Dell服务器需要下载官网PERCCLI_MRXX5_7.1910.0_A12_VMware.tar.gz 工具

测试使用博通的storcli无法检测到阵列卡  BCM-vmware-storcli2_008.0008.0000.0010-01_23124082-package

[root@ESXI:/opt/lsi/storcli2] ./storcli2 show all
CLI Version = 008.0008.0000.0010 Jan 08, 2024
Operating system = VMkernel7.0.3
Status Code = 0
Status = Success
Description = None

Number of Controllers = 0
Host Name = ESXI.lan
Operating System  = VMkernel7.0.3
SL8 Library Version = 08.0807.0000

cd /opt/lsi/  

./perccli64 show all

[root@ESXI:/opt/lsi/perccli64] ./perccli64 show all
CLI Version = 007.1910.0000.0000 Oct 08, 2021
Operating system = VMkernel 7.0.3
Status Code = 0
Status = Success
Description = None

Number of Controllers = 1
Host Name = ESXI.lan
Operating System  = VMkernel 7.0.3
StoreLib IT Version = 07.2000.0200.0200
StoreLib IR3 Version = 16.14-0

System Overview :
===============

------------------------------------------------------------------------
Ctl Model        Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
------------------------------------------------------------------------
  0 PERCH730Mini     8   4   1     0   1     0 Opt On  3  N      0 Opt
------------------------------------------------------------------------

Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
Chrg=Charging | MsngCbl=Cable Failure

ASO :
===

----
Ctl
----
  0
----

Ctl=Controller Index|Cl=Cluster|MD=Max Disks|WC=Wide Cache|SS=Safe Store|FP=Fast Path
Re=Recovery|CR=CacheCade(Read)|RF=Reduced Feature Set|CO=Cache Offload
CW=CacheCade(Read/Write)|X=Not Available/Not Installed|U=Unlimited|T=Trial
|HA=High Availability |SSHA=Single server High Availability

 

[root@ESXI:/vmfs/volumes/621641d5-dbe627f4-8462-f48e38c0a278] esxcli software component apply -d /vmfs/volumes/621641d5-dbe627f
4-8462-f48e38c0a278/VMWare-perccli64_007.1910.zip
Installation Result
   Components Installed: BCM-vmware-perccli64_007.1910.0000.0000-01
   Components Removed:
   Components Skipped:
   Message: Operation finished successfully.
   Reboot Required: false
[root@ESXI:/vmfs/volumes/621641d5-dbe627f4-8462-f48e38c0a278] esxcli software component apply -d /vmfs/volumes/621641d5-dbe627f
4-8462-f48e38c0a278/VMWare-ESXi7.0-Provider.zip
 [InstallationError]
 ('BCM_bootbank_lsiprovider_700.00.V0.82-0001', 'Could not find a trusted signer: unable to get local issuer certificate')
      cause = ('BCM_bootbank_lsiprovider_700.00.V0.82-0001', 'Could not find a trusted signer: unable to get local issuer certificate')
       vibs = ['BCM_bootbank_lsiprovider_700.00.V0.82-0001']
 Please refer to the log file for more details.
[root@ESXI:/vmfs/volumes/621641d5-dbe627f4-8462-f48e38c0a278] esxcli software component apply -d /vmfs/volumes/621641d5-dbe627f
4-8462-f48e38c0a278/VMWare-ESXi7.0-Provider.zip -no^C
[root@ESXI:/vmfs/volumes/621641d5-dbe627f4-8462-f48e38c0a278] esxcli software component apply -d /vmfs/volumes/621641d5-dbe627f
4-8462-f48e38c0a278/VMWare-ESXi7.0-Provider.zip --no-sig-check

Installation Result
   Components Installed: BCM-lsiprovider_700.00.V0.82-0001
   Components Removed:
   Components Skipped:
   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
   Reboot Required: true

卸载安装的组件

 esxcli software component list

  esxcli software component remove -n BCM-vmware-storcli2

posted on 2024-04-22 19:54  时光2020  阅读(320)  评论(0编辑  收藏  举报