Bug搬运工-CSCvm33229:Environment summary not available on COS APs

还是关于温度的问题, 

Environment summary not available on COS APs
CSCvm33229
 
Description
Symptom:
From WLC CLI if "show ap env " command is run, it does not show temperature on 3802 APs. However, from AP CLI if "show thermal" is run then the proper output is displayed.

Conditions:
Any AireOS WLC with 3802 APs.

Workaround:
At this time, there is no workaround

Further Problem Description:
From WLC CLI if "show ap env " command is run, it does not show temperature on 3802 APs.
3802 AP does not report temperature information to the WLC but in the AP, it is possible to observe the temperature with "show thermal" command:

AP output:

AP2802I#show thermal This CLI produces large dump, do you want to proceed?(y/n)y
AP thermal condition -------------------- fair
Temperature readings -------------------- A38x
CPU temp = 49 C I2C-0-4f temp = 44 C System Condtion
Alarm log --------------------------

WLC output:

(WLC3504) >show ap env AP2802I
AP Name..........................................
AP2802I AP Model......................................... AIR-AP2802I-B-K9 AP
Role.......................................... Normal
Temperature...................................... N/A
 
值得我们注意的是,对于温度的问题,思科Outdoor AP可以查看,其他室内的AP,基本都是无法查看的!