Cisco Nexus 7000 相关问题
Q. Is the FAB1 module supported with SUP2 or SUP2E?
A. Yes, supported with both supervisors.
Q. What minimum software release do I need to support SUP2 or SUP2E?
A. NX-OS 6.1
Q. Can I still run NX-OS version 6.0 on SUP1?
A. Yes.
Q. Can I upgrade SUP2 to SUP2E?
A. Yes. You would need to upgrade both the CPU and memory on board.
[8/14/2014] update: after further investigation I found that the answer is no (upgrade is not possible).
Q. I need to enable high-availability (HA), can use one SUP1 with one SUP2 in the same chassis?
A. No, for high-availability the two supervisors must be of the same type so you would need to use either SUP1/SUP1 or SUP2/SUP2.
Q. How many I/O modules can I have in a 7004?
A. Maximum of 2. The other 2 slots are reserved for the supervisors and you cannot use them for I/O modules.
Q. FAB1 or FAB2 on 7004?
A. The Nexus 7004 chassis does not actually use any FAB’s. The I/O modules are connected back to back.
Q. How many FEX’s can the Nexus 7000 support?
A. 32 FEX’s with SUP1 or SUP2; and 48 FEX’s with SUP2E.
[8/14/2014] update: 64 FEXs with SUP2E or
SUP2
Q. How many VDC’s can the Nexus 7000 support?
A. 4 VDC’s (including 1 VDC for management) with SUP1 or SUP2; and 8 + 1 (management) VDC’s with SUP2E.
Q. Which modules support FabricPath, FCoE, and FEX connectivity?
A. FabricPath is supported on all F1 and F2 modules. FCoE is supported on all F1 modules and F2 modules except on the 48 x 10GE F2 (Copper) module. FEX is supported on all F2 modules. Use this link from Cisco as a reference.
[8/14/2014] update: The F2e module supports FCoE, FEX, and FabricPath. The F3 module (12 port 40GE) supports FEX, FabricPath, FCoE, OTV, MPLS and LISP.
Q. Which modules support LISP, MPLS, and OTV?
A. All M1 and M2 modules support MPLS and OTV. LISP is supported only on the 32 x 10GE M1 module.
Q. Does the Nexus 7004 support SUP1?
A. No, the Nexus 7004 supports only SUP2 and SUP2E.
Q. Can I place an F2 module in the same VDC with F1 or M module?
A. No, the F2 module must be placed in a separate VDC so if you plan to mix F2 with F1, and M modules in the same chassis you would need a VDC license.
[8/14/2014] update: The F2e and F3 (12 port 40GE) modules can interoperate with the M-series in the same VDC.
Q. How can I upgrade from FAB1 to FAB2 modules during operation without any service disruption?
A. Yes, if you replace each module within a couple of minutes. Just make sure to replace all FAB1 with FAB2 modules within few hours. If you mix FAB1 with FAB2 modules in the same chassis for a long time, the FAB2 modules will operate in backward compatible mode and downgrade their speed to match the FAB1 modules peed. You can follow this link for step-by-step procedure for upgrading the FAB modules on the Nexus 7000.
Q. Can I use FAB1 modules in a 7009 chassis?
A. No, the Nexus 7009 uses only FAB2 modules.
Q. Does the Nexus 7000 support native Fibre Channel (FC) ports?
A. No, FC ports are not supported on the Nexus 7000. You would need either the Nexus 5500 or the MDS 9000 to get FC support.