BUG搬运工:CSCun88303-CIMC Memory Leak : Can't SSH/HTTP to CIMC

Symptom:
Unable to SSH/HTTP to the CIMC of the C-series server, however the CIMC can be pinged. Also will notice the fans in the server running at a higher rate.

Generic OS installed on the server is not affected. Only out-of-band management.

===================================
Addendum:

If the affected device is an APIC running 1.0(4q) and higher, this may cause an issue where the APIC software is unable to read system-product-name and system-serial-number from SPROM. . This is sometimes seen during a planned upgrade from versions before 1.0(4q) to versions higher than 1.0(4q).

Conditions:
The timing of this can be variable, but it has been seen to occur after approximately 60 days.

Workaround:
AC power cycle the server, as in, physically removing all power from the server.

Further Problem Description:

 

Last Modified:
Jul 15,2019
Status:
Fixed
Severity:
2 Severe
Product:
(1)
Cisco Unified Computing System
Support Cases:
2306
 
Known Affected Releases:
(5)
1.4(6c)
1.5(2)
1.5(4)
1.5(7c)
2.0(3d)
 
Known Fixed Releases:
(4)
2.0(6d)
2.0(4c)
2.0(3i)
1.5(4g)