数据库误删了数据再也不用跑路了,

USE master GO --创建数据库 CREATE DATABASE test GO

USE [test] GO

--创建表 CREATE TABLE [dbo].[aa](     [id] [int] IDENTITY(1,1) NOT NULL,     [NAME] [nvarchar](200) NULL ) ON [PRIMARY] GO

--插入测试数据 INSERT [dbo].[aa]         ( [NAME] ) SELECT '你好' GO

 

--删除数据 Delete from aa Go

 

--验证数据是否已经删除 Select * from aa Go

上面是创建数据库,表,添加数据,删除数据

 

下面写存储过程;

--------------------------开始存储过程-----------------------------------------

CREATE PROCEDURE Recover_Deleted_Data_Proc  @Database_Name NVARCHAR(MAX) ,  @SchemaName_n_TableName NVARCHAR(MAX) ,  @Date_From DATETIME = '1900/01/01' ,  @Date_To DATETIME = '9999/12/31' AS  DECLARE @RowLogContents VARBINARY(8000)  DECLARE @TransactionID NVARCHAR(MAX)  DECLARE @AllocUnitID BIGINT  DECLARE @AllocUnitName NVARCHAR(MAX)  DECLARE @SQL NVARCHAR(MAX)  DECLARE @Compatibility_Level INT      SELECT @Compatibility_Level = dtb.compatibility_level  FROM master.sys.databases AS dtb  WHERE dtb.name = @Database_Name    IF ISNULL(@Compatibility_Level, 0) <= 80  BEGIN  RAISERROR('The compatibility level should be equal to or greater SQL SERVER 2005 (90)',16,1)  RETURN  END    IF ( SELECT COUNT(*)  FROM INFORMATION_SCHEMA.TABLES  WHERE [TABLE_SCHEMA] + '.' + [TABLE_NAME] = @SchemaName_n_TableName  ) = 0  BEGIN  RAISERROR('Could not found the table in the defined database',16,1)  RETURN  END    DECLARE @bitTable TABLE  (  [ID] INT ,  [Bitvalue] INT  ) --Create table to set the bit position of one byte.    INSERT INTO @bitTable  SELECT 0 ,  2  UNION ALL  SELECT 1 ,  2  UNION ALL  SELECT 2 ,  4  UNION ALL  SELECT 3 ,  8  UNION ALL  SELECT 4 ,  16  UNION ALL  SELECT 5 ,  32  UNION ALL  SELECT 6 ,  64  UNION ALL  SELECT 7 ,  128   --Create table to collect the row data.  DECLARE @DeletedRecords TABLE  (  [Row ID] INT IDENTITY(1, 1) ,  [RowLogContents] VARBINARY(8000) ,  [AllocUnitID] BIGINT ,  [Transaction ID] NVARCHAR(MAX) ,  [FixedLengthData] SMALLINT ,  [TotalNoOfCols] SMALLINT ,  [NullBitMapLength] SMALLINT ,  [NullBytes] VARBINARY(8000) ,  [TotalNoofVarCols] SMALLINT ,  [ColumnOffsetArray] VARBINARY(8000) ,  [VarColumnStart] SMALLINT ,  [Slot ID] INT ,  [NullBitMap] VARCHAR(MAX)  ) --Create a common table expression to get all the row data plus how many bytes we have for each row. ;  WITH RowData  AS ( SELECT [RowLog Contents 0] AS [RowLogContents] ,  [AllocUnitID] AS [AllocUnitID] ,  [Transaction ID] AS [Transaction ID]   --[Fixed Length Data] = Substring (RowLog content 0, Status Bit A+ Status Bit B + 1,2 bytes)  ,  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) AS [FixedLengthData] --@FixedLengthData   -- [TotalnoOfCols] = Substring (RowLog content 0, [Fixed Length Data] + 1,2 bytes)  ,  CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) AS [TotalNoOfCols]   --[NullBitMapLength]=ceiling([Total No of Columns] /8.0)  ,  CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0)) AS [NullBitMapLength]   --[Null Bytes] = Substring (RowLog content 0, Status Bit A+ Status Bit B + [Fixed Length Data] +1, [NullBitMapLength] )  ,  SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 3,  CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0))) AS [NullBytes]   --[TotalNoofVarCols] = Substring (RowLog content 0, Status Bit A+ Status Bit B + [Fixed Length Data] +1, [Null Bitmap length] + 2 )  ,  ( CASE WHEN SUBSTRING([RowLog Contents 0], 1, 1) IN (  0x10, 0x30, 0x70 )  THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 3  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0)), 2))))  ELSE NULL  END ) AS [TotalNoofVarCols]   --[ColumnOffsetArray]= Substring (RowLog content 0, Status Bit A+ Status Bit B + [Fixed Length Data] +1, [Null Bitmap length] + 2 , [TotalNoofVarCols]*2 )  ,  ( CASE WHEN SUBSTRING([RowLog Contents 0], 1, 1) IN (  0x10, 0x30, 0x70 )  THEN SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 3  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0))  + 2,  ( CASE WHEN SUBSTRING([RowLog Contents 0],  1, 1) IN ( 0x10,  0x30, 0x70 )  THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 3  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0)), 2))))  ELSE NULL  END ) * 2)  ELSE NULL  END ) AS [ColumnOffsetArray]   -- Variable column Start = Status Bit A+ Status Bit B + [Fixed Length Data] + [Null Bitmap length] + 2+([TotalNoofVarCols]*2)  ,  CASE WHEN SUBSTRING([RowLog Contents 0], 1, 1) IN (  0x10, 0x30, 0x70 )  THEN ( CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 4  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0))  + ( ( CASE WHEN SUBSTRING([RowLog Contents 0],  1, 1) IN ( 0x10,  0x30, 0x70 )  THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 3  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],  2 + 1, 2)))) + 1,  2)))) / 8.0)), 2))))  ELSE NULL  END ) * 2 ) )  ELSE NULL  END AS [VarColumnStart] ,  [Slot ID]  FROM sys.fn_dblog(NULL, NULL)  WHERE AllocUnitId IN (  SELECT [Allocation_unit_id]  FROM sys.allocation_units allocunits  INNER JOIN sys.partitions partitions ON ( allocunits.type IN (  1, 3 )  AND partitions.hobt_id = allocunits.container_id  )  OR ( allocunits.type = 2  AND partitions.partition_id = allocunits.container_id  )  WHERE object_id = OBJECT_ID(''  + @SchemaName_n_TableName  + '') )  AND Context IN ( 'LCX_MARK_AS_GHOST', 'LCX_HEAP' )  AND Operation IN ( 'LOP_DELETE_ROWS' )  AND SUBSTRING([RowLog Contents 0], 1, 1) IN ( 0x10,  0x30, 0x70 )   /*Use this subquery to filter the date*/  AND [TRANSACTION ID] IN (  SELECT DISTINCT  [TRANSACTION ID]  FROM sys.fn_dblog(NULL, NULL)  WHERE Context IN ( 'LCX_NULL' )  AND Operation IN ( 'LOP_BEGIN_XACT' )  AND [Transaction Name] IN ( 'DELETE',  'user_transaction' )  AND CONVERT(NVARCHAR(11), [Begin Time]) BETWEEN @Date_From  AND  @Date_To )  ),   --Use this technique to repeate the row till the no of bytes of the row.  N1 ( n )  AS ( SELECT 1  UNION ALL  SELECT 1  ),  N2 ( n )  AS ( SELECT 1  FROM N1 AS X ,  N1 AS Y  ),  N3 ( n )  AS ( SELECT 1  FROM N2 AS X ,  N2 AS Y  ),  N4 ( n )  AS ( SELECT ROW_NUMBER() OVER ( ORDER BY X.n )  FROM N3 AS X ,  N3 AS Y  )  INSERT INTO @DeletedRecords  SELECT RowLogContents ,  [AllocUnitID] ,  [Transaction ID] ,  [FixedLengthData] ,  [TotalNoOfCols] ,  [NullBitMapLength] ,  [NullBytes] ,  [TotalNoofVarCols] ,  [ColumnOffsetArray] ,  [VarColumnStart] ,  [Slot ID]  ---Get the Null value against each column (1 means null zero means not null)  ,  [NullBitMap] = ( REPLACE(STUFF(( SELECT  ','  + ( CASE  WHEN [ID] = 0  THEN CONVERT(NVARCHAR(1), ( SUBSTRING(NullBytes,  n, 1) % 2 ))  ELSE CONVERT(NVARCHAR(1), ( ( SUBSTRING(NullBytes,  n, 1)  / [Bitvalue] )  % 2 ))  END ) --as [nullBitMap]  FROM N4 AS Nums  JOIN RowData AS C ON n <= NullBitMapLength  CROSS JOIN @bitTable  WHERE  C.[RowLogContents] = D.[RowLogContents]  ORDER BY [RowLogContents] ,  n ASC  FOR  XML PATH('')  ), 1, 1, ''), ',', '') )  FROM RowData D    IF ( SELECT COUNT(*)  FROM @DeletedRecords  ) = 0  BEGIN  RAISERROR('There is no data in the log as per the search criteria',16,1)  RETURN  END    DECLARE @ColumnNameAndData TABLE  (  [Row ID] INT ,  [Rowlogcontents] VARBINARY(MAX) ,  [NAME] SYSNAME ,  [nullbit] SMALLINT ,  [leaf_offset] SMALLINT ,  [length] SMALLINT ,  [system_type_id] TINYINT ,  [bitpos] TINYINT ,  [xprec] TINYINT ,  [xscale] TINYINT ,  [is_null] INT ,  [Column value Size] INT ,  [Column Length] INT ,  [hex_Value] VARBINARY(MAX) ,  [Slot ID] INT ,  [Update] INT  )   --Create common table expression and join it with the rowdata table -- to get each column details /*This part is for variable data columns*/ --@RowLogContents, --(col.columnOffValue - col.columnLength) + 1, --col.columnLength --)  INSERT INTO @ColumnNameAndData  SELECT [Row ID] ,  Rowlogcontents ,  NAME ,  cols.leaf_null_bit AS nullbit ,  leaf_offset ,  ISNULL(syscolumns.length, cols.max_length) AS [length] ,  cols.system_type_id ,  cols.leaf_bit_position AS bitpos ,  ISNULL(syscolumns.xprec, cols.precision) AS xprec ,  ISNULL(syscolumns.xscale, cols.scale) AS xscale ,  SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) AS is_null ,  ( CASE WHEN leaf_offset < 1  AND SUBSTRING([nullBitMap], cols.leaf_null_bit,  1) = 0  THEN ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - POWER(2, 15)  ELSE CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  END )  END ) AS [Column value Size] ,  ( CASE WHEN leaf_offset < 1  AND SUBSTRING([nullBitMap], cols.leaf_null_bit,  1) = 0  THEN ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) < 30000  THEN ( CASE WHEN [System_type_id] IN (  35, 34, 99 ) THEN 16  ELSE 24  END )  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) > 30000  THEN ( CASE WHEN [System_type_id] IN (  35, 34, 99 ) THEN 16  ELSE 24  END ) --24  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) < 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) < 30000  THEN ( CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) )  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) < 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) > 30000  THEN POWER(2, 15)  + CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart])  END )  END ) AS [Column Length] ,  ( CASE WHEN SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) = 1  THEN NULL  ELSE SUBSTRING(Rowlogcontents,  ( ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - POWER(2, 15)  ELSE CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  END )  - ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) < 30000  THEN ( CASE  WHEN [System_type_id] IN (  35, 34, 99 )  THEN 16  ELSE 24  END ) --24  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) > 30000  THEN ( CASE  WHEN [System_type_id] IN (  35, 34, 99 )  THEN 16  ELSE 24  END ) --24  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) < 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) < 30000  THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart])  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) < 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) > 30000  THEN POWER(2, 15)  + CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart])  END ) ) + 1,  ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) < 30000  THEN ( CASE WHEN [System_type_id] IN (  35, 34, 99 )  THEN 16  ELSE 24  END ) --24  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) > 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) > 30000  THEN ( CASE WHEN [System_type_id] IN (  35, 34, 99 )  THEN 16  ELSE 24  END ) --24  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) < 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) < 30000  THEN ABS(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]))  WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2)))) < 30000  AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart]) > 30000  THEN POWER(2, 15)  + CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * leaf_offset  * -1 ) - 1, 2))))  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],  ( 2  * ( ( leaf_offset  * -1 ) - 1 ) )  - 1, 2)))), 0),  [varColumnStart])  END ))  END ) AS hex_Value ,  [Slot ID] ,  0  FROM @DeletedRecords A  INNER JOIN sys.allocation_units allocunits ON A.[AllocUnitId] = allocunits.[Allocation_Unit_Id]  INNER JOIN sys.partitions partitions ON ( allocunits.type IN (  1, 3 )  AND partitions.hobt_id = allocunits.container_id  )  OR ( allocunits.type = 2  AND partitions.partition_id = allocunits.container_id  )  INNER JOIN sys.system_internals_partition_columns cols ON cols.partition_id = partitions.partition_id  LEFT OUTER JOIN syscolumns ON syscolumns.id = partitions.object_id  AND syscolumns.colid = cols.partition_column_id  WHERE leaf_offset < 0  UNION /*This part is for fixed data columns*/  SELECT [Row ID] ,  Rowlogcontents ,  NAME ,  cols.leaf_null_bit AS nullbit ,  leaf_offset ,  ISNULL(syscolumns.length, cols.max_length) AS [length] ,  cols.system_type_id ,  cols.leaf_bit_position AS bitpos ,  ISNULL(syscolumns.xprec, cols.precision) AS xprec ,  ISNULL(syscolumns.xscale, cols.scale) AS xscale ,  SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) AS is_null ,  ( SELECT TOP 1  ISNULL(SUM(CASE WHEN C.leaf_offset > 1  THEN max_length  ELSE 0  END), 0)  FROM sys.system_internals_partition_columns C  WHERE cols.partition_id = C.partition_id  AND C.leaf_null_bit < cols.leaf_null_bit  ) + 5 AS [Column value Size] ,  syscolumns.length AS [Column Length] ,  CASE WHEN SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) = 1  THEN NULL  ELSE SUBSTRING(Rowlogcontents,  ( SELECT TOP 1  ISNULL(SUM(CASE  WHEN C.leaf_offset > 1  AND C.leaf_bit_position = 0  THEN max_length  ELSE 0  END), 0)  FROM sys.system_internals_partition_columns C  WHERE cols.partition_id = C.partition_id  AND C.leaf_null_bit < cols.leaf_null_bit  ) + 5, syscolumns.length)  END AS hex_Value ,  [Slot ID] ,  0  FROM @DeletedRecords A  INNER JOIN sys.allocation_units allocunits ON A.[AllocUnitId] = allocunits.[Allocation_Unit_Id]  INNER JOIN sys.partitions partitions ON ( allocunits.type IN (  1, 3 )  AND partitions.hobt_id = allocunits.container_id  )  OR ( allocunits.type = 2  AND partitions.partition_id = allocunits.container_id  )  INNER JOIN sys.system_internals_partition_columns cols ON cols.partition_id = partitions.partition_id  LEFT OUTER JOIN syscolumns ON syscolumns.id = partitions.object_id  AND syscolumns.colid = cols.partition_column_id  WHERE leaf_offset > 0  ORDER BY nullbit    DECLARE @BitColumnByte AS INT  SELECT @BitColumnByte = CONVERT(INT, CEILING(COUNT(*) / 8.0))  FROM @ColumnNameAndData  WHERE [System_Type_id] = 104;  WITH N1 ( n )  AS ( SELECT 1  UNION ALL  SELECT 1  ),  N2 ( n )  AS ( SELECT 1  FROM N1 AS X ,  N1 AS Y  ),  N3 ( n )  AS ( SELECT 1  FROM N2 AS X ,  N2 AS Y  ),  N4 ( n )  AS ( SELECT ROW_NUMBER() OVER ( ORDER BY X.n )  FROM N3 AS X ,  N3 AS Y  ),  CTE  AS ( SELECT RowLogContents ,  [nullbit] ,  [BitMap] = CONVERT(VARBINARY(1), CONVERT(INT, SUBSTRING(( REPLACE(STUFF(( SELECT  ','  + ( CASE  WHEN [ID] = 0  THEN CONVERT(NVARCHAR(1), ( SUBSTRING(hex_Value,  n, 1) % 2 ))  ELSE CONVERT(NVARCHAR(1), ( ( SUBSTRING(hex_Value,  n, 1)  / [Bitvalue] )  % 2 ))  END ) --as [nullBitMap]  FROM  N4 AS Nums  JOIN @ColumnNameAndData  AS C ON n <= @BitColumnByte  AND [System_Type_id] = 104  AND bitpos = 0  CROSS JOIN @bitTable  WHERE  C.[RowLogContents] = D.[RowLogContents]  ORDER BY [RowLogContents] ,  n ASC  FOR  XML  PATH('')  ), 1, 1, ''),  ',', '') ),  bitpos + 1, 1)))  FROM @ColumnNameAndData D  WHERE [System_Type_id] = 104  )  UPDATE A  SET [hex_Value] = [BitMap]  FROM @ColumnNameAndData A  INNER JOIN CTE B ON A.[RowLogContents] = B.[RowLogContents]  AND A.[nullbit] = B.[nullbit]     /**************Check for BLOB DATA TYPES******************************/  DECLARE @Fileid INT  DECLARE @Pageid INT  DECLARE @Slotid INT  DECLARE @CurrentLSN INT  DECLARE @LinkID INT  DECLARE @Context VARCHAR(50)  DECLARE @ConsolidatedPageID VARCHAR(MAX)  DECLARE @LCX_TEXT_MIX VARBINARY(MAX)    DECLARE @temppagedata TABLE  (  [ParentObject] SYSNAME ,  [Object] SYSNAME ,  [Field] SYSNAME ,  [Value] SYSNAME  )    DECLARE @pagedata TABLE  (  [Page ID] SYSNAME ,  [File IDS] INT ,  [Page IDS] INT ,  [AllocUnitId] BIGINT ,  [ParentObject] SYSNAME ,  [Object] SYSNAME ,  [Field] SYSNAME ,  [Value] SYSNAME  )    DECLARE @ModifiedRawData TABLE  (  [ID] INT IDENTITY(1, 1) ,  [PAGE ID] VARCHAR(MAX) ,  [FILE IDS] INT ,  [PAGE IDS] INT ,  [Slot ID] INT ,  [AllocUnitId] BIGINT ,  [RowLog Contents 0_var] VARCHAR(MAX) ,  [RowLog Length] VARCHAR(50) ,  [RowLog Len] INT ,  [RowLog Contents 0] VARBINARY(MAX) ,  [Link ID] INT DEFAULT ( 0 ) ,  [Update] INT  )    DECLARE Page_Data_Cursor CURSOR  FOR  /*We need to filter LOP_MODIFY_ROW,LOP_MODIFY_COLUMNS from log for deleted records of BLOB data type& Get its Slot No, Page ID & AllocUnit ID*/  SELECT LTRIM(RTRIM(REPLACE([Description], 'Deallocated', ''))) AS [PAGE ID] ,  [Slot ID] ,  [AllocUnitId] ,  NULL AS [RowLog Contents 0] ,  NULL AS [RowLog Contents 0] ,  Context  FROM sys.fn_dblog(NULL, NULL)  WHERE AllocUnitId IN (  SELECT [Allocation_unit_id]  FROM sys.allocation_units allocunits  INNER JOIN sys.partitions partitions ON ( allocunits.type IN (  1, 3 )  AND partitions.hobt_id = allocunits.container_id  )  OR ( allocunits.type = 2  AND partitions.partition_id = allocunits.container_id  )  WHERE object_id = OBJECT_ID('' + @SchemaName_n_TableName  + '') )  AND Operation IN ( 'LOP_MODIFY_ROW' )  AND [Context] IN ( 'LCX_PFS' )  AND Description LIKE '%Deallocated%'  /*Use this subquery to filter the date*/  AND [TRANSACTION ID] IN (  SELECT DISTINCT  [TRANSACTION ID]  FROM sys.fn_dblog(NULL, NULL)  WHERE Context IN ( 'LCX_NULL' )  AND Operation IN ( 'LOP_BEGIN_XACT' )  AND [Transaction Name] = 'DELETE'  AND CONVERT(NVARCHAR(11), [Begin Time]) BETWEEN @Date_From  AND  @Date_To )  GROUP BY [Description] ,  [Slot ID] ,  [AllocUnitId] ,  Context  UNION  SELECT [PAGE ID] ,  [Slot ID] ,  [AllocUnitId] ,  SUBSTRING([RowLog Contents 0], 15,  LEN([RowLog Contents 0])) AS [RowLog Contents 0] ,  CONVERT(INT, SUBSTRING([RowLog Contents 0], 7, 2)) ,  Context --,CAST(RIGHT([Current LSN],4) AS INT) AS [Current LSN]  FROM sys.fn_dblog(NULL, NULL)  WHERE AllocUnitId IN (  SELECT [Allocation_unit_id]  FROM sys.allocation_units allocunits  INNER JOIN sys.partitions partitions ON ( allocunits.type IN (  1, 3 )  AND partitions.hobt_id = allocunits.container_id  )  OR ( allocunits.type = 2  AND partitions.partition_id = allocunits.container_id  )  WHERE object_id = OBJECT_ID('' + @SchemaName_n_TableName  + '') )  AND Context IN ( 'LCX_TEXT_MIX' )  AND Operation IN ( 'LOP_DELETE_ROWS' )  /*Use this subquery to filter the date*/  AND [TRANSACTION ID] IN (  SELECT DISTINCT  [TRANSACTION ID]  FROM sys.fn_dblog(NULL, NULL)  WHERE Context IN ( 'LCX_NULL' )  AND Operation IN ( 'LOP_BEGIN_XACT' )  AND [Transaction Name] = 'DELETE'  AND CONVERT(NVARCHAR(11), [Begin Time]) BETWEEN @Date_From  AND  @Date_To )    /****************************************/    OPEN Page_Data_Cursor    FETCH NEXT FROM Page_Data_Cursor INTO @ConsolidatedPageID, @Slotid,  @AllocUnitID, @LCX_TEXT_MIX, @LinkID, @Context    WHILE @@FETCH_STATUS = 0  BEGIN  DECLARE @hex_pageid AS VARCHAR(MAX)  /*Page ID contains File Number and page number It looks like 0001:00000130.  In this example 0001 is file Number & 00000130 is Page Number & These numbers are in Hex format*/  SET @Fileid = SUBSTRING(@ConsolidatedPageID, 0,  CHARINDEX(':', @ConsolidatedPageID)) -- Seperate File ID from Page ID    SET @hex_pageid = '0x' + SUBSTRING(@ConsolidatedPageID,  CHARINDEX(':',  @ConsolidatedPageID)  + 1, LEN(@ConsolidatedPageID)) ---Seperate the page ID  SELECT @Pageid = CONVERT(INT, CAST('' AS XML).value('xs:hexBinary(substring(sql:variable("@hex_pageid"),sql:column("t.pos")) )',  'varbinary(max)')) -- Convert Page ID from hex to integer  FROM ( SELECT CASE SUBSTRING(@hex_pageid, 1, 2)  WHEN '0x' THEN 3  ELSE 0  END  ) AS t ( pos )    IF @Context = 'LCX_PFS'  BEGIN  DELETE @temppagedata  INSERT INTO @temppagedata  EXEC  ( 'DBCC PAGE(' + @DataBase_Name + ', '  + @fileid + ', ' + @pageid  + ', 1) with tableresults,no_infomsgs;'  );  INSERT INTO @pagedata  SELECT @ConsolidatedPageID ,  @fileid ,  @pageid ,  @AllocUnitID ,  [ParentObject] ,  [Object] ,  [Field] ,  [Value]  FROM @temppagedata  END  ELSE  IF @Context = 'LCX_TEXT_MIX'  BEGIN  INSERT INTO @ModifiedRawData  SELECT @ConsolidatedPageID ,  @fileid ,  @pageid ,  @Slotid ,  @AllocUnitID ,  NULL ,  0 ,  CONVERT(INT, CONVERT(VARBINARY, REVERSE(SUBSTRING(@LCX_TEXT_MIX,  11, 2)))) ,  @LCX_TEXT_MIX ,  @LinkID ,  0  END  FETCH NEXT FROM Page_Data_Cursor INTO @ConsolidatedPageID, @Slotid,  @AllocUnitID, @LCX_TEXT_MIX, @LinkID, @Context  END    CLOSE Page_Data_Cursor  DEALLOCATE Page_Data_Cursor    DECLARE @Newhexstring VARCHAR(MAX);    --The data is in multiple rows in the page, so we need to convert it into one row as a single hex value.  --This hex value is in string format  INSERT INTO @ModifiedRawData  ( [PAGE ID] ,  [FILE IDS] ,  [PAGE IDS] ,  [Slot ID] ,  [AllocUnitId] ,  [RowLog Contents 0_var] ,  [RowLog Length]  )  SELECT [Page ID] ,  [FILE IDS] ,  [PAGE IDS] ,  SUBSTRING([ParentObject],  CHARINDEX('Slot', [ParentObject]) + 4,  ( CHARINDEX('Offset', [ParentObject])  - ( CHARINDEX('Slot', [ParentObject]) + 4 ) )  - 2) AS [Slot ID] ,  [AllocUnitId] ,  SUBSTRING(( SELECT REPLACE(STUFF(( SELECT  REPLACE(SUBSTRING([Value],  CHARINDEX(':',  [Value]) + 1,  CHARINDEX('†',  [Value])  - CHARINDEX(':',  [Value])), '†',  '')  FROM @pagedata C  WHERE B.[Page ID] = C.[Page ID]  AND SUBSTRING(B.[ParentObject],  CHARINDEX('Slot',  B.[ParentObject])  + 4,  ( CHARINDEX('Offset',  B.[ParentObject])  - ( CHARINDEX('Slot',  B.[ParentObject])  + 4 ) )) = SUBSTRING(C.[ParentObject],  CHARINDEX('Slot',  C.[ParentObject])  + 4,  ( CHARINDEX('Offset',  C.[ParentObject])  - ( CHARINDEX('Slot',  C.[ParentObject])  + 4 ) ))  AND [Object] LIKE '%Memory Dump%'  ORDER BY '0x'  + LEFT([Value],  CHARINDEX(':',  [Value]) - 1)  FOR  XML PATH('')  ), 1, 1, ''), ' ', '')  ), 1, 20000) AS [Value] ,  SUBSTRING(( SELECT '0x'  + REPLACE(STUFF(( SELECT  REPLACE(SUBSTRING([Value],  CHARINDEX(':',  [Value]) + 1,  CHARINDEX('†',  [Value])  - CHARINDEX(':',  [Value])), '†',  '')  FROM  @pagedata C  WHERE  B.[Page ID] = C.[Page ID]  AND SUBSTRING(B.[ParentObject],  CHARINDEX('Slot',  B.[ParentObject])  + 4,  ( CHARINDEX('Offset',  B.[ParentObject])  - ( CHARINDEX('Slot',  B.[ParentObject])  + 4 ) )) = SUBSTRING(C.[ParentObject],  CHARINDEX('Slot',  C.[ParentObject])  + 4,  ( CHARINDEX('Offset',  C.[ParentObject])  - ( CHARINDEX('Slot',  C.[ParentObject])  + 4 ) ))  AND [Object] LIKE '%Memory Dump%'  ORDER BY '0x'  + LEFT([Value],  CHARINDEX(':',  [Value]) - 1)  FOR  XML PATH('')  ), 1, 1, ''), ' ', '')  ), 7, 4) AS [Length]  FROM @pagedata B  WHERE [Object] LIKE '%Memory Dump%'  GROUP BY [Page ID] ,  [FILE IDS] ,  [PAGE IDS] ,  [ParentObject] ,  [AllocUnitId]--,[Current LSN]  ORDER BY [Slot ID]    UPDATE @ModifiedRawData  SET [RowLog Len] = CONVERT(VARBINARY(8000), REVERSE(CAST('' AS XML).value('xs:hexBinary(substring(sql:column("[RowLog Length]"),0))',  'varbinary(Max)')))  FROM @ModifiedRawData  WHERE [LINK ID] = 0    UPDATE @ModifiedRawData  SET [RowLog Contents 0] = CAST('' AS XML).value('xs:hexBinary(substring(sql:column("[RowLog Contents 0_var]"),0))',  'varbinary(Max)')  FROM @ModifiedRawData  WHERE [LINK ID] = 0    UPDATE B  SET B.[RowLog Contents 0] = ( CASE WHEN A.[RowLog Contents 0] IS NOT NULL  AND C.[RowLog Contents 0] IS NOT NULL  THEN A.[RowLog Contents 0]  + C.[RowLog Contents 0]  WHEN A.[RowLog Contents 0] IS NULL  AND C.[RowLog Contents 0] IS NOT NULL  THEN C.[RowLog Contents 0]  WHEN A.[RowLog Contents 0] IS NOT NULL  AND C.[RowLog Contents 0] IS NULL  THEN A.[RowLog Contents 0]  END ) ,  B.[Update] = ISNULL(B.[Update], 0) + 1  FROM @ModifiedRawData B  LEFT JOIN @ModifiedRawData A ON A.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  15 + 14, 2))))  AND A.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  19 + 14, 2))))  AND A.[Link ID] = B.[Link ID]  LEFT JOIN @ModifiedRawData C ON C.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  27 + 14, 2))))  AND C.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  31 + 14, 2))))  AND C.[Link ID] = B.[Link ID]  WHERE ( A.[RowLog Contents 0] IS NOT NULL  OR C.[RowLog Contents 0] IS NOT NULL  )      UPDATE B  SET B.[RowLog Contents 0] = ( CASE WHEN A.[RowLog Contents 0] IS NOT NULL  AND C.[RowLog Contents 0] IS NOT NULL  THEN A.[RowLog Contents 0]  + C.[RowLog Contents 0]  WHEN A.[RowLog Contents 0] IS NULL  AND C.[RowLog Contents 0] IS NOT NULL  THEN C.[RowLog Contents 0]  WHEN A.[RowLog Contents 0] IS NOT NULL  AND C.[RowLog Contents 0] IS NULL  THEN A.[RowLog Contents 0]  END )  --,B.[Update]=ISNULL(B.[Update],0)+1  FROM @ModifiedRawData B  LEFT JOIN @ModifiedRawData A ON A.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  15 + 14, 2))))  AND A.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  19 + 14, 2))))  AND A.[Link ID] <> B.[Link ID]  AND B.[Update] = 0  LEFT JOIN @ModifiedRawData C ON C.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  27 + 14, 2))))  AND C.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],  31 + 14, 2))))  AND C.[Link ID] <> B.[Link ID]  AND B.[Update] = 0  WHERE ( A.[RowLog Contents 0] IS NOT NULL  OR C.[RowLog Contents 0] IS NOT NULL  )    UPDATE @ModifiedRawData  SET [RowLog Contents 0] = ( CASE WHEN [RowLog Len] >= 8000  THEN SUBSTRING([RowLog Contents 0],  15, [RowLog Len])  WHEN [RowLog Len] < 8000  THEN SUBSTRING([RowLog Contents 0],  15 + 6,  CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([RowLog Contents 0],  15, 6)))))  END )  FROM @ModifiedRawData  WHERE [LINK ID] = 0    UPDATE @ColumnNameAndData  SET [hex_Value] = [RowLog Contents 0]  --,A.[Update]=A.[Update]+1  FROM @ColumnNameAndData A  INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],  17, 4)))) = [PAGE IDS]  AND CONVERT(INT, SUBSTRING([hex_value],  9, 2)) = B.[Link ID]  WHERE [System_Type_Id] IN ( 99, 167, 175, 231, 239, 241, 165, 98 )  AND [Link ID] <> 0    UPDATE @ColumnNameAndData  SET [hex_Value] = ( CASE WHEN B.[RowLog Contents 0] IS NOT NULL  AND C.[RowLog Contents 0] IS NOT NULL  THEN B.[RowLog Contents 0]  + C.[RowLog Contents 0]  WHEN B.[RowLog Contents 0] IS NULL  AND C.[RowLog Contents 0] IS NOT NULL  THEN C.[RowLog Contents 0]  WHEN B.[RowLog Contents 0] IS NOT NULL  AND C.[RowLog Contents 0] IS NULL  THEN B.[RowLog Contents 0]  END )  --,A.[Update]=A.[Update]+1  FROM @ColumnNameAndData A  LEFT JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],  5, 4)))) = B.[PAGE IDS]  AND B.[Link ID] = 0  LEFT JOIN @ModifiedRawData C ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],  17, 4)))) = C.[PAGE IDS]  AND C.[Link ID] = 0  WHERE [System_Type_Id] IN ( 99, 167, 175, 231, 239, 241, 165, 98 )  AND ( B.[RowLog Contents 0] IS NOT NULL  OR C.[RowLog Contents 0] IS NOT NULL  )    UPDATE @ColumnNameAndData  SET [hex_Value] = [RowLog Contents 0]  --,A.[Update]=A.[Update]+1  FROM @ColumnNameAndData A  INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],  9, 4)))) = [PAGE IDS]  AND CONVERT(INT, SUBSTRING([hex_value],  3, 2)) = [Link ID]  WHERE [System_Type_Id] IN ( 35, 34, 99 )  AND [Link ID] <> 0    UPDATE @ColumnNameAndData  SET [hex_Value] = [RowLog Contents 0]  --,A.[Update]=A.[Update]+10  FROM @ColumnNameAndData A  INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],  9, 4)))) = [PAGE IDS]  WHERE [System_Type_Id] IN ( 35, 34, 99 )  AND [Link ID] = 0    UPDATE @ColumnNameAndData  SET [hex_Value] = [RowLog Contents 0]  --,A.[Update]=A.[Update]+1  FROM @ColumnNameAndData A  INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],  15, 4)))) = [PAGE IDS]  WHERE [System_Type_Id] IN ( 35, 34, 99 )  AND [Link ID] = 0    UPDATE @ColumnNameAndData  SET [hex_value] = 0xFFFE + SUBSTRING([hex_value], 9, LEN([hex_value]))  --,[Update]=[Update]+1  WHERE [system_type_id] = 241    CREATE TABLE [#temp_Data]  (  [FieldName] VARCHAR(MAX) ,  [FieldValue] NVARCHAR(MAX) ,  [Rowlogcontents] VARBINARY(8000) ,  [Row ID] INT  )    INSERT INTO #temp_Data  SELECT NAME ,  CASE WHEN system_type_id IN ( 231, 239 )  THEN LTRIM(RTRIM(CONVERT(NVARCHAR(MAX), hex_Value))) --NVARCHAR ,NCHAR  WHEN system_type_id IN ( 167, 175 )  THEN LTRIM(RTRIM(CONVERT(VARCHAR(MAX), hex_Value))) --VARCHAR,CHAR  WHEN system_type_id IN ( 35 )  THEN LTRIM(RTRIM(CONVERT(VARCHAR(MAX), hex_Value))) --Text  WHEN system_type_id IN ( 99 )  THEN LTRIM(RTRIM(CONVERT(NVARCHAR(MAX), hex_Value))) --nText  WHEN system_type_id = 48  THEN CONVERT(VARCHAR(MAX), CONVERT(TINYINT, CONVERT(BINARY(1), REVERSE(hex_Value)))) --TINY INTEGER  WHEN system_type_id = 52  THEN CONVERT(VARCHAR(MAX), CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(hex_Value)))) --SMALL INTEGER  WHEN system_type_id = 56  THEN CONVERT(VARCHAR(MAX), CONVERT(INT, CONVERT(BINARY(4), REVERSE(hex_Value)))) -- INTEGER  WHEN system_type_id = 127  THEN CONVERT(VARCHAR(MAX), CONVERT(BIGINT, CONVERT(BINARY(8), REVERSE(hex_Value))))-- BIG INTEGER  WHEN system_type_id = 61  THEN CONVERT(VARCHAR(MAX), CONVERT(DATETIME, CONVERT(VARBINARY(8000), REVERSE(hex_Value))), 100) --DATETIME  WHEN system_type_id = 58  THEN CONVERT(VARCHAR(MAX), CONVERT(SMALLDATETIME, CONVERT(VARBINARY(8000), REVERSE(hex_Value))), 100) --SMALL DATETIME  WHEN system_type_id = 108  THEN CONVERT(VARCHAR(MAX), CONVERT(NUMERIC(38, 20), CONVERT(VARBINARY, CONVERT(VARBINARY(1), xprec)  + CONVERT(VARBINARY(1), xscale))  + CONVERT(VARBINARY(1), 0) + hex_Value)) --- NUMERIC  WHEN system_type_id = 106  THEN CONVERT(VARCHAR(MAX), CONVERT(DECIMAL(38, 20), CONVERT(VARBINARY, CONVERT(VARBINARY(1), xprec)  + CONVERT(VARBINARY(1), xscale))  + CONVERT(VARBINARY(1), 0) + hex_Value)) --- DECIMAL  WHEN system_type_id IN ( 60, 122 )  THEN CONVERT(VARCHAR(MAX), CONVERT(MONEY, CONVERT(VARBINARY(8000), REVERSE(hex_Value))), 2) --MONEY,SMALLMONEY  WHEN system_type_id = 104  THEN CONVERT(VARCHAR(MAX), CONVERT (BIT, CONVERT(BINARY(1), hex_Value)  % 2)) -- BIT  WHEN system_type_id = 62  THEN RTRIM(LTRIM(STR(CONVERT(FLOAT, SIGN(CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT))  * ( 1.0  + ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT)  & 0x000FFFFFFFFFFFFF )  * POWER(CAST(2 AS FLOAT),  -52) )  * POWER(CAST(2 AS FLOAT),  ( ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT)  & 0x7ff0000000000000 )  / EXP(52 * LOG(2))  - 1023 ))), 53,  LEN(hex_Value)))) --- FLOAT  WHEN system_type_id = 59  THEN LEFT(LTRIM(STR(CAST(SIGN(CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT))  * ( 1.0  + ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT)  & 0x007FFFFF )  * POWER(CAST(2 AS REAL), -23) )  * POWER(CAST(2 AS REAL),  ( ( ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS INT) )  & 0x7f800000 )  / EXP(23 * LOG(2))  - 127 )) AS REAL), 23,  23)), 8) --Real  WHEN system_type_id IN ( 165, 173 )  THEN ( CASE WHEN CHARINDEX(0x,  CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'VARBINARY(8000)')) = 0  THEN '0x'  ELSE ''  END ) + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'varchar(max)') -- BINARY,VARBINARY  WHEN system_type_id = 34  THEN ( CASE WHEN CHARINDEX(0x,  CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'VARBINARY(8000)')) = 0  THEN '0x'  ELSE ''  END ) + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'varchar(max)') --IMAGE  WHEN system_type_id = 36  THEN CONVERT(VARCHAR(MAX), CONVERT(UNIQUEIDENTIFIER, hex_Value)) --UNIQUEIDENTIFIER  WHEN system_type_id = 231  THEN CONVERT(VARCHAR(MAX), CONVERT(SYSNAME, hex_Value)) --SYSNAME  WHEN system_type_id = 241  THEN CONVERT(VARCHAR(MAX), CONVERT(XML, hex_Value)) --XML  WHEN system_type_id = 189  THEN ( CASE WHEN CHARINDEX(0x,  CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'VARBINARY(8000)')) = 0  THEN '0x'  ELSE ''  END ) + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'varchar(max)') --TIMESTAMP  WHEN system_type_id = 98  THEN ( CASE WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,  1)) = 56  THEN CONVERT(VARCHAR(MAX), CONVERT(INT, CONVERT(BINARY(4), REVERSE(SUBSTRING(hex_Value,  3,  LEN(hex_Value)))))) -- INTEGER  WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,  1)) = 108  THEN CONVERT(VARCHAR(MAX), CONVERT(NUMERIC(38,  20), CONVERT(VARBINARY(1), SUBSTRING(hex_Value,  3, 1))  + CONVERT(VARBINARY(1), SUBSTRING(hex_Value,  4, 1))  + CONVERT(VARBINARY(1), 0)  + SUBSTRING(hex_Value, 5,  LEN(hex_Value)))) --- NUMERIC  WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,  1)) = 167  THEN LTRIM(RTRIM(CONVERT(VARCHAR(MAX), SUBSTRING(hex_Value,  9,  LEN(hex_Value))))) --VARCHAR,CHAR  WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,  1)) = 36  THEN CONVERT(VARCHAR(MAX), CONVERT(UNIQUEIDENTIFIER, SUBSTRING(( hex_Value ),  3, 20))) --UNIQUEIDENTIFIER  WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,  1)) = 61  THEN CONVERT(VARCHAR(MAX), CONVERT(DATETIME, CONVERT(VARBINARY(8000), REVERSE(SUBSTRING(hex_Value,  3,  LEN(hex_Value))))), 100) --DATETIME  WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,  1)) = 165  THEN '0x'  + SUBSTRING(( CASE WHEN CHARINDEX(0x,  CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'VARBINARY(8000)')) = 0  THEN '0x'  ELSE ''  END )  + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',  'varchar(max)'),  11, LEN(hex_Value)) -- BINARY,VARBINARY  END )  END AS FieldValue ,  [Rowlogcontents] ,  [Row ID]  FROM @ColumnNameAndData  ORDER BY nullbit   --Create the column name in the same order to do pivot table.    DECLARE @FieldName VARCHAR(MAX)  SET @FieldName = STUFF(( SELECT ','  + CAST(QUOTENAME([Name]) AS VARCHAR(MAX))  FROM syscolumns  WHERE id = OBJECT_ID(''  + @SchemaName_n_TableName  + '')  FOR  XML PATH('')  ), 1, 1, '')  

   SET @sql = 'SELECT ' + @FieldName  + ' FROM #temp_Data PIVOT (Min([FieldValue]) FOR FieldName IN ('  + @FieldName + ')) AS pvt'  EXEC sp_executesql @sql  

 

 

 

 

-------------------结束存储过程------------------------------

执行存储过程 不加时间

EXEC Recover_Deleted_Data_Proc 'test','dbo.aa'

 

加时间段的

EXEC Recover_Deleted_Data_Proc 'test','dbo.Test_Table','2012-06-01','2012-06-30'

。。创建完存储过程,添加数据,然后删除数据,在执行存储过程。就可以看到删除的数据了。

这些数据只是显示出来。并没有插入到数据库中,剩下取数据,就行了。

看详情请点击详情链接

 

posted @ 2016-11-08 20:56  BINCHI  阅读(507)  评论(0编辑  收藏  举报