同一台Windows机器中启动多个Memcached服务
上一篇介绍了Memcached的安装,但是如果手头上只有一台机器,又想做多节点测试咋办?
这就需要在一台机器上启动多个Memcached服务了。
假设Memcached在如下目录:C:\memcached\memcached.exe
在CMD中执行如下命令即可再安装一个Memcached服务(记得换个端口号啊!):
sc create "Memcached Server1" start= auto binPath= "C:\memcached\memcached.exe -d runservice -m 32 -p 11220 -l 127.0.0.1" DisplayName= "Memcached Server1"
下面是启动、停止、卸载该服务的命令:
sc start "Memcached Server1" //启动 sc stop "Memcached Server1" //停止 sc delete "Memcached Server1" //卸载该服务
如果你在执行命令的时候,遇到如下提示信息:
Creates a service entry in the registry and Service Database. SYNTAX: sc create [service name] [binPath= ] <option1> <option2>... CREATE OPTIONS: NOTE: The option name includes the equal sign. type= <own|share|interact|kernel|filesys|rec> (default = own) start= <boot|system|auto|demand|disabled> (default = demand) error= <normal|severe|critical|ignore> (default = normal) binPath= <BinaryPathName> group= <LoadOrderGroup> tag= <yes|no> depend= <Dependencies(separated by / (forward slash))> obj= <AccountName|ObjectName> (default = LocalSystem) DisplayName= <display name> password= <password>
请好好check下你输入的命令。
Check Point:
sc cretate命令后面带的参数比如[binPath= ]的等号后面必须有个空格,
同样,后面的其它参数比如group= , displayname=的等号后面都需要空格,
否则,sc create命令都不能成功创建服务,只会返回给你帮助信息。