AWC 配置BOM属性对比
对比结果:
For comparing two structures and for comparing two elements within a structure, you must specify the BOMLine properties to be compared in the AWBPropertiesToCompare.BVR preference. and for comparing two parts within the product engineering BOM, you must specify the properties to be compared in the AWBPropertiesToCompare.EBOM preference.
Additionally, you can define for how long the comparison results can be retained in the Awb0CompareResultCleanupDays preference. After this time period, the comparison results are deleted.
Compare the content in structures
You compare similar engineering BOM data, such as two collaborative product engineering BOMs or two part structures, to view the differences between them. Your administrator sets up the properties that can be compared.
To compare engineering BOM data:
-
Perform the action listed in the following table depending on your task:
Task
Action
To compare two parts
Select two parts. On the results panel toolbar, click Compare > Compare Structures .
OR
Select two parts. On the primary toolbar, click View > Compare Structures .
To compare two collaborative product engineering BOMs or part structures
Select two collaborative product engineering BOMs or part structures from one of the following, and on the Primary toolbar, click View > Compare Structures :
-
Search results
-
CHANGE SUMMARY table on the History tab
-
Favorites
To compare two revisions of a part on the History tab
In the REVISION HISTORY section on the History tab, select two revisions of a part from the table. Click Compare Structures displayed above the table.
OR
In the REVISION HISTORY section on the History tab, select two revisions of a part from the table. On the Primary toolbar, click View > Compare Structures .
In the Compare panel, the parts that are unique to both structures are displayed with color bars under Results. This comparison is performed with the default comparison options.
-
-
(Optional) Change the comparison level:
-
Specify the comparison level by selecting one of the following from Options:
Comparison level
Description
All Levels
Compares the elements at every levels in the two structures. If this option is selected for very large structures, performance may be adversely affected.
Components Only
Compares only the parts that are at the lowest level (components).
Current Level
Compares only the parts that are currently displayed in the two structures. This is the default level of comparison.
Linked Assemblies or Components
Compares two structures by using accountability check. This comparison level is displayed only if Multi-Structure Foundation is available in your Teamcenter environment. Accountability check is a verification mechanism to check if all the parts in one structure have equivalent parts in the other structure. You can define your own properties for equivalence. You can also specify a set of properties for comparison.
-
Specify what you want to display in the comparison results by selecting one or more of the following options from OPTIONS > Display:
Comparison option
Description
Matched
Displays the parts that are a match in both structures.
Different
Displays the parts that differ across the two structures.
Unique in Left View
Displays the parts that are only listed in the structure displayed on the left.
Unique in Right View
Displays the parts that are only listed in the structure displayed on the right.
-
For Linked Assemblies or Components, select the Dynamic Equivalence check box.
In some cases, the occurrences that are slightly different in the two structures might not be reported as equivalent. The dynamic equivalence check reports such occurrences.
This check box is displayed only if Multi-Structure Foundation is available in your Teamcenter environment.
-
(Optional) Select the Run in Background check box to perform the comparison in the background. This is recommended when you compare all levels or only the components in large structures. You can view the results later by selecting the relevant notification from Alerts.
Note:The Run in Background check box is not displayed when you select the comparison level as Current Level.
-
Click Compare.
The comparison results are listed under Results. Clicking a part in the list highlights that part in the structure.
Comparison results are retained for a specific period. If a comparison result is older than the retention period or if a more recent result exists, the old result is automatically deleted by the system.
-
In case you closed the Compare panel and want to perform any further comparison, click Compare on the task bar (as shown in the following image) to view the Compare panel.
Our TAC servers could not reach the image source http://cnbjhd01:5000/documentation/external/PL20220523330405661/en-US/aw_collection_sc/aw/6.2/aw_collection_sc/common/graphicLibrary/structure_management/compare-in-split-view.png.
-
You can select some other parts either from the same structure or one each from the two structures displayed side-by-side for further comparison.
To reconcile the differences found in the structure, you can drag a part from one structure to another and compare them again.
【推荐】国内首个AI IDE,深度理解中文开发场景,立即下载体验Trae
【推荐】编程新体验,更懂你的AI,立即体验豆包MarsCode编程助手
【推荐】抖音旗下AI助手豆包,你的智能百科全书,全免费不限次数
【推荐】轻量又高性能的 SSH 工具 IShell:AI 加持,快人一步
· 全程不用写代码,我用AI程序员写了一个飞机大战
· DeepSeek 开源周回顾「GitHub 热点速览」
· 记一次.NET内存居高不下排查解决与启示
· 物流快递公司核心技术能力-地址解析分单基础技术分享
· .NET10 - 预览版1新功能体验(一)