info "server is docker"
	elif [[ "${server_vendor}" == "HP" ]]
	then
		install_hpssacli
	else
		install_MegaCli
	fi

}
##====================================================##
## 安装服务器RAID使用的包 ##

function get_hp_raid_info()
{
	raid_product_name='HP'
	raid_slot_id=`hpacucli ctrl all show status | grep 'Smart Array'|tail -n 1|awk '{ print $6 }'`
	raid_cache_size=`hpacucli ctrl all show config detail |grep 'Total Cache Size'|awk -F ':' '{print $2}'`
	raid_level=`hpacucli ctrl slot=${raid_slot_id} ld all show|grep -i 'raid' |awk -F ',' '{print $2}'`
	raid_size=`hpacucli ctrl slot=${raid_slot_id} ld all show|grep -i 'raid' |awk -F '(' '{print $2}'|awk -F ',' '{print $1}'`
	raid_status=`hpacucli ctrl all show config detail|grep 'Controller Status'|awk -F ':' '{print $2}'`
	raid_bbu_count=`hpacucli ctrl all show config detail|grep 'Capacitor Count'|awk -F ':' '{print $2}'`
	raid_bbu_status=`hpacucli ctrl all show config detail|grep 'Capacitor Status'|awk -F ':' '{print $2}'`
	raid_cache_radio=`hpacucli ctrl all show config detail|grep 'Cache Ratio'| sed 's/:/ is/g'`
	raid_cache_write_policy=`hpacucli ctrl all show config detail|grep 'No-Battery Write Cache' | sed 's/:/ is/g'`
	raid_cache_policy="${raid_cache_radio},${raid_cache_write_policy}"
	raid_logic_drive_count=`hpacucli ctrl all show status | grep 'Smart Array'|wc -l`
	raid_logic_drive_error=`hpacucli ctrl slot=${raid_slot_id} ld all show| grep 'logicaldrive' |grep -v 'OK' |wc -l`
	raid_physical_drive_error=`hpacucli ctrl slot=${raid_slot_id} physicaldrive all show| grep 'physicaldrive' |grep -v 'OK' |wc -l`
	raid_physical_drive_type=`hpacucli ctrl slot=${raid_slot_id} physicaldrive all show| grep 'physicaldrive' |tail -n 1|awk -F ',' '{print $2}'`
	raid_physical_drive_size=`hpacucli ctrl slot=${raid_slot_id} physicaldrive all show| grep 'physicaldrive' |tail -n 1|awk -F ',' '{print $3}'`
	raid_physical_drive_count=`hpacucli ctrl slot=${raid_slot_id} physicaldrive all show| grep 'physicaldrive' |wc -l`
	raid_predictive_failure_count=0
	raid_error_count=0
	if [[ "${raid_physical_drive_error}" != '0' ]]
	then
		raid_error_count=${raid_physical_drive_error}
	fi
	raid_warning_count=0

}

function get_normal_raid_info()
{
	raid_product_name=`/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL |egrep "Product Name" |awk -F ':' '{print $2}'`
	raid_cache_size=`/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL |egrep "Memory" | awk -F ':' '{print $2}'`
	raid_level=`/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL |grep 'RAID Level' |awk -F ':' '{print $2}'`
	raid_size=`/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL |egrep '^Size'|tail -n 1 |awk -F ':' '{print $2}'`
	raid_status=''
	raid_bbu_count=`/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL |egrep '^BBU'|wc -l`
	raid_bbu_status=`/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL |egrep '^BBU'|awk -F ':' '{print $2}'`
	raid_cache_policy=`/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL |grep 'Current Cache Policy' |tail -n 1 |awk -F ':' '{print $2}'`
	raid_logic_drive_count=`/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL |grep 'Target Id'|wc -l`
	raid_logic_drive_error=0
	raid_physical_drive_error=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep -i 'error' | grep -v '0' |wc -l`
	raid_physical_drive_type=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep 'Media Type' |tail -n 1 |awk -F ':' '{print $2}' |awk -F '[' '{print $1 }'`
	raid_physical_drive_size=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep 'Raw Size' |tail -n 1 |awk -F ':' '{print $2}' |awk -F '[' '{print $1 }'`
	raid_physical_drive_count=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep 'Raw Size' |wc -l`
	raid_span_depth=`/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL |egrep '^Span Depth'|tail -n 1 |awk -F ':' '{print $2}'|sed s/[[:space:]]//g`
	match_result=$(echo ${raid_level} |grep "Primary-1")
	
	raid_error_count=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep -i 'Firmware state' | grep 'Unconfigured(bad)' |wc -l`
	raid_warning_count=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep -i 'S.M.A.R.T alert' | grep -v ': No' |wc -l`
	
	raid_predictive_failure_count=`/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL |grep -i 'Predictive Failure Count' | grep -v ': 0' |wc -l`
	
	if [[ "${match_result}" != "" ]]
	then
		echo_info 'Primary-1'
		if [[ "${raid_span_depth}" == "1" ]]
		then 
			raid_level='RAID 1'
		else
			raid_level='RAID 10'
		fi
	fi
	match_result=$(echo ${raid_level} |grep "Primary-5")
	if [[ "${match_result}" != "" ]]
	then
		echo_info 'Primary-5'
		if [[ "${raid_span_depth}" == "1" ]]
		then 
			raid_level='RAID 5'
		else
			raid_level='RAID 50'
		fi
	fi
}

function get_raid_info()
{
	if [[ "${server_vendor}" == "docker" ]]
	then
		echo_info "server is docker"
	elif [[ "${server_vendor}" == "HP" ]]
	then
		get_hp_raid_info
	else
		get_normal_raid_info
	fi
}

function write_raid_info()
{
	echo "server_vendor:${server_vendor}" > "${log_file}"
	echo "server_ip:${server_ip}" >> "${log_file}"
	echo "os_version:${os_version}" >> "${log_file}"
	echo "imm_idrac_mac:${imm_idrac_mac}" >> "${log_file}"
	echo "imm_idrac_ip:${imm_idrac_ip}" >> "${log_file}"
	echo "raid_product_name:${raid_product_name}" >> "${log_file}"
	echo "raid_cache_size:${raid_cache_size}" >> "${log_file}"
	echo "raid_level:${raid_level}" >> "${log_file}"
	echo "raid_size:${raid_size}" >> "${log_file}"
	echo "raid_status:${raid_status}" >> "${log_file}"
	echo "raid_bbu_count:${raid_bbu_count}" >> "${log_file}"
	echo "raid_bbu_status:${raid_bbu_status}" >> "${log_file}"
	echo "raid_cache_policy:${raid_cache_policy}" >> "${log_file}"
	echo "raid_logic_drive_count:${raid_logic_drive_count}" >> "${log_file}"
	echo "raid_logic_drive_error:${raid_logic_drive_error}" >> "${log_file}"
	echo "raid_physical_drive_error:${raid_physical_drive_error}" >> "${log_file}"
	echo "raid_physical_drive_type:${raid_physical_drive_type}" >> "${log_file}"
	echo "raid_physical_drive_size:${raid_physical_drive_size}" >> "${log_file}"
	echo "raid_physical_drive_count:${raid_physical_drive_count}" >> "${log_file}"
	echo "raid_error_count:${raid_error_count}" >> "${log_file}"
	echo "raid_warning_count:${raid_warning_count}" >> "${log_file}"
	echo "raid_predictive_failure_count:${raid_predictive_failure_count}" >> "${log_file}"

}

echo_info "get imm rpm"
get_imm_info
echo_info "install rpm"
install_raid_rpm
echo_info "get raid info"
get_raid_info
echo_info "write raid info to log"
write_raid_info
echo_info "#======================Server Info=======================##"
cat "${log_file}"
echo_info "#========================================================##"

 

posted @ 2019-06-07 20:54  TeyGao  阅读(557)  评论(0编辑  收藏  举报